安全检测与监控技术课程设计

水塔水位检测控制系统的设计

摘要:本文采用PLC进行主控制,在水箱上安装一个自动测水位装置。利用水的导电性连续地全天候地测量水位的变化,把测量到的水位变化转换成相应的电信号,主控台对接收到的信号进行数据处理,完成相应的水位显示、故障报警信息显示、实时曲线和历史曲线的显示,使水位保持在适当的位置。 关键词:可编程逻辑控制器(PLC)自动控制系统水塔水位

Abstract

In the modern time, the Full-automatic washer is entering every family. The article introduces a new decelerating clutch, which is used in fully-auto washing machine, it can improve the current technology, simplify structure, it is also helpful to reduce cost and increases reliability.The thesis simply discusses the application research on water tower water level auto control system. It analyzes the limitation on the pre-designation of water tower water level auto control system, and devises the advanced plan. To be proved in the practice, the water tower water level auto control system is compatible for all kinds of liquids, and can throw into the effective production.

Keywords: programmable logic controllers (PLC) Auto Control System, Water Level Water Tower

摘要: ............................................................................................................................................................... - 1 - 关键词: ........................................................................................................................................................... - 1 - Abstract ........................................................................................................................................................... - 1 -

前言 ....................................................................................................................................................................... 2

第 1 章水塔水位控制系统方案设计 ................................................................................................................. 3

1.1 方案设计原则 ....................................................................................................................................... 3

1.2 系统的整体设计要求 ........................................................................................................................... 3

1.3 控制系统的设计 ................................................................................................................................... 4

1.3.1继电器控制系统 ........................................................................................................................ 4

1.3.2单片机控制 ................................................................................................................................ 4

1.3.3工业控制计算机控制 ................................................................................................................ 4

1.3.4可编程序控制器控制 ................................................................................................................ 4

第 2 章水塔水位控制系统的硬件设计 ............................................................................................................. 6

2.1 PLC的基本结构 .................................................................................................................................... 6

2.2 PLC 机型选择 ....................................................................................................................................... 8

2.3PLC容量选择 .......................................................................................................................................... 9

2.4 I/O 模块的选择 ................................................................................................................................. 10

2.5 电源模块的选择 .................................................................................................................................. 11

2.6水塔水位的工作流程: ...................................................................................................................... 12

第3章水塔水位控制系统软件设计 ................................................................................................................. 13

3.1PLC输入 /输出信号及地址分配 ........................................................................................................ 14

3.2主电路的设计 .................................................................................................................................. - 16 -

3.3水塔水位控制系统的PLC控制流程图 .......................................................................................... - 16 -

3.6系统调试 .......................................................................................................................................... - 17 - 总结 ................................................................................................................................................................. - 19 -

参考文献 ............................................................................................................................................................. 20

前言

可编程控制器(PLC)是以计算机技术为核心的通用自动化控制装置,它的功能性强,可靠性高,编程简单,使用方便,体积小巧,近年来在工业生产中得到广泛的应用,被誉为当代工业自动化主要支柱之一。现今社会,自动化装置无所不在,在控制技术需求的推动下,控制理论本身也取得了显著的进步。水塔水位的监测和控制,再也不需要人工进行操作。实践证明,自动化操作,具有不可替代的应用价值。水塔水位自动控制器,具有适应各种液体液位的检测和控制的功能,设计中分析了利弊,考虑了各种液体的阻值大小,是可以投入实际生产的产品。

第 1 章水塔水位控制系统方案设计

1.1 方案设计原则

整个设计过程是按工艺流程设计,为设备安装、运行和保护检修服务,设计的编写按照国家关于电气自动化工程设计中的电气设备常用基本图形符号(GB4728)及其他相关标准和规范编写。设计原则主要包括:工作条件:工程对电气控制线路提供的具体资料,系统在保证安全、可靠、稳定、快速的前提下,尽量做到经济、合理、合用,减小设备成本。在方案的选择、元器件的选型时更多的考虑新技术、新产品。控制由人工控制到自动控制,由模拟控制到微机控制,使功能的实现由一到多而且更加趋于完善。

