03-安装机柜

目 录

安装机柜.................................................................................................................................... 1

1 概述.......................................................................................................................................... 1

1.1 机柜安装流程................................................................................................................. 1

1.2 机柜安装说明................................................................................................................. 2

2 安装支架-滑道.......................................................................................................................... 4

2.1 定位支架........................................................................................................................ 4

2.2 固定支架........................................................................................................................ 9

2.3 支架绝缘测试............................................................................................................... 10

2.4 安装滑道...................................................................................................................... 10

3 安装地脚-压板组件................................................................................................................. 12

3.1 安装机柜地脚............................................................................................................... 12

3.2 地脚-压板组件定位...................................................................................................... 13

3.3 安装膨胀螺栓............................................................................................................... 15

3.4 机柜就位和调整........................................................................................................... 16

3.5 安装压板...................................................................................................................... 17

3.6 地脚-压板组件绝缘测试............................................................................................... 17

4 安装并柜过渡底框.................................................................................................................. 18

5 固定机柜................................................................................................................................. 19

5.1 单个机柜的固定........................................................................................................... 19

5.2 机柜间的连接固定........................................................................................................ 22

6 安装机柜配件......................................................................................................................... 24

6.2 安装走线槽.................................................................................................................. 24

6.3 安装上下梁及顶盖........................................................................................................ 27

6.4 安装门.......................................................................................................................... 29

6.5 安装行列告警灯........................................................................................................... 34

6.6 安装防尘网.................................................................................................................. 36

6.7 安装过线孔盖板........................................................................................................... 37

6.8 安装地板托和盖板........................................................................................................ 39

6.9 贴装机柜标签............................................................................................................... 40

7 机柜安装检查......................................................................................................................... 41

安装机柜

1 概述

1.1 机柜安装流程

硬件安装的第一步一般是安装机柜,机柜的安装流程如图Rack-1所示:

图Rack-1 机柜安装流程图

如图Rack-1所示,机柜的安装过程如下:

(1) 根据工程环境确定机柜的安装形式

如果机柜安装在地面上,则使用地脚-压板组件;

如果机柜安装在防静电地板上,则使用支架-滑道系统;

如果在有防静电地板地机房内,拼装机柜与焊接机柜并柜安装,而且原焊接机柜的端部支架伸出了半个支架,则需要使用并柜过渡底框。

(2) 根据机柜安装形式,安装地脚-压板组件(或支架-滑道系统和并柜过渡底

框)。

(3) 将机柜就位,固定机柜与滑道或并柜过渡底框(使用地脚-压板组件时,

安装压板前机柜已经就位)。

(4) 拼装机柜调整后相互在顶部和底部连接;

(5) 机柜配件(如顶盖、门、告警灯等)的安装。此步可根据情况选择合适

的安装时机,如机柜的前后门可以在所有其它安装步骤全部完成之后再安装。

(6) 机柜全部安装完成后,要进行检查,保证安装牢固、准确、可靠。

1.2 机柜安装说明

1. 机柜的种类

C&C08数字程控交换系统中,机柜主要有三种:

(1) 普通交换机柜,采用拼装机柜,不带侧门时,其机柜尺寸为800(宽)×

550(深)×2100(高),其中高度包含顶盖的高度;

(2) 直流配电柜,也是采用拼装机柜,其尺寸与普通的交换机柜完全相同;

(3) B68服务器机柜,其尺寸为600(宽)×800(深)×2100(高),其中

高度包含顶盖的高度;B68服务器机柜采用嵌入式的侧门,装上侧门以后机柜的宽度并不增加。

需要注意的是,B68服务器机柜与其他机柜的机柜尺寸不同,在安装地脚-压板组件或支架-滑道系统时应特别注意。

说明:

B68-21机柜有两种,一种是B68-21交换设备机柜,另一种为B68服务器机柜。两种机柜的外形尺寸完全一样,只是机架有区别。

2. 机柜的安装位置

(1) 安装依据

安装人员摆放设备有以下两个依据:

局方所提供《工程设计文件》中的“机房平面图”是施工的重要依据;

华为技术有限公司所提供的工程设计图纸中的机柜板位图也是施工的重要依据。

安装人员需要根据工程设计图纸,对照机房平面图,按照机柜板位图上确定各个机柜的位置,并据此摆放机柜。

(2) 机柜摆放原则

为了设备安装过程和维护过程中开、关门及维护方便,根据C&C08 数字程控交换系统的工艺结构特性,对机房中的设备的摆放提出以下要求(工程设计应符合这些要求):

机柜列前至少留出1.2~1.5米的距离;

一排机柜正面与另一排机柜正面之间距离不小于1.5米;

机柜侧面与墙的距离不小于0.8米;

机柜正面与墙距离为1米;

机房应留有不小于1米宽的通道。

(3) C&C08交换设备的一般摆放顺序

C&C08交换设备的AM/CM机柜安装在同一个机房,一般单排摆放,如图Rack-2所示: L I M 3L I M 2L I M 1A M S R M S P M 1S P M 2S P M 3

图Rack-2 单排摆放时机柜安排图

当确实需要分双排摆放时,必须将AM 机柜和LIM 机柜摆放在一排,其余机柜摆放在另一排,AM 与SRM 对正放置,根据中继电缆的走线方向将机柜摆放为如图Rack-3中A 、B 两种形式之一。

A

B

图Rack-3 机柜双排摆放时机柜安排图

BAM 机柜可以与交换设备机柜摆放在同一排,也可以单独摆放为一排。 直流配电柜一般与交换设备摆放在同一排。

2 安装支架-滑道

当设备安装地点的地面铺设有防静电地板的时候,机柜使用支架-滑道系统固定。

安装支架-滑道的一般过程是:

(1) 定位支架;

(2) 固定支架;

(3) 支架绝缘测试;

(4) 安装滑道。

2.1 定位支架

1. 划线

根据施工平面设计图给定的基准尺寸和支架尺寸确定支架安装位置。

一排N 个拼装机柜(包括交换设备机柜和直流配电柜)需要N +1个支架,其中两端的支架为端部支架,中间的支架为共用支架。

BAM 服务器机柜与拼装机柜安装在同一排时,BAM 机柜使用两个P800支架,其他机柜的安装与一排全是拼装机柜时相同(将与BAM 服务器机柜相邻的机柜看作第一个机柜)。画线时,应考虑侧门的厚度(BAM 服务器机柜和相邻的拼装机柜都安装侧门,BAM 服务器侧门为嵌入式,不用考虑厚度,拼装机柜侧门厚度为40mm )。

图Rack-4~图Rack-7给出了拼装机柜(包括直流配电柜)的支架孔位图。图Rack-4为支架安装孔位图; 图Rack-5为单个机柜安装孔位图;图Rack-6为两个机柜安装孔位图;图Rack-7为多个和多排机柜安装孔位图。 确定支架安装位置可以有两种方法:

(1) 参考图Rack-4~图Rack-7,根据施工平面设计图给定的基准尺寸,测量

出每排第一个支架(为端部支架)的支架位置及孔位,从第一个支架孔位出发,用墨斗划出两条平行于基准且间距为460mm 的直线,以第一个支架孔位为基准点,逐个划出其它支架的安装孔。为防止出现错误,在所有孔位线划好后应进行重复测量,核对尺寸的准确无误。

(2) 第二种方法是,参考图Rack-7,将所有的支架按照图中的位置摆放在地

板上,测量各支架的位置无误后,将各支架的位置以及所有的孔位作上标记。

划线和定位是机柜安装的基础,一定要注意准确性,否则会给以后的工作带来极大不便。

注意:

(1) 施工平面设计图中标注的尺寸一般是以机柜的边缘为基准。因此支架定位时,需要注意支架边缘与机柜边缘的差别。

(2) 如施工平面设计图要求一排拼装机柜的侧面与墙壁距离为800mm ,则端部支架的边缘应该与墙相距840mm 。因为安装侧门之前,机柜侧面边缘应该与支架边缘对齐,装上侧门(厚40mm )后,机柜边缘与支架边缘的距离为40mm ,与墙壁距离为800mm 。

(3) 同样机柜的正面(或背面)与墙壁的之间距离与支架端部与墙壁之间的距离也是有差别的。

BAM 服务器机柜采用B68服务器机柜,其机柜尺寸与拼装机柜不同(且机柜的宽度与侧门无关),因此支架的尺寸和孔位也与拼装机柜不同。安装时应特别注意!

B68服务器机柜的支架安装孔位图如图Rack-8所示。

图Rack-4 支架安装孔位图

图Rack-5 单个机柜安装孔位图

图Rack-6 两个机柜安装孔位图

图Rack-7 多个和多排机柜安装孔位图

图Rack-8 单个BAM 服务器机柜(B68服务器机柜)安装孔位图

2. 钻孔

在地面膨胀螺栓孔标记处,选择Ф14或Ф16的钻头打孔,孔深应保证膨胀螺栓的膨胀管刚好能全部放入孔内。

使用冲击钻(或电锤)打孔时要保证钻头与地面保持垂直,双手紧握钻柄,垂直向下用力,不要摇晃,以免破坏地面、加大孔径或使孔倾斜。

当钻头选择Ф14时,如果孔径小,则可以通过技术处理加大孔径。

如果地面特别坚固平滑,钻头不易定位,可先用样冲在孔位上凿一个凹坑,帮助钻头定位。

钻孔时,使用吸尘器,吸净灰尘,每天下班前要清除机房一切垃圾,做到“日清”。

划线和打孔是设备硬件安装的基础性工作,如果准确性不高会给以后工作带来极大不便,所以保证它们的质量是保证整个工程质量的必备条件。

2.2 固定支架

1. 安装膨胀螺栓

安装前,使用吸尘器将所有孔位内部、外部的灰尘清除干净,再对孔距测量,并放置支架看是否与孔位一一对应,对于误差较大的孔先不要安装膨胀螺栓,而要重新定位、打孔。

取下膨胀螺栓上的垫圈、螺母,将膨胀螺栓杆和膨胀管垂直放入孔中,用橡胶锤直接敲打膨胀螺栓,直到将膨胀螺栓的膨胀管全部敲入地面。

2. 调节支架高度

根据测量的地板高度值,参照支架上防静电地板高度的丝印标记,调节所有支架至预定高度,并用力矩扳手紧固高度锁定螺栓至45Nm 。此时螺栓紧固顺序应遵循“先中间,后两侧”的原则,即先分别紧固中间的两个高度锁定螺栓,再紧固两侧共四个高度锁定螺栓。见图Rack-9:

图Rack-9 支架与地面连接示意图

3. 支架的安装与固定

清洁地面和支架表面,按图Rack-9所示装入支架绝缘垫与支架绝缘套,将支架安装孔对正相应的膨胀螺栓,用螺母、垫圈将支架固定于地面,紧固力矩应达到45Nm 。

固定支架用的螺母应依次交叉紧固,以减小螺栓与支架间的应力,也便于在 安装过程中对支架进行校正,其它支架也按以上方法安装。

通过在支架底部加绝缘垫,膨胀螺栓处加绝缘套,使整套设备在未接地线之前,不与大地接通,能有效地满足绝缘要求。

2.3 支架绝缘测试

2.4 安装滑道调万用表至电阻档,用万用表的两个测量头分别与支架和拉爆膨胀螺栓接触,测量其间电阻。若电路呈现断路状态,继续下步安装。否则说明支架与地没有绝缘,此时检查是否漏装支架绝缘套或支架绝缘垫,或绝缘零件是 否损坏。重新进行支架的安装与固定,再进行绝缘测试。

拼装机柜的滑道每根长度为1600mm 。如果需要,现场将一根滑道锯断,成为两根长度为800mm 的滑道。

B68服务器机柜的滑道每根长度为1200mm ,同样可以现场锯断成为两根长度为600mm 的滑道。

滑道的安装过程如下:

1. 预装方形螺母

在安装滑道前,应将固定地板托组件及固定滑道用的方形螺母(两者相同) 预先装入滑道的下槽道,每台机柜下的每侧滑道中应装入五个方形螺母,其中中间三个留做固定地板托组件用,两侧的两个是滑道与支架固定时用。否则,滑道装好后,方形螺母就不能装入,滑道与支架的固定如图Rack-10所示。 每个机柜配有六套地板托组件,在机柜下两侧的滑道中各装入三套。

图Rack-10 滑道与支架固定及水平调节示意图

2. 调平、固定滑道

用方螺母、平垫、弹垫和M12×20螺栓将滑道固定于支架上,如图Rack-10所示。

首先旋上装有弹垫、平垫的M12×20螺栓(先不拧紧,螺栓不掉下即可),然后把螺栓依次卡入支架 孔内,然后用水平尺对滑道各段测量(横向与纵向同时测量),可通过增减垫片调节水平,如果水平则依次拧紧各螺栓,然后再进行水平测试,如图Rack-11所示。如果不水平,拧松螺栓,继续增减垫片,直到滑道水平。滑道安装完毕后,应达到以下几点要求:

(1) 单独的一根滑道纵向必须是水平的;

(2) 平行的两条滑道横向必须是水平的;

(3) 平行的两根滑道槽中心点测量值为460mm ±1mm ;

(4) 如有多条滑道对接安装时,用拉直的细线进行校正,必须保证多条滑道

在一条直线上。两条滑道衔接处应没有缝隙,没有高低不平现象。

图Rack-11 滑道水平测量示意图

3 安装地脚-压板组件

机柜在水泥地面的机房内安装时,采用地脚-压板组件将机柜固定在地面上。 安装地脚-压板组件的一般过程是:

(1) 安装地脚;

(2) 地脚-压板组件定位;

(3) 安装膨胀螺栓;

(4) 机柜就位;

(5) 安装压板;

(6) 地脚-压板绝缘测试。

3.1 安装机柜地脚

在将机柜摆放到设计位置之前,需要先完成机柜地脚的安装,具体安装方法见图Rack-12,安装时注意保证地脚的底平面和拼装机柜的底面的距离为55mm 。

置。

每个机柜使用4个地脚和压板。

图Rack-13为单个机柜安装孔和地脚位置图;图Rack-14为多个和多排机柜安装孔和地脚位置图。

划线的方法是:

参考图Rack-13和图Rack-14,根据施工平面设计图给定的基准尺寸, 测量出每排第一个机柜的地脚位置及压板的安装孔位。从第一个机柜的地脚位置出发,用墨斗划出两条平行于基准且间距为460mm 的直线,以第一个机柜的地脚位置为基准点,逐个划 出其它支架的安装孔。为防止出现错误,在所有位置及孔位线划好后应进行重复测量,核对尺寸的准确无误。

BAM 服务器机柜采用B68服务器机柜,其机柜尺寸与拼装机柜不同,因此地脚和压板地安装孔位的尺寸也与拼装机柜不同。安装时应特别注意!

BAM 服务器机柜和交换设备机柜同一排摆放且相邻时,画线时应特别考虑交换设备侧门的厚度。

BAM 服务器机柜的安装孔和地脚位置图如图Rack-15所示。

图Rack-13 单个机柜安装孔和地脚位置标记图

图Rack-14 多个和多排机柜安装孔和地脚位置标记图

⑴ 机柜边缘线 ⑵ 机柜地脚位置标记(4-φ50)

⑶ 使用M12膨胀螺栓 ⑷ 机柜门板边缘线 ⑸ 内墙或参考体

图Rack-15 B68服务器机柜地脚孔位布置图

2. 钻孔

在地面膨胀螺栓孔标记处,选择Ф14或Ф16的钻头打孔,孔深应保证膨胀螺栓的膨胀管刚好能全部放入孔内。

使用冲击钻(或电锤)打孔时要保证钻头与地面保持垂直,双手紧握钻柄, 垂直向下用力,不要摇晃,以免破坏地面、加大孔径或使孔倾斜。

当选择Ф14的钻头时,如果孔径稍小,可以通过技术处理加大孔径。

如果地面特别坚固平滑,钻头不易定位,可先用样冲在孔位上凿一个凹坑,帮助钻头定位。

钻孔时,使用吸尘器,吸净灰尘,每天下班前要清除机房一切垃圾,做到“日清”。

划线和打孔是设备硬件安装的基础性工作,如果准确性不高会给以后工作带来极大不便,所以保证它们的质量是保证整个工程质量的必备条件。

3.3 安装膨胀螺栓

取下膨胀螺栓上的垫圈、螺母,将膨胀螺栓杆和膨胀管垂直放入孔中,用橡 胶锤直接敲打膨胀螺栓,直到将膨胀螺栓的膨胀管全部敲入地面。

3.4 机柜就位和调整

在机柜就位之前,机柜地脚应已安装好。

(1) 抬起机柜就位,将机柜的四个地脚对正地面上四个相应的地脚位置标记,

如图Rack-16所示。

(2) 调整水平。

一排拼装机柜就位后,从左边第一个拼装机柜开始,旋转地脚的调平螺母调整拼装机柜与地面的距离,使同一排的拼装机柜高度相同,且保持水平。要求机柜的垂直度偏差不大于3mm ,从左至右依次调整每一个机柜。相同的方法再调整第二排、第三排机柜。

3.5 安装压板

机柜就位后,使用压板将装有地脚的机柜固定在地面上。

在地面的膨胀螺栓杆上自下而上依次穿上绝缘垫板、压板、支架绝缘套、垫 片,压板的开口处压在地脚上,用螺母拧紧,如图Rack-17所示。

(1)M16地脚 (2)螺母M16 (3)螺母M12 (4)弹垫12

(5)大平垫12 (6)支架绝缘套 (7)压板 (8)膨胀螺栓M12×80

(9)绝缘垫板 (10)膨胀管

图Rack-17 地脚-压板组件组成示意图

3.6 地脚-压板组件绝缘测试

调万用表至电阻档,用万用表的两个测量头分别与地脚和拉爆膨胀螺栓接触,测量其间电阻。若电路呈现断路状态,继续下步安装。否则说明地脚与地没有绝缘,此时检查是否漏装支架绝缘套或绝缘垫板,或绝缘零件是否损坏。并重新安装压板,然后再重新进行绝缘测试。