对于本课题来说,液体混合系统部分是一个较大规模工业控制系统的改适升级,控制装置需要根据企业设备和工艺现况来构成并需尽可能的利用旧系统中的元器件。对于人机交互方式改造后系统的操作模式应尽量和改造前的相类似,以便于操作人员迅速掌握。从企业的改造要求可以看出在新控制系统中既需要处理模拟量也需要处理大量的开关量。系统的可靠性要高。人机交互界面友好,应具备数据储存和分析汇总的能力。

要实现整个液体混合控制系统的设计,需要从怎样实现多个电磁阀的开关以

及电动机启动的控制这个角度去考虑,现在就这个问题的如何实现以及选择怎样 的方法来确定系统方案。

1.2 系统的整体设计要求

在水塔水位控制过程中,整体控制要求如下:

当水池液体位于下限液位开关S1,S1此时为ON,电磁阀打开,开始往水池里注水,当4S以后,若水池液位没有超过水池下限液位开关时,则系统发出报警,若系统正常,此时水池下限位开关S4为OFF,表示水位高于下限水位。当水位液面高于上限水位,则S2为ON,电磁阀关闭。当水塔水位低于水塔下限水位时,则水塔下限水位开关S3为ON,水泵开始工作,向水塔供水,当S3为OFF

时,则水塔上限水位S4为OFF,水泵停止。当水塔水位低于下限水位,同时水池水位也低于下限水位时,水泵不能启动。

1.3 控制系统的设计

1.3.1继电器控制系统

控制功能是用硬件继电器实现的。继电器串接在控制电路中根据主电路中的电压、电流、转速、时间及温度等参量变化而动作,以实现电力拖动装置的自动控制及保护。系统复杂,在控制过程中,如果某个继电器损坏,都会影响整个系统的正常运行,查找和排除故障往往非常困难,虽然继电器本身价格不太贵,但是控制柜的安装接线工作量大,因此整个控制柜价格非常高,灵活性差,响应速度慢。

1.3.2单片机控制

单片机作为一个超大规模的集成电路,机构上包括 CPU、存储器、定时器和多种输入/输出接口电路。其低功耗、低电压和很强的控制功能,成为功控领域、尖端武器、日常生活中最广泛的计算机之一。但是,单片机是一片集成电路,不能直接将它与外部 I/O信号相连。要将它用于工业控制还要附加一些配套的集成电路和 I/O接口电路,硬件设计、制作和程序设计的工作量相当大。

1.3.3工业控制计算机控制

工控机采用总线结构,各厂家产品兼容性强,有实时操作系统的支持,在要求快速、实用性强、功能复杂的领域中占优势。但工控机价格较高,将它用于开关量控制有些大材小用。且其外部I/O接线一般都用于多芯扁平电缆和插头、插座,直接从印刷电路板上引出,不如接线端子可靠。

1.3.4可编程序控制器控制

可编程控制器配备各种硬件装置供用户选择,用户不用自己设计和制作硬件装置,只须确定可编程序控制器的硬件配制和设计外部接线图,同时采用梯形图语言编

程,用软件取代继电器电器系统中的触点和接线,通过修改程序适应工艺条件的变化。

可编程控制器(PLC)从上个世纪 70 年代发展起来的一种新型工业控制系统,起初它主要是针对开关量进行逻辑控制的一种装置,可以取代中间继电器、时间继电器等构成开关量控制系统。随着30 多年来微电子技术的不断发展,PLC也通过不断的升级换代大大增强了其功能。现在 PLC 已经发展成为不但具有逻辑控制功能、还具有过程控制功能、运动控制功能和数据处理功能、连网通讯功能等多种性能,是名符其实的多功能控制器。由PLC为主构成的控制系统具有可靠性高、控制功能强大、性价比高等优点,是目前工业自动化的首选控制装置。故选择PLC来实施本次设计。

1.开关量的逻辑控制

这是 PLC 最基本、最广泛的应用领域,它取代传统的继电器电路,实现逻辑控制、顺序控制,既可用于单台设备的控制,也可用于多机群控及自动化流水线。如注塑机、印刷机、订书机械、组合机床、磨床、包装生产线、电镀流水线等。

2.运动控制

PLC 可以用于圆周运动或直线运动的控制,世界上各主要 PLC 厂家的产品几乎都有运动控制功能,广泛用于各种机械、机床、机器人、电梯等场合。

3.闭环过程控制

过程控制是指对温度、压力、流量等模拟量的闭环控制。作为工业控制计算机,PLC 能编制各种各样的控制算法程序,完成闭环控制。PID 调节是一般闭环控制系统中用得较多的调节方法。过程控制在冶金、化工、热处理、锅炉控制等场合有非常广泛的应用。