至此,地脚-压板组件和机柜就已经安装完成了,在进行下一步安装工作之前,应该注意将机房整理、清洁一遍,以保证下面安装工作的环境。

4 安装并柜过渡底框

如果拼装机柜与原有焊接机柜要并柜安装,且焊接机柜的支架伸出机柜(原焊接机柜的安装规范要求:考虑到扩容方便,一排机柜的最末端的支架应伸出机柜,即机柜未装侧门时,机柜边缘与最末端支架的中轴线对齐),就需要用并柜过渡底框进行过渡安装。(如果是新装一排机柜,或者拼装机柜与焊接机柜并柜安装,但焊接机柜的最后一个支架并不伸出机柜,则使用支架-滑道系统即可)。

并柜过渡底框的安装过程是:

(1) 划线、钻孔、安装膨胀螺丝;

(2) 安装支架。包括调节支架高度、安装支架、支架绝缘测试;

(3) 调平并固定并柜过渡底框。

其中需要注意的是划线和安装并柜过渡底框,其他各项安装过程与支架-滑道系统的安装完全一致。

下面主要说明划线和固定并柜过渡底框的方法:

1. 划线

以原有的机柜边缘为基准,按图Rack-18划线。

图Rack-18 并柜过渡底框安装孔位图

2. 固定并柜过渡底框

如图Rack-19所示,将并柜过渡底框放在原有支架和新安装的支架上,用M12×30 螺栓、弹垫、平圈将并柜过渡底框固定在支架上。

5 固定机柜

5.1 单个机柜的固定

单个机柜的固定方法,根据机柜安装方式的不同,分为三种情况:

(1) 使用支架-滑道系统安装(有防静电地板);

(2) 使用地脚-压板系统安装(无防静电地板);

(3) 使用并柜过渡底框安装(拼装机柜与焊接机柜并柜安装)。 读者和安装人员可根据实际情况选择阅读。

1. 采用支架-滑道系统时的机柜固定

使用M12×20螺栓、弹垫、平垫、方螺母将机柜的底脚与滑道固定,如图Rack-21所示。具体过程如下:

a) 逐个把拼装机柜抬上滑道,并将拼装机柜支架四个固定孔和滑道的

固定槽对齐,方螺母从滑道的槽道口装入并与拼装机柜、支架的固定孔对正,然后使用螺栓固定。

b) 一排拼装机柜就位后,先紧固最外面一台拼装机柜和滑道间的连接,

并调整好水平度(可以通过在机柜底脚和滑道之间加装垫片来调整水平),保证机柜的垂直度偏差不大于3mm 。 以第一台拼装机柜为基准,从左至右依次调整并紧固每一个拼装机柜。相同的方法再紧固第二排、第三排机柜。

先安装机柜的地脚,再用压板将装有地脚的机柜固定在地面上。 地脚-压板系统的安装方法前面已经介绍,这里不再赘述。 3. 采用并柜过渡底框时的机柜固定

采用并柜过渡底框时机柜的固定方法与采用支架-滑道系统时机柜的固定方法类似,但此时机柜不需要安装底脚,而是直接固定在过渡底框上。

将拼装机柜抬上并柜过渡底框,并将拼装机柜支架四个固定孔和底框的固定孔对齐,调整机柜水平后使用M12×20螺栓固定。

5.2 机柜间的连接固定

所有机柜就位并固定后,机柜应平齐并拢。为了使机柜更加牢固,单个机柜就位并固定后,要将相邻的机柜相互间连接固定,使一排机柜成为一个整体。 拼装机柜每个侧面的顶部和底部各有两个侧面连接孔。所有机柜调整水平后,相邻机柜的侧面连接孔是对齐的。

用螺栓穿过相邻拼装机柜的侧面连接孔(共4个,顶部2个,底部2个),再用平垫、弹垫和螺母将两个拼装机柜连接起来。

相邻拼装机柜的顶盖之间,顶盖与侧门之间应用M3×10的螺钉连接并紧固。 拼装机柜间的连接如图Rack-22所示。

在使用工具过程中要注意保护机柜,以免工具碰伤、划伤机柜。

Rack-23

6 安装机柜配件

1. 机柜的配件主要包括 (1) 走线槽;

(2) 机柜的上梁、下梁和顶盖;

(3) 机柜的前后门和侧门(包括侧门附件上拉板、中拉板和下拉板); (4) 机柜行列告警灯; (5) 防尘网;

(6) 地板托(有防静电地板时); (7) 机柜标签。

2. 在硬件安装过程中,可以根据实际情况选择上述配件的安装时机

(1) 机柜的上梁和顶盖以及机柜行列告警灯可以在固定机柜之前安装,也可

以在机柜固定以后安装; (2) 下梁一般在机柜固定以后安装;

(3) 机柜的前后门和侧门一般在机柜电缆安装完成后再安装(若在电缆安装

前就安装机柜门,可能会对电缆安装有影响); (4) 机柜的防尘网、地板托、机柜标签等一般在最后安装。

6.2 安装走线槽

走线槽有两种:

(1) 同一行交换设备机柜顶部的走线槽,用于承托电源线;

(2) 拼装机柜行与行之间的走线槽,用于机柜行与行之间HW 线、光纤的走

线。线槽两侧应紧贴机柜的上出线口。线槽的长度可调,两边线槽可以抽动,当两行机柜之间的距离为1150~1550mm时,都能满足要求。 1. 安装柜顶走线槽

交换设备机柜的顶部留有安装孔,用来安装走线槽,其结构尺寸如图Rack-23所示。

2. 安装行间走线槽

如果机柜采用双排摆放,则需要安装行间走线槽。行间走线槽一般安装在两排机柜的端部机柜的顶上。

行间的走线槽有开放式和封闭式两种。

开放式线槽使用托架固定。安装时使用M8×25的螺钉固定在机柜的顶部,如图图Rack-25所示。

图Rack-26 封闭式行间走线槽安装完成示意图

6.3 安装上下梁及顶盖

1. 安装上、下梁

每个拼装机柜(交换设备机柜和直流分配柜)的前后都有上下梁。其安装顺序如下:

(1) 将上梁安装于拼装机柜的上部,前后各一个; (2) 将下梁安装于拼装机柜的底部,前后各一个。 上下梁及顶盖的安装参见图Rack-27:

图Rack-27 上梁和下梁的安装示意图

说明:

B68服务器机柜的上梁与顶盖连为一体,其安装方法与拼装机柜类似。

2. 安装顶盖

机柜顶部有前顶盖和后顶盖,既美观又可起到防止异物掉入的作用。顶盖安装过程如下:

(1) 将前后顶盖固定在机柜的上梁上,如图Rack-28所示; (2) 将一行机柜中相邻机柜的前后顶盖用螺钉相互连接起来; (3) 每行机柜侧面的两个机柜上的顶盖要与侧门用螺钉连接。

6.4 安装门机柜门分为前后门和侧门。

每个机柜的前后各有左右两扇对开的柜门,使用插销安装在机柜上; 在一排机柜的两侧需要安装侧门。拼装机柜的侧门使用侧门附件上拉板、中拉板和下拉板固定在机柜上;B68服务器机柜的侧门直接固定在机柜上。 1. 安装上拉板、中拉板和下拉板

拼装机柜的侧门使用上拉板、中拉板和下拉板固定在机柜上,安装侧门首先要安装上拉板、中拉板和下拉板。

B68服务器机柜的侧门安装不需要此步骤。

这三套附件的安装顺序如下,参看图Rack-29。 (1) 将上拉板安装于拼装机柜侧面的上部; (2) 将中拉板安装于拼装机柜侧面的中部; (3) 将下拉板安装于拼装机柜侧面的下部。

Rack-31

2. 安装侧门 (1) 拼装机柜

安装侧门时先注意下固定边与机柜下围框对齐,更容易装配。固定好上下共6个螺钉即可,侧门安装如图Rack-31所示:

3. 安装前后门

每个机柜前后各有左右两扇门,左右门的安装方法相同,左门安装方法如下: (1) 将门的右下端孔与拼装机柜上的销对准,将左门下端装上。

(2) 用手拉下左门上端的三角形钩销,将门上的孔与拼装机柜上的孔对齐,

松开手,在弹簧力作用下钩销往上复位将门安装在拼装机柜上。 (3) 用接地线将机柜门和机柜可靠连接。

B68服务器机柜的左右门的尺寸与普通拼装机柜不同,但是其安装方法相同。 前后门的安装示意图见图Rack-32。

说明:

6.5 安装行列告警灯

机柜行列告警灯位于机柜的顶盖上或侧门上部。通过行列告警灯, 可以迅速发现产生告警的机柜。

行列告警灯分为行灯和列灯,包括红、黄、绿三个告警灯,分别用于指示一级告警、二三级告警和四级告警。

行灯安装在一行机柜两端的侧门上部,用于向维护人员指示是哪一行机柜的设备发生了告警;