4.数据处理

现代 PLC 具有数学运算(含矩阵运算、函数运算、逻辑运算)、数据传送、数据转换、排序、查表、位操作等功能,可以完成数据的采集、分析及处理。数据处理一般用于大型控制系统,如无人控制的柔性制造系统;也可用于过程控制系统,如造纸、冶金、食品工业中的一些大型控制系统。

5.通信及联网

PLC通信含 PLC间的通信及 PLC与其它智能设备间的通信。随着计算机控

制的发展,工厂自动化网络发展得很快,各PLC厂商都十分重视 PLC的通信功能,纷纷推出各自的网络系统。新近生产的PLC 都具有通信接口,通信非常方便。根据本控制系统的控制要求应该选择可编程序控制器控制。

第 2 章水塔水位控制系统的硬件设计

2.1 PLC的基本结构

PLC是以微处理器为核心的计算机控制系统。如图2.1.2所示

图2.1.2

1、中央处理单元(CPU)

PLC的中央处理器与一般的计算机系统一样,是PLC的控制中枢,其性能决定了PLC的性能。它按PLC中程序赋予的功能有条不紊地进行工作。

2、存储器(RM/ROM)

存储器是具有记忆功能的半导体电路,主要用来存放系统程序、用户程序和工作数据等。PLC中使用的存储器由只读存储器(ROM)、只读存储器(ROM)及可擦除只读存储器(EPROM)组成。存储器是衡量PLC性能的一个重要指标。

3、I/O接口

输入接口一般由数据输入寄存器、选通电路和中断请求逻辑电路构成,负责微处理器及外部设备交换信息。它接受来自现场检测不见(如限位开关、操作按钮、选择开关、行程开关)以及其他一些传感器输出的开关量或模拟量(要通过模数变换进入机内)等各种状态控制信号,并存入输入映像寄存器。

输入接口采用光电耦合电路将PLC与现场设备隔离起来,以提高PLC的抗干扰能力。输入接口电路通常有两类:一类为直流输入型,另一类是交流输入型。

输出接口模块是PLC与现场设备之间的连接部件,用来将输出信号送给控制对象。其作用是将中央处理单元送出的弱电控制信号转换成现场需要的强电信号并输出,以驱动电磁阀、接触器、电动机等被控设备的执行元件。

4、I/O扩展接口

小型的PLC输入输出接口都是与中央处理单元CPU制造在一起的。为了满足被控设备输入输出点数较多的要求,常需要扩展数字量输入输出模块;为了满足模拟量控制的需要,常需要扩展模拟量输入输出模块,如A/D、D/A转换模块等。I/O扩展接口就是为连接各种扩展模块而设计的。

5、通讯接口

通讯接口用于PLC与编程器、计算机、变频器、触摸屏以及其他PLC等智能设备之间的连接,以实现PLC与智能设备之间的数据传送。

6、编程器

编程器主要有两种。一种是PLC专用编程器,有手持式和台式等。另一种是基于个人计算机系统的PLC编程器。

7、电源

电源部件将交流电源转换成供PLC内部需要的直流电源。它的好坏直接影响PLC的功能和可靠性,因此目前大部分PLC均采用开关式稳压电源供电,同时还向各种扩展模块提供24V直流电源。

2.2 PLC 机型选择

机型选择的基本原则是在满足控制功能要求的前提下,保证系统工作可靠、维护使用方便及最佳的性能价格比。具体应考虑的因素如下所述。

1.结构合理

对于工艺过程比较固定、环境条件较好、维修量较小的场合,选用整体式结构的 PLC;否则,选用模块式结构的 PLC,物料混合控制系统的设计选用整体式结构的 PLC 能够达到要求。

2.功能强、弱适当

对于开关量控制的工程项目,若控制速度要求不高,一般选用低档的 PLC,西门子公司的 S7-200 系列机或欧姆龙公司的 COM1。

3.机型统一

PLC 的结构分为整体式和模块式两种。整体式结构把 PLC 的 I/O 和 CPU 放在一块印刷电路板上,并封装在一个壳体内,省去了插接环节,因此体积小、价格便宜。但由于整体式结构的 PLC 功能有限,只适用于控制要求比较简单的系统。一般大型的控制系统都使用模块式结构,这样功能易扩展,比整体式灵活。一个大型企业选用 PLC 时,尽量要做到机型统一。由于同一机型的 PLC,其模块可互为备用,以便备件的采购和管理;另外,功能及编程方法统一,有利于技术人员的培训;其外部设备通用也有利于资源共享。若配备了上位计算机,可把各独立系统的多台 PLC 联成一个多级分布式控制相互通信,集中协调管理。物料混合控制系统控制要求比较简单选择整体式结构的 PLC。

4.是否在线编程

PLC 的特点之一是使用灵活。当被控设备的工艺过程改变时,只需用编程器重新修改程序,就能满足新的控制要求,给生产带来很大方便。PLC 的编程分为离线编程和在线编程两种。离线编程的 PLC,其主机和编程器共用物料混合控制系统采用离线编程。

5.PLC 的环境适应性

由于 PLC 是直接用于工业控制的工业控制器,生产厂家都把它设计成能在恶劣

的环境条件下可靠地工作。尽管如此,每种 PLC 都有自己的环境技术条件,用户在选用时,特别是在设计控制系统时,对环境条件要进行充分的考虑。一般 PLC及其外部电路(I/O 模块、辅助电源等)都能在下列环境条件下可靠工作: 温度:工作温度 0~55℃,最高为 60℃

储存温度: -40℃~+85℃

湿度:相对湿度 5%~95%(无凝结霜)

振动和冲击:满足国际电工委员会标准

电源:交流 220V,允许变化范围为-15%~+15%,频率为 47~53Hz

瞬间停电保持 l0ms

环境:周围空气不能混有可燃性、爆炸性和腐蚀性气体

对于需要应用在特殊环境下的 PLC,要根据具体的情况进行合理的选择。

2.3PLC 容量选择

PLC 容量包括两个方面:一是 I/O 的点数;二是用户存储器的容量(字数)。PLC容量的选择除满足控制要求外,还应留有适当的裕量,以做备用。根据经验, 在选择存储容量时,一般按实际需要的10%~25%考虑裕量。对于开关量控制系统,存储器字数为开关量 I/O乘以 8;对于有模拟量控制功能的 PLC,所需存储器字数为模拟内存单元数乘以100。通常,一条逻辑指令占用存储器一个字。计时、计数、移位及算术运算、数据传输等指令占用存储器两个字。各种指令占存储器的字数可查阅PLC产品使用手册。 I/O点数也应留有适当裕量。由于目前I/O点数较多的 PLC价格也较高,若备用的 I/O点的数量太多,将使成本增加。根据被控对象的输入信号和输出信号的总点数,并考虑到今后的调整和扩充,通常I/O点数按实际需要的10%~15%考虑备用量。

2.4 I/O 模块的选择

PLC 是一种工业控制系统,它的控制对象是工业生产设备或工业生产过程,

它的工作环境是工业生产现场。它与工业生产过程的联系是通过I/O接口模块可

以检测被控生产过程的各种参数,并以这些现场数据作为控制器对被控制对象进

行控制的依据。同时控制器又通过 I/O接口模块将控制器的处理结果送给工业

生产过程中的被控设备,驱动各种执行机构来实现控制。外部设备或生产过程中

的信号电平各种各样,各种机构所需的信息电平也是各种各样的,而PLC的 CPU

所处理的信息只能是标准电平,所以 I/O接口模块还需实现这种转换。PLC 从

现场收集的信息及输出给外部设备的控制信号都需经过一定距离。为了确保这些

信息的正确无误,PLC 的 I/O 接口模块都具有较好的抗干扰能力。根据实际需

要,PLC 相应有许多种 I/O接口模块,包括开关量输入模块、开关量输出模块、

模拟量输入模块及模拟量输出模块,可以根据实际需要进行选择使用。

1确定 I/O点数

I/O点数的确定要充分的考虑到裕量,能方便地对功能进行扩展。对一个控

制对象,由于采用不同的控制方法或编程水平不一样,I/O点数就可能有所不同。

2.开关量 I/O

标准的 I/O接口用于同传感器和开关(如按钮、限位开关等)及控制(开/关)