列灯安装在每个机柜的前顶盖上,向维护人员指示是哪一个机柜的设备发生了告警。

行列告警灯的安装位置如图Rack-33所示

机柜顶盖

红黄绿灯灯灯

红黄绿

机柜顶盖

列告警

C&C08

灯灯灯

C&C08

红黄绿灯灯灯

行告警灯

侧门

图Rack-33 行、列告警灯示意图

行列告警灯的安装过程如下:

(1) 将告警灯按照图Rack-33的位置顺序安装到机柜的前顶盖和侧门上。 (2) 连接行列灯控制线

每个交换机柜都配有一块CB01AMD 板,用于处理风扇告警和驱动行列告警灯,该板发货时已安装在机柜顶部配电盒中。现场需要用行列灯控制线连接CB01AMD 板和行列告警灯。

行列灯控制线一端为一个4PIN 插头,接AMD 板;另一端为六个端子,包括红、黄、绿三个端子和三个黑色端子,一个黑色端子与一个彩色端子为一组,连接相应颜色的告警灯。

安装时,4PIN 插头插到AMD 板上的J6(行灯)或J7(列灯);将对应颜色的端子安装到行列灯的一个电源端子上,黑色端子连接到行列灯的另一个电源端子上。 (3) 安装行灯级连线

行灯级连线的两端均为4PIN 插头。互连两个机柜时,一端接在左边机柜AMD 板的J5上,另一端接在右边机柜的J4上。

6.6 安装防尘网

机柜的风扇箱安装在机柜内的底部,风扇单元安装在机柜内的顶部,风从机柜底部通风孔进入,为防止灰尘或其他小的异物被风带入机柜,在风扇箱内的底部安装有防尘网,每个风扇箱里并列有两块。防尘网可定期取出清洗或更换。

防尘网的安装过程如下:

(1) 拧松风扇箱下部的防尘网箱面板上的紧固螺丝,抽出防尘网箱; (2) 并排插入两块防尘网;

(3) 将防尘网箱推入机柜,拧紧面板上的紧固螺丝。 防尘网的安装如图Rack-34、图Rack-35所示。

注意:

(1) 交换设备机柜、B68服务器机柜的底部都要安装防尘网。B68机柜的侧门也安装有防尘网。

(2) 由于运输的颠簸,每一台机柜在机房安装好后,要抽出风扇箱内下部的防尘网,看两块防尘网是否有挪位、重叠现象,如果有的话,一定要将其复原,保证防尘效果。

6.7 安装过线孔盖板

在拼装机柜的顶部和底部有光纤和中继线等过线孔,光纤和中继线等从过线孔过线后,为了防止老鼠、灰尘或杂物进入机柜,过线孔除了光纤或电缆外的间隙要用长盖板或短盖板盖上,如图Rack-36所示。

在有些情况下,电源线要从底部引入,在拼装机柜两侧的顶部和底部各有6个电源线过线孔,供电源线从机柜底部进入。拼装机柜侧面过线孔结构示意图见图Rack-37。

注意:

B68服务器机柜的顶部和底部都有过线孔。过线孔用的是塑料盖板。线缆要从过线孔穿过时,用小刀在塑料盖板上划出所需的孔即可。

用它来支撑机柜周边的防静电地板。安装盖板的目的一 是在支架和防静电地板之间起绝缘作用,二是遮挡机柜底部的缝隙。

安装地板托和盖板、复原地板等工作一般在硬件安装的最后进行。 1. 固定地板托

根据需要确定地板托的位置,先用M12×20螺栓、平垫、弹垫将固定弯板固 定在滑道上(滑道内已经预装了方螺母,见本章“2.4 安装滑道”)。 2. 安装盖板和活动弯板

用M8×30螺栓、平垫、弹垫、绝缘垫将盖板、活动弯板固定在固定弯板上,地板托的固定及安装盖板和活动弯板如图Rack-38所示。

图Rack-38 地板托安装图

3. 确定活动弯板位置

拧松图Rack-38所示地板托组件中的M8×30螺栓,上下移动活动弯板,使活动弯板的上平面与防静电地板的下平面等高,拧紧螺栓。

4. 地板托绝缘测试

调万用表至电阻档,用万用表的两个测量头分别与支架和地板托组件中的活 动弯板接触,测量其间电阻。若电路呈现断路状态,继续下步安装。否则说 明支架与地板没有绝缘,此时拆开地板托组件检查其中是否漏装绝缘板和绝缘垫,或绝缘板、绝缘垫被损坏。重复前面第2、3步,然后重新进行地板托绝缘测试。

5. 复原地板

根据现场实际情况,切割机柜周边的防静电地板,并复原地板。

6.9 贴装机柜标签

1. 机柜标签的外形及含义

机柜标签可表示机柜的物理位置,可分为行标签和列标签。行标签为圆形,标号为大写字母;列标签为方形,标号为数字。机柜标签如图Rack-39所示:

图Rack-39 机柜标签示意图

2. 机柜的编号

机柜标签可表示机柜的物理位置,给维护人员提供准确的设备位置标志信息。维护人员根据这些标志可以很快找到自己所关心的设备,机柜上标签的具体编号是和配置数据中的位置描述值一一对应的。

通常情况下当机柜为一行布置时,靠近主走道的第一台机柜列号标签为“00”,贴在机柜上围框上;第二台机柜列号标签为“01”,第三台机柜列号标签为“02”,以此类推第十二台列号标签为“11”;机柜两端的侧板上贴上行号标签为“(A)”。

当机柜为多行布置时,管理/通讯模块机柜通常排在靠近控制室的第一行,机柜两端的侧板上贴上行号标签“(A)”;第二行行号标签为“(B)”;第三行行号标签为“(C)”。

3. 标签贴装在机柜上的位置

行列标签的贴装位置在机柜上有相应的标记:

(1) 行号的安装位置

行号标签为圆形,安装在侧门上。

(2) 架号的安装位置

架号标签为长方形,安装在拼装机柜的上横梁上。

至此,整个机柜安装完毕。

7 机柜安装检查

机柜安装完毕后,应注意检查以确保安装正确。检查时要注意以下事项:

(1) 机柜连接后,要求做到稳立不动,整齐美观。

(2) 机柜的垂直偏差度应不大于3mm 。

(3) 四面走道侧的机柜面板应全部装上,并对齐成直线,误差不大于5mm 。

相邻拼装机柜应紧密靠拢,高度一致,整列机面应在同一平面上,无凹凸现象。

(4) 各种螺钉要全部拧紧,但不可扭伤螺纹和螺帽。

(5) 拼装机柜上的各零件不得脱落或碰坏,连线不能碰伤、碰断。各种标志

牌应正确、清晰、齐全。

(6) 要清洁机柜,使安装过程中手触摸的痕迹不被看见。

(7) 使用工具时要注意保护机柜,不使机柜表面受损。

(8) 机柜安装完毕后,用卷尺测量每台机柜与参照物上、中、下端的尺寸,

尺寸应一致,机柜两排之间的两端及中间测量尺寸也应相同。

目 录

安装机柜.................................................................................................................................... 1

1 概述.......................................................................................................................................... 1

1.1 机柜安装流程................................................................................................................. 1

1.2 机柜安装说明................................................................................................................. 2

2 安装支架-滑道.......................................................................................................................... 4

2.1 定位支架........................................................................................................................ 4

2.2 固定支架........................................................................................................................ 9

2.3 支架绝缘测试............................................................................................................... 10

2.4 安装滑道...................................................................................................................... 10

3 安装地脚-压板组件................................................................................................................. 12

3.1 安装机柜地脚............................................................................................................... 12

3.2 地脚-压板组件定位...................................................................................................... 13

3.3 安装膨胀螺栓............................................................................................................... 15

3.4 机柜就位和调整........................................................................................................... 16

3.5 安装压板...................................................................................................................... 17

3.6 地脚-压板组件绝缘测试............................................................................................... 17

4 安装并柜过渡底框.................................................................................................................. 18

5 固定机柜................................................................................................................................. 19

5.1 单个机柜的固定........................................................................................................... 19

5.2 机柜间的连接固定........................................................................................................ 22

6 安装机柜配件......................................................................................................................... 24

6.2 安装走线槽.................................................................................................................. 24

6.3 安装上下梁及顶盖........................................................................................................ 27

6.4 安装门.......................................................................................................................... 29

6.5 安装行列告警灯........................................................................................................... 34

6.6 安装防尘网.................................................................................................................. 36

6.7 安装过线孔盖板........................................................................................................... 37

6.8 安装地板托和盖板........................................................................................................ 39

6.9 贴装机柜标签............................................................................................................... 40

7 机柜安装检查......................................................................................................................... 41

安装机柜

1 概述

1.1 机柜安装流程

硬件安装的第一步一般是安装机柜,机柜的安装流程如图Rack-1所示:

图Rack-1 机柜安装流程图

如图Rack-1所示,机柜的安装过程如下:

(1) 根据工程环境确定机柜的安装形式

如果机柜安装在地面上,则使用地脚-压板组件;

如果机柜安装在防静电地板上,则使用支架-滑道系统;

如果在有防静电地板地机房内,拼装机柜与焊接机柜并柜安装,而且原焊接机柜的端部支架伸出了半个支架,则需要使用并柜过渡底框。

(2) 根据机柜安装形式,安装地脚-压板组件(或支架-滑道系统和并柜过渡底

框)。

(3) 将机柜就位,固定机柜与滑道或并柜过渡底框(使用地脚-压板组件时,

安装压板前机柜已经就位)。

(4) 拼装机柜调整后相互在顶部和底部连接;

(5) 机柜配件(如顶盖、门、告警灯等)的安装。此步可根据情况选择合适

的安装时机,如机柜的前后门可以在所有其它安装步骤全部完成之后再安装。

(6) 机柜全部安装完成后,要进行检查,保证安装牢固、准确、可靠。

1.2 机柜安装说明

1. 机柜的种类

C&C08数字程控交换系统中,机柜主要有三种:

(1) 普通交换机柜,采用拼装机柜,不带侧门时,其机柜尺寸为800(宽)×

550(深)×2100(高),其中高度包含顶盖的高度;

(2) 直流配电柜,也是采用拼装机柜,其尺寸与普通的交换机柜完全相同;

(3) B68服务器机柜,其尺寸为600(宽)×800(深)×2100(高),其中

高度包含顶盖的高度;B68服务器机柜采用嵌入式的侧门,装上侧门以后机柜的宽度并不增加。

需要注意的是,B68服务器机柜与其他机柜的机柜尺寸不同,在安装地脚-压板组件或支架-滑道系统时应特别注意。

说明:

B68-21机柜有两种,一种是B68-21交换设备机柜,另一种为B68服务器机柜。两种机柜的外形尺寸完全一样,只是机架有区别。

2. 机柜的安装位置

(1) 安装依据

安装人员摆放设备有以下两个依据:

局方所提供《工程设计文件》中的“机房平面图”是施工的重要依据;

华为技术有限公司所提供的工程设计图纸中的机柜板位图也是施工的重要依据。

安装人员需要根据工程设计图纸,对照机房平面图,按照机柜板位图上确定各个机柜的位置,并据此摆放机柜。

(2) 机柜摆放原则

为了设备安装过程和维护过程中开、关门及维护方便,根据C&C08 数字程控交换系统的工艺结构特性,对机房中的设备的摆放提出以下要求(工程设计应符合这些要求):

机柜列前至少留出1.2~1.5米的距离;

一排机柜正面与另一排机柜正面之间距离不小于1.5米;

机柜侧面与墙的距离不小于0.8米;

机柜正面与墙距离为1米;

机房应留有不小于1米宽的通道。

(3) C&C08交换设备的一般摆放顺序

C&C08交换设备的AM/CM机柜安装在同一个机房,一般单排摆放,如图Rack-2所示: L I M 3L I M 2L I M 1A M S R M S P M 1S P M 2S P M 3

图Rack-2 单排摆放时机柜安排图

当确实需要分双排摆放时,必须将AM 机柜和LIM 机柜摆放在一排,其余机柜摆放在另一排,AM 与SRM 对正放置,根据中继电缆的走线方向将机柜摆放为如图Rack-3中A 、B 两种形式之一。

A

B

图Rack-3 机柜双排摆放时机柜安排图

BAM 机柜可以与交换设备机柜摆放在同一排,也可以单独摆放为一排。 直流配电柜一般与交换设备摆放在同一排。

2 安装支架-滑道

当设备安装地点的地面铺设有防静电地板的时候,机柜使用支架-滑道系统固定。

安装支架-滑道的一般过程是:

(1) 定位支架;

(2) 固定支架;

(3) 支架绝缘测试;

(4) 安装滑道。

2.1 定位支架

1. 划线

根据施工平面设计图给定的基准尺寸和支架尺寸确定支架安装位置。

一排N 个拼装机柜(包括交换设备机柜和直流配电柜)需要N +1个支架,其中两端的支架为端部支架,中间的支架为共用支架。

BAM 服务器机柜与拼装机柜安装在同一排时,BAM 机柜使用两个P800支架,其他机柜的安装与一排全是拼装机柜时相同(将与BAM 服务器机柜相邻的机柜看作第一个机柜)。画线时,应考虑侧门的厚度(BAM 服务器机柜和相邻的拼装机柜都安装侧门,BAM 服务器侧门为嵌入式,不用考虑厚度,拼装机柜侧门厚度为40mm )。

图Rack-4~图Rack-7给出了拼装机柜(包括直流配电柜)的支架孔位图。图Rack-4为支架安装孔位图; 图Rack-5为单个机柜安装孔位图;图Rack-6为两个机柜安装孔位图;图Rack-7为多个和多排机柜安装孔位图。 确定支架安装位置可以有两种方法:

(1) 参考图Rack-4~图Rack-7,根据施工平面设计图给定的基准尺寸,测量

出每排第一个支架(为端部支架)的支架位置及孔位,从第一个支架孔位出发,用墨斗划出两条平行于基准且间距为460mm 的直线,以第一个支架孔位为基准点,逐个划出其它支架的安装孔。为防止出现错误,在所有孔位线划好后应进行重复测量,核对尺寸的准确无误。

(2) 第二种方法是,参考图Rack-7,将所有的支架按照图中的位置摆放在地

板上,测量各支架的位置无误后,将各支架的位置以及所有的孔位作上标记。

划线和定位是机柜安装的基础,一定要注意准确性,否则会给以后的工作带来极大不便。

注意:

(1) 施工平面设计图中标注的尺寸一般是以机柜的边缘为基准。因此支架定位时,需要注意支架边缘与机柜边缘的差别。

(2) 如施工平面设计图要求一排拼装机柜的侧面与墙壁距离为800mm ,则端部支架的边缘应该与墙相距840mm 。因为安装侧门之前,机柜侧面边缘应该与支架边缘对齐,装上侧门(厚40mm )后,机柜边缘与支架边缘的距离为40mm ,与墙壁距离为800mm 。

(3) 同样机柜的正面(或背面)与墙壁的之间距离与支架端部与墙壁之间的距离也是有差别的。

BAM 服务器机柜采用B68服务器机柜,其机柜尺寸与拼装机柜不同(且机柜的宽度与侧门无关),因此支架的尺寸和孔位也与拼装机柜不同。安装时应特别注意!

B68服务器机柜的支架安装孔位图如图Rack-8所示。

图Rack-4 支架安装孔位图

图Rack-5 单个机柜安装孔位图

图Rack-6 两个机柜安装孔位图

图Rack-7 多个和多排机柜安装孔位图

图Rack-8 单个BAM 服务器机柜(B68服务器机柜)安装孔位图

2. 钻孔

在地面膨胀螺栓孔标记处,选择Ф14或Ф16的钻头打孔,孔深应保证膨胀螺栓的膨胀管刚好能全部放入孔内。

使用冲击钻(或电锤)打孔时要保证钻头与地面保持垂直,双手紧握钻柄,垂直向下用力,不要摇晃,以免破坏地面、加大孔径或使孔倾斜。

当钻头选择Ф14时,如果孔径小,则可以通过技术处理加大孔径。

如果地面特别坚固平滑,钻头不易定位,可先用样冲在孔位上凿一个凹坑,帮助钻头定位。

钻孔时,使用吸尘器,吸净灰尘,每天下班前要清除机房一切垃圾,做到“日清”。

划线和打孔是设备硬件安装的基础性工作,如果准确性不高会给以后工作带来极大不便,所以保证它们的质量是保证整个工程质量的必备条件。

2.2 固定支架

1. 安装膨胀螺栓

安装前,使用吸尘器将所有孔位内部、外部的灰尘清除干净,再对孔距测量,并放置支架看是否与孔位一一对应,对于误差较大的孔先不要安装膨胀螺栓,而要重新定位、打孔。

取下膨胀螺栓上的垫圈、螺母,将膨胀螺栓杆和膨胀管垂直放入孔中,用橡胶锤直接敲打膨胀螺栓,直到将膨胀螺栓的膨胀管全部敲入地面。

2. 调节支架高度

根据测量的地板高度值,参照支架上防静电地板高度的丝印标记,调节所有支架至预定高度,并用力矩扳手紧固高度锁定螺栓至45Nm 。此时螺栓紧固顺序应遵循“先中间,后两侧”的原则,即先分别紧固中间的两个高度锁定螺栓,再紧固两侧共四个高度锁定螺栓。见图Rack-9:

图Rack-9 支架与地面连接示意图

3. 支架的安装与固定

清洁地面和支架表面,按图Rack-9所示装入支架绝缘垫与支架绝缘套,将支架安装孔对正相应的膨胀螺栓,用螺母、垫圈将支架固定于地面,紧固力矩应达到45Nm 。

固定支架用的螺母应依次交叉紧固,以减小螺栓与支架间的应力,也便于在 安装过程中对支架进行校正,其它支架也按以上方法安装。

通过在支架底部加绝缘垫,膨胀螺栓处加绝缘套,使整套设备在未接地线之前,不与大地接通,能有效地满足绝缘要求。

2.3 支架绝缘测试

2.4 安装滑道调万用表至电阻档,用万用表的两个测量头分别与支架和拉爆膨胀螺栓接触,测量其间电阻。若电路呈现断路状态,继续下步安装。否则说明支架与地没有绝缘,此时检查是否漏装支架绝缘套或支架绝缘垫,或绝缘零件是 否损坏。重新进行支架的安装与固定,再进行绝缘测试。

拼装机柜的滑道每根长度为1600mm 。如果需要,现场将一根滑道锯断,成为两根长度为800mm 的滑道。

B68服务器机柜的滑道每根长度为1200mm ,同样可以现场锯断成为两根长度为600mm 的滑道。

滑道的安装过程如下:

1. 预装方形螺母

在安装滑道前,应将固定地板托组件及固定滑道用的方形螺母(两者相同) 预先装入滑道的下槽道,每台机柜下的每侧滑道中应装入五个方形螺母,其中中间三个留做固定地板托组件用,两侧的两个是滑道与支架固定时用。否则,滑道装好后,方形螺母就不能装入,滑道与支架的固定如图Rack-10所示。 每个机柜配有六套地板托组件,在机柜下两侧的滑道中各装入三套。

图Rack-10 滑道与支架固定及水平调节示意图

2. 调平、固定滑道

用方螺母、平垫、弹垫和M12×20螺栓将滑道固定于支架上,如图Rack-10所示。

首先旋上装有弹垫、平垫的M12×20螺栓(先不拧紧,螺栓不掉下即可),然后把螺栓依次卡入支架 孔内,然后用水平尺对滑道各段测量(横向与纵向同时测量),可通过增减垫片调节水平,如果水平则依次拧紧各螺栓,然后再进行水平测试,如图Rack-11所示。如果不水平,拧松螺栓,继续增减垫片,直到滑道水平。滑道安装完毕后,应达到以下几点要求:

(1) 单独的一根滑道纵向必须是水平的;

(2) 平行的两条滑道横向必须是水平的;

(3) 平行的两根滑道槽中心点测量值为460mm ±1mm ;

(4) 如有多条滑道对接安装时,用拉直的细线进行校正,必须保证多条滑道

在一条直线上。两条滑道衔接处应没有缝隙,没有高低不平现象。

图Rack-11 滑道水平测量示意图

3 安装地脚-压板组件

机柜在水泥地面的机房内安装时,采用地脚-压板组件将机柜固定在地面上。 安装地脚-压板组件的一般过程是:

(1) 安装地脚;

(2) 地脚-压板组件定位;

(3) 安装膨胀螺栓;

(4) 机柜就位;

(5) 安装压板;

(6) 地脚-压板绝缘测试。

3.1 安装机柜地脚

在将机柜摆放到设计位置之前,需要先完成机柜地脚的安装,具体安装方法见图Rack-12,安装时注意保证地脚的底平面和拼装机柜的底面的距离为55mm 。

置。

每个机柜使用4个地脚和压板。

图Rack-13为单个机柜安装孔和地脚位置图;图Rack-14为多个和多排机柜安装孔和地脚位置图。

划线的方法是:

参考图Rack-13和图Rack-14,根据施工平面设计图给定的基准尺寸, 测量出每排第一个机柜的地脚位置及压板的安装孔位。从第一个机柜的地脚位置出发,用墨斗划出两条平行于基准且间距为460mm 的直线,以第一个机柜的地脚位置为基准点,逐个划 出其它支架的安装孔。为防止出现错误,在所有位置及孔位线划好后应进行重复测量,核对尺寸的准确无误。

BAM 服务器机柜采用B68服务器机柜,其机柜尺寸与拼装机柜不同,因此地脚和压板地安装孔位的尺寸也与拼装机柜不同。安装时应特别注意!

BAM 服务器机柜和交换设备机柜同一排摆放且相邻时,画线时应特别考虑交换设备侧门的厚度。

BAM 服务器机柜的安装孔和地脚位置图如图Rack-15所示。

图Rack-13 单个机柜安装孔和地脚位置标记图

图Rack-14 多个和多排机柜安装孔和地脚位置标记图

⑴ 机柜边缘线 ⑵ 机柜地脚位置标记(4-φ50)

⑶ 使用M12膨胀螺栓 ⑷ 机柜门板边缘线 ⑸ 内墙或参考体

图Rack-15 B68服务器机柜地脚孔位布置图

2. 钻孔

在地面膨胀螺栓孔标记处,选择Ф14或Ф16的钻头打孔,孔深应保证膨胀螺栓的膨胀管刚好能全部放入孔内。

使用冲击钻(或电锤)打孔时要保证钻头与地面保持垂直,双手紧握钻柄, 垂直向下用力,不要摇晃,以免破坏地面、加大孔径或使孔倾斜。

当选择Ф14的钻头时,如果孔径稍小,可以通过技术处理加大孔径。

如果地面特别坚固平滑,钻头不易定位,可先用样冲在孔位上凿一个凹坑,帮助钻头定位。

钻孔时,使用吸尘器,吸净灰尘,每天下班前要清除机房一切垃圾,做到“日清”。

划线和打孔是设备硬件安装的基础性工作,如果准确性不高会给以后工作带来极大不便,所以保证它们的质量是保证整个工程质量的必备条件。

3.3 安装膨胀螺栓

取下膨胀螺栓上的垫圈、螺母,将膨胀螺栓杆和膨胀管垂直放入孔中,用橡 胶锤直接敲打膨胀螺栓,直到将膨胀螺栓的膨胀管全部敲入地面。

3.4 机柜就位和调整

在机柜就位之前,机柜地脚应已安装好。

(1) 抬起机柜就位,将机柜的四个地脚对正地面上四个相应的地脚位置标记,

如图Rack-16所示。

(2) 调整水平。

一排拼装机柜就位后,从左边第一个拼装机柜开始,旋转地脚的调平螺母调整拼装机柜与地面的距离,使同一排的拼装机柜高度相同,且保持水平。要求机柜的垂直度偏差不大于3mm ,从左至右依次调整每一个机柜。相同的方法再调整第二排、第三排机柜。

3.5 安装压板

机柜就位后,使用压板将装有地脚的机柜固定在地面上。

在地面的膨胀螺栓杆上自下而上依次穿上绝缘垫板、压板、支架绝缘套、垫 片,压板的开口处压在地脚上,用螺母拧紧,如图Rack-17所示。

(1)M16地脚 (2)螺母M16 (3)螺母M12 (4)弹垫12

(5)大平垫12 (6)支架绝缘套 (7)压板 (8)膨胀螺栓M12×80

(9)绝缘垫板 (10)膨胀管

图Rack-17 地脚-压板组件组成示意图

3.6 地脚-压板组件绝缘测试

调万用表至电阻档,用万用表的两个测量头分别与地脚和拉爆膨胀螺栓接触,测量其间电阻。若电路呈现断路状态,继续下步安装。否则说明地脚与地没有绝缘,此时检查是否漏装支架绝缘套或绝缘垫板,或绝缘零件是否损坏。并重新安装压板,然后再重新进行绝缘测试。

至此,地脚-压板组件和机柜就已经安装完成了,在进行下一步安装工作之前,应该注意将机房整理、清洁一遍,以保证下面安装工作的环境。

4 安装并柜过渡底框

如果拼装机柜与原有焊接机柜要并柜安装,且焊接机柜的支架伸出机柜(原焊接机柜的安装规范要求:考虑到扩容方便,一排机柜的最末端的支架应伸出机柜,即机柜未装侧门时,机柜边缘与最末端支架的中轴线对齐),就需要用并柜过渡底框进行过渡安装。(如果是新装一排机柜,或者拼装机柜与焊接机柜并柜安装,但焊接机柜的最后一个支架并不伸出机柜,则使用支架-滑道系统即可)。

并柜过渡底框的安装过程是:

(1) 划线、钻孔、安装膨胀螺丝;

(2) 安装支架。包括调节支架高度、安装支架、支架绝缘测试;

(3) 调平并固定并柜过渡底框。

其中需要注意的是划线和安装并柜过渡底框,其他各项安装过程与支架-滑道系统的安装完全一致。

下面主要说明划线和固定并柜过渡底框的方法:

1. 划线

以原有的机柜边缘为基准,按图Rack-18划线。

图Rack-18 并柜过渡底框安装孔位图

2. 固定并柜过渡底框

如图Rack-19所示,将并柜过渡底框放在原有支架和新安装的支架上,用M12×30 螺栓、弹垫、平圈将并柜过渡底框固定在支架上。

5 固定机柜

5.1 单个机柜的固定

单个机柜的固定方法,根据机柜安装方式的不同,分为三种情况:

(1) 使用支架-滑道系统安装(有防静电地板);

(2) 使用地脚-压板系统安装(无防静电地板);