设备(如指示灯、报警器、电动机起动器等)进行数据传输。典型的交流I/O

信号为 24~240V(AC),直流I/O信号为 5~24V(DC)。

3.选择开关量输入模块主要从下面两方面考虑:一是根据现场输入信号与PLC

输入模块距离的远近来选择电平的高低。一般 24V 以下属于低电平,其传输距

离不宜太远。如 12V 电压模块一般不超过10m,距离较远的设备选用较高电压

模块比较可靠。二是高密度的输入模块,如32 点输入模块,能允许同时接通的

点数取决于输入电压和环境温度。一般同时接通的点数不得超过总输入点数的

60%。

4.选择开关量输出模块时应从以下三个方面来考虑:一是输出方式选择。输出

模块有三种输出方式:继电器输出、晶闸管输出、晶体管输出。其中,继电器输

出价格便宜,使用电压范围广,导通压降小,承受瞬时过电压和过电流的能力强,

且有隔离作用。但继电器有触点,寿命较短,且响应速度较慢,适用于动作不频

繁的交/直流负载。当驱动电感性负载时,最大开闭频率不得超过 1Hz。晶闸管

输出(交流)和晶体管输出(直流)都属于无触点开关输出,适用于通断频繁的

感性负载。感性负载在断开瞬间会产生较高反电压,必须采取抑制措施。二是输

出电流的选择。模块的输出电流必须大于负载电流的额定值,如果负载电流较大,

输出模块不能直接驱动时,应增加中间放大环节。对于电容性负载、热敏电阻负

载,考虑到接通时有冲击电流,要留有足够的余量。三是允许同时接通的输出点

数。在选用输出点数时,不但要核算一个输出点的驱动能力,还要核算整个输出

模块的满负荷负载能力,即输出模块同时接通点数的总电流值不得超过模块规定

的最大允许电流值。

2.5 电源模块的选择

电源模块的选择一般只需考虑输出电流。电源模块的额定输出电流必须大于处理

器模块、I/O模块、专用模块等消耗电流的总和。以下步骤为选择电源的一规则:

1.确定电源的输入电压;

2.将框架中每块 I/O 模块所需的总背板电流相加,计算出 I/O 模块所需的总

背板电流值;

3.I/O模块所需的总背板电流值再加上以下各电流:

1)框架中带有处理器时,则加上处理器的最大电流值;

2)当框架中带有远程适配器模块或扩展本地I/O适配器模块时,应加上其最

大电流值。

4.如果框架中留有空槽用于将来扩展时,可做以下处理;

1)列出将来要扩展的 I/O模块所需的背板电流;

2)将所有扩展的 I/O模块的总背板电流值与步骤。

5.在框架中是否有用于电源的空槽,否则将电源装到框架的外面。

6.根据确定好的输入电压要求和所需的总背板电流值,从用户手册中选择合适

的电源模块。具体应考随着 PLC 技术的发展,PLC 产品的种类越来越多,而且

功能也日益完善。PLC 的种类繁多,其结构、性能、容量、指令系统、编程方式、

价格等各有不同,当然使用场合也有所不同。因此选择合理的PLC对提高 PLC

控制系统技术经济指标意义重大。因此在选择机型时不仅要满足其功能要求及维

护等方面的虑:

1)合理的结构形式

2)安装方式的选择

3)相当的功能要求

4)系统可靠性的要求

综上所述,根据控制系统要求选择 S7-200 系列 PLC,S7-200 系列 PLC属于小

型整体式结构的 PLC,本机自带 RS485 通信接口,内置电源和 I/O 接口,

它的结构小巧,运行速度快,可靠性高,具有极其丰富的指令系统和扩展模块,

实时性和通信能力强大,便于操作,易于掌握,性价比高,是中小规模控制系统

的理想控制设备。

2.6水塔水位的工作流程:

当水池液体位于下限液位开关S1,S1此时为ON,电磁阀打开,开始往水池里

注水,当4S以后,若水池液位没有超过水池下限液位开关时,则系统发出报警,

若系统正常,此时水池下限位开关S4为OFF,表示水位高于下限水位。当水位

液面高于上限水位,则S2为ON,电磁阀关闭。当水塔水位低于水塔下限水位

时,则水塔下限水位开关S3为ON,水泵开始工作,向水塔供水,当S3为OFF

时,则水塔上限水位S4为OFF,水泵停止。当水塔水位低于下限水位,同时水

池水位也低于下限水位时,

水泵不能启动。如图2.1.

第3章水塔水位控制系统软件设计

3.1PLC输入 /输出信号及地址分配

根据上述水塔水位控制要求的分析,PLC的输入信号有蓄水池水位上下限液

位传感器信号,水塔水箱水位上下限液位传感器信号。PLC的输出信号有进水口

阀门控制电磁阀、水泵电机控制接触器、蓄水池和水塔水箱水位故障报警信号灯。

由上述PLC输入 /输出信号分析可知,选择S7-200系列的PLC即可满足控制要

求,其输入 /输出地址分配如表1所示。

表1 I/O分配图

1

3.2主电路的设计

3.3水塔水位控制系统的PLC控制流程图

根据设计要求,控制流程图如图所示

3.6系统调试

保持水池的水位在S3——S4之间,当水池水位低于下限液位开关S3,此时S3为ON,电磁阀打开,开始往水池里注水,当5S以后,若水池水位没有超过水池下限液位开关S3时,则系统发出警报;若系统正常运行,此时水池下限液位开关S3为OFF,表示水位高

于下限水位。当页面高于上限水位S4时,则S4为ON,电磁阀关闭。

2)保持水塔的水位在S1——S2之间,当水塔水位低于水塔下限水位开关S2时,则水塔下限液位开关S2为ON,则驱动电机M开始工作,向水塔供水。当S2为OFF时,表示水塔水位高于水塔下限水位。当水塔液面高于水塔上限水位开关S1时,则S1为ON,电机M停止抽水。当水塔水位低于下限水位时,同时水池水位也低于下限水位时,电机M不能启动。

总结

这一周的设计实习就这样结束了,在这短暂的实训时间里,经过老师、同学的指导,我获益匪浅,学习了不少关于自己专业方面的知识。

在完成项目期间,我们组的分工明确,有负责编程的,有负责报告找资料,有负责画电路图的……虽说分工明确,但在完成项目过程中遇到些麻烦的话组员之间还是相互配合相互帮助尽量让每个学员学到更多的专业知识,使每个组员更上一个层次。实训期间,我找资料,但这并不是说我在其他组员做他们任务时置之不理,与我无关。我在旁边和组员一起,参与其中的讨论分析,并会不时帮助他们完成任务。而同样我在做我的任务时,他们也会经常帮我解决一些我无法解决的问题。这样,我们组在完成这两个项目还是比较顺利的。

我做的这个题目是有关与PLC系统理论与实践相结合的设计。在此时对以前学习的知识的挑战与突破。在对这个设计的材料搜索进行独立搜索时,对于办公软件的应用有了进一步的提高。同时在对搜集的材料进行整核,结合所学理论知识,以及实际应用操作的情况下,提高了实际操作和独立解决问题的能力。

通过这次设计实践。让我更熟练的掌握了PLC软件的简单编程方法,对于PLC的工作原理和使用方法也有了更深刻的理解。在理论的运用中,也提高了我的工程素质。刚开始学习PLC软件时,由于我对一些细节的不加重视,当我把自己想出来的一些认为是对的程序运用到梯形图编辑时,问题出现了。转换成指令表后则显示不出很多正确的指令程序,这主要是因为我没有把理论和实践相结合,缺乏动手能力而造成的结果,最后通过老师的纠正和自己的实际操作,终于把正确的结果做了出来,同样也看清了自己的不足之处。

如今设计是做完了,可是我的学习之路还没有完,这次实训让不仅学习了不少与自己专业相关的知识,而且还懂得了团队的力量,并且让自己更相信一分努力一分收获,积极的学习态度在以后的学习、工作中是永远缺少不了的!并明白人这一辈子不能仅仅局限于那一点点满足感,要放眼望去,通过去参与各种实践,提升自己的动手能力,创造属于自己的未来。