(3) 使用并柜过渡底框安装(拼装机柜与焊接机柜并柜安装)。 读者和安装人员可根据实际情况选择阅读。

1. 采用支架-滑道系统时的机柜固定

使用M12×20螺栓、弹垫、平垫、方螺母将机柜的底脚与滑道固定,如图Rack-21所示。具体过程如下:

a) 逐个把拼装机柜抬上滑道,并将拼装机柜支架四个固定孔和滑道的

固定槽对齐,方螺母从滑道的槽道口装入并与拼装机柜、支架的固定孔对正,然后使用螺栓固定。

b) 一排拼装机柜就位后,先紧固最外面一台拼装机柜和滑道间的连接,

并调整好水平度(可以通过在机柜底脚和滑道之间加装垫片来调整水平),保证机柜的垂直度偏差不大于3mm 。 以第一台拼装机柜为基准,从左至右依次调整并紧固每一个拼装机柜。相同的方法再紧固第二排、第三排机柜。

先安装机柜的地脚,再用压板将装有地脚的机柜固定在地面上。 地脚-压板系统的安装方法前面已经介绍,这里不再赘述。 3. 采用并柜过渡底框时的机柜固定

采用并柜过渡底框时机柜的固定方法与采用支架-滑道系统时机柜的固定方法类似,但此时机柜不需要安装底脚,而是直接固定在过渡底框上。

将拼装机柜抬上并柜过渡底框,并将拼装机柜支架四个固定孔和底框的固定孔对齐,调整机柜水平后使用M12×20螺栓固定。

5.2 机柜间的连接固定

所有机柜就位并固定后,机柜应平齐并拢。为了使机柜更加牢固,单个机柜就位并固定后,要将相邻的机柜相互间连接固定,使一排机柜成为一个整体。 拼装机柜每个侧面的顶部和底部各有两个侧面连接孔。所有机柜调整水平后,相邻机柜的侧面连接孔是对齐的。

用螺栓穿过相邻拼装机柜的侧面连接孔(共4个,顶部2个,底部2个),再用平垫、弹垫和螺母将两个拼装机柜连接起来。

相邻拼装机柜的顶盖之间,顶盖与侧门之间应用M3×10的螺钉连接并紧固。 拼装机柜间的连接如图Rack-22所示。

在使用工具过程中要注意保护机柜,以免工具碰伤、划伤机柜。

Rack-23

6 安装机柜配件

1. 机柜的配件主要包括 (1) 走线槽;

(2) 机柜的上梁、下梁和顶盖;

(3) 机柜的前后门和侧门(包括侧门附件上拉板、中拉板和下拉板); (4) 机柜行列告警灯; (5) 防尘网;

(6) 地板托(有防静电地板时); (7) 机柜标签。

2. 在硬件安装过程中,可以根据实际情况选择上述配件的安装时机

(1) 机柜的上梁和顶盖以及机柜行列告警灯可以在固定机柜之前安装,也可

以在机柜固定以后安装; (2) 下梁一般在机柜固定以后安装;

(3) 机柜的前后门和侧门一般在机柜电缆安装完成后再安装(若在电缆安装

前就安装机柜门,可能会对电缆安装有影响); (4) 机柜的防尘网、地板托、机柜标签等一般在最后安装。

6.2 安装走线槽

走线槽有两种:

(1) 同一行交换设备机柜顶部的走线槽,用于承托电源线;

(2) 拼装机柜行与行之间的走线槽,用于机柜行与行之间HW 线、光纤的走

线。线槽两侧应紧贴机柜的上出线口。线槽的长度可调,两边线槽可以抽动,当两行机柜之间的距离为1150~1550mm时,都能满足要求。 1. 安装柜顶走线槽

交换设备机柜的顶部留有安装孔,用来安装走线槽,其结构尺寸如图Rack-23所示。

2. 安装行间走线槽

如果机柜采用双排摆放,则需要安装行间走线槽。行间走线槽一般安装在两排机柜的端部机柜的顶上。

行间的走线槽有开放式和封闭式两种。

开放式线槽使用托架固定。安装时使用M8×25的螺钉固定在机柜的顶部,如图图Rack-25所示。

图Rack-26 封闭式行间走线槽安装完成示意图

6.3 安装上下梁及顶盖

1. 安装上、下梁

每个拼装机柜(交换设备机柜和直流分配柜)的前后都有上下梁。其安装顺序如下:

(1) 将上梁安装于拼装机柜的上部,前后各一个; (2) 将下梁安装于拼装机柜的底部,前后各一个。 上下梁及顶盖的安装参见图Rack-27:

图Rack-27 上梁和下梁的安装示意图

说明:

B68服务器机柜的上梁与顶盖连为一体,其安装方法与拼装机柜类似。

2. 安装顶盖

机柜顶部有前顶盖和后顶盖,既美观又可起到防止异物掉入的作用。顶盖安装过程如下:

(1) 将前后顶盖固定在机柜的上梁上,如图Rack-28所示; (2) 将一行机柜中相邻机柜的前后顶盖用螺钉相互连接起来; (3) 每行机柜侧面的两个机柜上的顶盖要与侧门用螺钉连接。

6.4 安装门机柜门分为前后门和侧门。

每个机柜的前后各有左右两扇对开的柜门,使用插销安装在机柜上; 在一排机柜的两侧需要安装侧门。拼装机柜的侧门使用侧门附件上拉板、中拉板和下拉板固定在机柜上;B68服务器机柜的侧门直接固定在机柜上。 1. 安装上拉板、中拉板和下拉板

拼装机柜的侧门使用上拉板、中拉板和下拉板固定在机柜上,安装侧门首先要安装上拉板、中拉板和下拉板。

B68服务器机柜的侧门安装不需要此步骤。

这三套附件的安装顺序如下,参看图Rack-29。 (1) 将上拉板安装于拼装机柜侧面的上部; (2) 将中拉板安装于拼装机柜侧面的中部; (3) 将下拉板安装于拼装机柜侧面的下部。

Rack-31

2. 安装侧门 (1) 拼装机柜

安装侧门时先注意下固定边与机柜下围框对齐,更容易装配。固定好上下共6个螺钉即可,侧门安装如图Rack-31所示:

3. 安装前后门

每个机柜前后各有左右两扇门,左右门的安装方法相同,左门安装方法如下: (1) 将门的右下端孔与拼装机柜上的销对准,将左门下端装上。

(2) 用手拉下左门上端的三角形钩销,将门上的孔与拼装机柜上的孔对齐,

松开手,在弹簧力作用下钩销往上复位将门安装在拼装机柜上。 (3) 用接地线将机柜门和机柜可靠连接。

B68服务器机柜的左右门的尺寸与普通拼装机柜不同,但是其安装方法相同。 前后门的安装示意图见图Rack-32。

说明:

6.5 安装行列告警灯

机柜行列告警灯位于机柜的顶盖上或侧门上部。通过行列告警灯, 可以迅速发现产生告警的机柜。

行列告警灯分为行灯和列灯,包括红、黄、绿三个告警灯,分别用于指示一级告警、二三级告警和四级告警。

行灯安装在一行机柜两端的侧门上部,用于向维护人员指示是哪一行机柜的设备发生了告警;

列灯安装在每个机柜的前顶盖上,向维护人员指示是哪一个机柜的设备发生了告警。

行列告警灯的安装位置如图Rack-33所示

机柜顶盖

红黄绿灯灯灯

红黄绿

机柜顶盖

列告警

C&C08

灯灯灯

C&C08

红黄绿灯灯灯

行告警灯

侧门

图Rack-33 行、列告警灯示意图

行列告警灯的安装过程如下:

(1) 将告警灯按照图Rack-33的位置顺序安装到机柜的前顶盖和侧门上。 (2) 连接行列灯控制线

每个交换机柜都配有一块CB01AMD 板,用于处理风扇告警和驱动行列告警灯,该板发货时已安装在机柜顶部配电盒中。现场需要用行列灯控制线连接CB01AMD 板和行列告警灯。

行列灯控制线一端为一个4PIN 插头,接AMD 板;另一端为六个端子,包括红、黄、绿三个端子和三个黑色端子,一个黑色端子与一个彩色端子为一组,连接相应颜色的告警灯。

安装时,4PIN 插头插到AMD 板上的J6(行灯)或J7(列灯);将对应颜色的端子安装到行列灯的一个电源端子上,黑色端子连接到行列灯的另一个电源端子上。 (3) 安装行灯级连线

行灯级连线的两端均为4PIN 插头。互连两个机柜时,一端接在左边机柜AMD 板的J5上,另一端接在右边机柜的J4上。

6.6 安装防尘网

机柜的风扇箱安装在机柜内的底部,风扇单元安装在机柜内的顶部,风从机柜底部通风孔进入,为防止灰尘或其他小的异物被风带入机柜,在风扇箱内的底部安装有防尘网,每个风扇箱里并列有两块。防尘网可定期取出清洗或更换。

防尘网的安装过程如下:

(1) 拧松风扇箱下部的防尘网箱面板上的紧固螺丝,抽出防尘网箱; (2) 并排插入两块防尘网;

(3) 将防尘网箱推入机柜,拧紧面板上的紧固螺丝。 防尘网的安装如图Rack-34、图Rack-35所示。

注意:

(1) 交换设备机柜、B68服务器机柜的底部都要安装防尘网。B68机柜的侧门也安装有防尘网。

(2) 由于运输的颠簸,每一台机柜在机房安装好后,要抽出风扇箱内下部的防尘网,看两块防尘网是否有挪位、重叠现象,如果有的话,一定要将其复原,保证防尘效果。

6.7 安装过线孔盖板

在拼装机柜的顶部和底部有光纤和中继线等过线孔,光纤和中继线等从过线孔过线后,为了防止老鼠、灰尘或杂物进入机柜,过线孔除了光纤或电缆外的间隙要用长盖板或短盖板盖上,如图Rack-36所示。

在有些情况下,电源线要从底部引入,在拼装机柜两侧的顶部和底部各有6个电源线过线孔,供电源线从机柜底部进入。拼装机柜侧面过线孔结构示意图见图Rack-37。

注意:

B68服务器机柜的顶部和底部都有过线孔。过线孔用的是塑料盖板。线缆要从过线孔穿过时,用小刀在塑料盖板上划出所需的孔即可。

用它来支撑机柜周边的防静电地板。安装盖板的目的一 是在支架和防静电地板之间起绝缘作用,二是遮挡机柜底部的缝隙。

安装地板托和盖板、复原地板等工作一般在硬件安装的最后进行。 1. 固定地板托

根据需要确定地板托的位置,先用M12×20螺栓、平垫、弹垫将固定弯板固 定在滑道上(滑道内已经预装了方螺母,见本章“2.4 安装滑道”)。 2. 安装盖板和活动弯板

用M8×30螺栓、平垫、弹垫、绝缘垫将盖板、活动弯板固定在固定弯板上,地板托的固定及安装盖板和活动弯板如图Rack-38所示。

图Rack-38 地板托安装图

3. 确定活动弯板位置

拧松图Rack-38所示地板托组件中的M8×30螺栓,上下移动活动弯板,使活动弯板的上平面与防静电地板的下平面等高,拧紧螺栓。

4. 地板托绝缘测试

调万用表至电阻档,用万用表的两个测量头分别与支架和地板托组件中的活 动弯板接触,测量其间电阻。若电路呈现断路状态,继续下步安装。否则说 明支架与地板没有绝缘,此时拆开地板托组件检查其中是否漏装绝缘板和绝缘垫,或绝缘板、绝缘垫被损坏。重复前面第2、3步,然后重新进行地板托绝缘测试。

5. 复原地板

根据现场实际情况,切割机柜周边的防静电地板,并复原地板。

6.9 贴装机柜标签

1. 机柜标签的外形及含义

机柜标签可表示机柜的物理位置,可分为行标签和列标签。行标签为圆形,标号为大写字母;列标签为方形,标号为数字。机柜标签如图Rack-39所示:

图Rack-39 机柜标签示意图

2. 机柜的编号

机柜标签可表示机柜的物理位置,给维护人员提供准确的设备位置标志信息。维护人员根据这些标志可以很快找到自己所关心的设备,机柜上标签的具体编号是和配置数据中的位置描述值一一对应的。

通常情况下当机柜为一行布置时,靠近主走道的第一台机柜列号标签为“00”,贴在机柜上围框上;第二台机柜列号标签为“01”,第三台机柜列号标签为“02”,以此类推第十二台列号标签为“11”;机柜两端的侧板上贴上行号标签为“(A)”。

当机柜为多行布置时,管理/通讯模块机柜通常排在靠近控制室的第一行,机柜两端的侧板上贴上行号标签“(A)”;第二行行号标签为“(B)”;第三行行号标签为“(C)”。

3. 标签贴装在机柜上的位置

行列标签的贴装位置在机柜上有相应的标记:

(1) 行号的安装位置

行号标签为圆形,安装在侧门上。

(2) 架号的安装位置

架号标签为长方形,安装在拼装机柜的上横梁上。

至此,整个机柜安装完毕。

7 机柜安装检查

机柜安装完毕后,应注意检查以确保安装正确。检查时要注意以下事项:

(1) 机柜连接后,要求做到稳立不动,整齐美观。

(2) 机柜的垂直偏差度应不大于3mm 。

(3) 四面走道侧的机柜面板应全部装上,并对齐成直线,误差不大于5mm 。

相邻拼装机柜应紧密靠拢,高度一致,整列机面应在同一平面上,无凹凸现象。

(4) 各种螺钉要全部拧紧,但不可扭伤螺纹和螺帽。

(5) 拼装机柜上的各零件不得脱落或碰坏,连线不能碰伤、碰断。各种标志

牌应正确、清晰、齐全。

(6) 要清洁机柜,使安装过程中手触摸的痕迹不被看见。

(7) 使用工具时要注意保护机柜,不使机柜表面受损。

(8) 机柜安装完毕后,用卷尺测量每台机柜与参照物上、中、下端的尺寸,

尺寸应一致,机柜两排之间的两端及中间测量尺寸也应相同。


相关内容

  • 智能化建筑工程竣工验收资料文档
  • 文 件 目 录 人武部综合信息化工程建设 交 工 技 术 文 件 建设项目名称:河津市人武部国防动员指挥中心综合信息化 工程 单项工程名称 :办公楼弱电布线.全自动化办公设备.安 防监控系统.UPS 电源系统.防静电系统.高配置电脑+网络安全系统.单色LET 显示屏.DLP 高清无缝拼接大屏幕投影等 ...

  • 机房布线规范
  • 机房布线规范 目 录 机房布线规范 (版本1.0) 目 录 第一章 总则 第二章 机房环境要求 第三章 机架基本要求 第四章 设备机架安装及摆放标准 第一节 设备安装前要求 第二节 机架加固与防震 第三节 设备机架安装 第四节 外围终端设备 第五节 电缆走线架(走线槽道) 第五章 机房线缆要求 第一 ...

  • 密封条选用手册
  • 文件编号:XJJG/JS 012-2007 V01 机柜附件选用手册 常用密封条 文件编号:XJJG/JS010-2007 V01 前 言 <机柜附件选用手册>分为以下分册: 第一分册 <标准件及非标紧固件手册> 第二分册 <机柜锁选用手册> 第三分册 <常 ...

  • 基于钢丝绳隔振器的陆用车载雷达机柜隔振设计
  • 电子机械工程 18 Electro -M echan i ca l Eng i n eer i n g 2005年第21卷第6期2005. Vol . 21No . 6 基于钢丝绳隔振器的陆用车载雷达机柜隔振设计 曹 斌 (中国电子科技集团公司第二十研究所, 陕西西安710068) 3 摘 要:以陆 ...

  • 移动测量车的介绍
  • --车载移动测量系统解说词 外观 车载移动测量系统是由一辆江淮车和数据采集设备构成.(现场展示) 硬件设备 现在展示在我们眼前的是四川测绘地理信息局第三测绘工程院于2012年引进前的车载移动测量系统,从外面观看车载移动测量系统,我们可以看到四大数据采集器.在江淮车顶的左前方为3个CCD 相机.右前方 ...

  • 中心控制室及操作站搬迁的设计探讨
  • 第50卷第4期 2014年8月 石油化工自动化 AUT()MATIONINPETR()_CHEMICAI.INDUSTRY V01.50,No.4Aug,2014 中心控制室及操作站搬迁的设计探讨 陈彦旭 (茂名瑞派石化工程有限公司,广东茂名525011) 摘要:石油化工企业在向着大型化.一体化.智 ...

  • 第五师医院机房建设的必要性及初步建议1
  • 第五师医院网络机房建设的必要性及初步建议 机房现状:医院目前的机房是以前门诊楼整个综合布线的一个设备间,本不具备机房的基本需求,面积大约10个平米,包括门诊楼布线设备,电池房是一个诊室格出来的一个小格间,上部连通诊室.机房有一个综合布线的机柜,一个放服务器.存储.核心交换.防火墙等设备的机柜,影像放 ...

  • 高低压电气安全操作规程
  • 高低压电气安全操作规程 高低压开关的操作必须按程序操作,否则将会对人身设备造成损伤和损坏,直至生命安全.故根据我公司高低压系统的具体结构,特制定如下安全操作规程: 一.概述 我公司高低压配电室计有:1.原料磨电气室高压#1进线柜系统,#1进线柜(园泥#1线路)编号:41EAH01(3-2010-Q- ...

  • 19英寸标准机箱尺寸标准
  • 19英寸标准机箱尺寸标准 1 19英寸标准机柜尺寸: 19寸标准机柜内设备安装所占高度用一个特殊单位"U" 表示,1U=44.45mm.u 是指机柜的内部有效使用空间,使用19寸标准机柜的标准设备的面板一般都是按n 个U 的规格制造. 对于一些非标准设备,大多可以通过附加适配档板 ...