参考文献

[1] 廖常初.《PLC基础及应用》.北京机械工业出版社,2004

[2] 王兆义.《可编程序控制器教程》.北京机械工业出版社 2005

[3] 张万忠. 《可编程控制器应用技术》. 北京:化学工业出版社,2001

[4] 方承远 . 《工厂电气控制技术》. 北京:机械工业出版社,2007

[5] 肖峰.《PLC编程100例》. 北京:中国电力出版社,2009

[6] 张桂香. 《电气控制与PLC应用》. 北京:化学工业出版社,2003

[7] 吕景泉.《可编程序控制器技术教程》.北京:高等教育出版社,2000

[8] 李俊季、赵黎明. 《可编程控制应用技术实训指导》. 北京:化学工业出版

社,2001

[9]天科TKPLC-A实验装置实验手册

[10]、《S7-200可编程序控制器手册》,西门子技术服务中心,四川省机械研究设计院,2000.9

[11]、王永华《现代电器控制及PLC应用技术》第2版,,北京航空航天大学出版社,

20

水塔水位检测控制系统的设计

摘要:本文采用PLC进行主控制,在水箱上安装一个自动测水位装置。利用水的导电性连续地全天候地测量水位的变化,把测量到的水位变化转换成相应的电信号,主控台对接收到的信号进行数据处理,完成相应的水位显示、故障报警信息显示、实时曲线和历史曲线的显示,使水位保持在适当的位置。 关键词:可编程逻辑控制器(PLC)自动控制系统水塔水位

Abstract

In the modern time, the Full-automatic washer is entering every family. The article introduces a new decelerating clutch, which is used in fully-auto washing machine, it can improve the current technology, simplify structure, it is also helpful to reduce cost and increases reliability.The thesis simply discusses the application research on water tower water level auto control system. It analyzes the limitation on the pre-designation of water tower water level auto control system, and devises the advanced plan. To be proved in the practice, the water tower water level auto control system is compatible for all kinds of liquids, and can throw into the effective production.

Keywords: programmable logic controllers (PLC) Auto Control System, Water Level Water Tower

摘要: ............................................................................................................................................................... - 1 - 关键词: ........................................................................................................................................................... - 1 - Abstract ........................................................................................................................................................... - 1 -

前言 ....................................................................................................................................................................... 2

第 1 章水塔水位控制系统方案设计 ................................................................................................................. 3

1.1 方案设计原则 ....................................................................................................................................... 3

1.2 系统的整体设计要求 ........................................................................................................................... 3

1.3 控制系统的设计 ................................................................................................................................... 4

1.3.1继电器控制系统 ........................................................................................................................ 4

1.3.2单片机控制 ................................................................................................................................ 4

1.3.3工业控制计算机控制 ................................................................................................................ 4

1.3.4可编程序控制器控制 ................................................................................................................ 4

第 2 章水塔水位控制系统的硬件设计 ............................................................................................................. 6

2.1 PLC的基本结构 .................................................................................................................................... 6

2.2 PLC 机型选择 ....................................................................................................................................... 8

2.3PLC容量选择 .......................................................................................................................................... 9

2.4 I/O 模块的选择 ................................................................................................................................. 10

2.5 电源模块的选择 .................................................................................................................................. 11

2.6水塔水位的工作流程: ...................................................................................................................... 12

第3章水塔水位控制系统软件设计 ................................................................................................................. 13

3.1PLC输入 /输出信号及地址分配 ........................................................................................................ 14

3.2主电路的设计 .................................................................................................................................. - 16 -

3.3水塔水位控制系统的PLC控制流程图 .......................................................................................... - 16 -

3.6系统调试 .......................................................................................................................................... - 17 - 总结 ................................................................................................................................................................. - 19 -

参考文献 ............................................................................................................................................................. 20

前言

可编程控制器(PLC)是以计算机技术为核心的通用自动化控制装置,它的功能性强,可靠性高,编程简单,使用方便,体积小巧,近年来在工业生产中得到广泛的应用,被誉为当代工业自动化主要支柱之一。现今社会,自动化装置无所不在,在控制技术需求的推动下,控制理论本身也取得了显著的进步。水塔水位的监测和控制,再也不需要人工进行操作。实践证明,自动化操作,具有不可替代的应用价值。水塔水位自动控制器,具有适应各种液体液位的检测和控制的功能,设计中分析了利弊,考虑了各种液体的阻值大小,是可以投入实际生产的产品。

第 1 章水塔水位控制系统方案设计

1.1 方案设计原则

整个设计过程是按工艺流程设计,为设备安装、运行和保护检修服务,设计的编写按照国家关于电气自动化工程设计中的电气设备常用基本图形符号(GB4728)及其他相关标准和规范编写。设计原则主要包括:工作条件:工程对电气控制线路提供的具体资料,系统在保证安全、可靠、稳定、快速的前提下,尽量做到经济、合理、合用,减小设备成本。在方案的选择、元器件的选型时更多的考虑新技术、新产品。控制由人工控制到自动控制,由模拟控制到微机控制,使功能的实现由一到多而且更加趋于完善。

对于本课题来说,液体混合系统部分是一个较大规模工业控制系统的改适升级,控制装置需要根据企业设备和工艺现况来构成并需尽可能的利用旧系统中的元器件。对于人机交互方式改造后系统的操作模式应尽量和改造前的相类似,以便于操作人员迅速掌握。从企业的改造要求可以看出在新控制系统中既需要处理模拟量也需要处理大量的开关量。系统的可靠性要高。人机交互界面友好,应具备数据储存和分析汇总的能力。

要实现整个液体混合控制系统的设计,需要从怎样实现多个电磁阀的开关以

及电动机启动的控制这个角度去考虑,现在就这个问题的如何实现以及选择怎样 的方法来确定系统方案。

1.2 系统的整体设计要求

在水塔水位控制过程中,整体控制要求如下:

当水池液体位于下限液位开关S1,S1此时为ON,电磁阀打开,开始往水池里注水,当4S以后,若水池液位没有超过水池下限液位开关时,则系统发出报警,若系统正常,此时水池下限位开关S4为OFF,表示水位高于下限水位。当水位液面高于上限水位,则S2为ON,电磁阀关闭。当水塔水位低于水塔下限水位时,则水塔下限水位开关S3为ON,水泵开始工作,向水塔供水,当S3为OFF

时,则水塔上限水位S4为OFF,水泵停止。当水塔水位低于下限水位,同时水池水位也低于下限水位时,水泵不能启动。

1.3 控制系统的设计

1.3.1继电器控制系统

控制功能是用硬件继电器实现的。继电器串接在控制电路中根据主电路中的电压、电流、转速、时间及温度等参量变化而动作,以实现电力拖动装置的自动控制及保护。系统复杂,在控制过程中,如果某个继电器损坏,都会影响整个系统的正常运行,查找和排除故障往往非常困难,虽然继电器本身价格不太贵,但是控制柜的安装接线工作量大,因此整个控制柜价格非常高,灵活性差,响应速度慢。

1.3.2单片机控制

单片机作为一个超大规模的集成电路,机构上包括 CPU、存储器、定时器和多种输入/输出接口电路。其低功耗、低电压和很强的控制功能,成为功控领域、尖端武器、日常生活中最广泛的计算机之一。但是,单片机是一片集成电路,不能直接将它与外部 I/O信号相连。要将它用于工业控制还要附加一些配套的集成电路和 I/O接口电路,硬件设计、制作和程序设计的工作量相当大。

1.3.3工业控制计算机控制

工控机采用总线结构,各厂家产品兼容性强,有实时操作系统的支持,在要求快速、实用性强、功能复杂的领域中占优势。但工控机价格较高,将它用于开关量控制有些大材小用。且其外部I/O接线一般都用于多芯扁平电缆和插头、插座,直接从印刷电路板上引出,不如接线端子可靠。

1.3.4可编程序控制器控制

可编程控制器配备各种硬件装置供用户选择,用户不用自己设计和制作硬件装置,只须确定可编程序控制器的硬件配制和设计外部接线图,同时采用梯形图语言编

程,用软件取代继电器电器系统中的触点和接线,通过修改程序适应工艺条件的变化。

可编程控制器(PLC)从上个世纪 70 年代发展起来的一种新型工业控制系统,起初它主要是针对开关量进行逻辑控制的一种装置,可以取代中间继电器、时间继电器等构成开关量控制系统。随着30 多年来微电子技术的不断发展,PLC也通过不断的升级换代大大增强了其功能。现在 PLC 已经发展成为不但具有逻辑控制功能、还具有过程控制功能、运动控制功能和数据处理功能、连网通讯功能等多种性能,是名符其实的多功能控制器。由PLC为主构成的控制系统具有可靠性高、控制功能强大、性价比高等优点,是目前工业自动化的首选控制装置。故选择PLC来实施本次设计。

1.开关量的逻辑控制

这是 PLC 最基本、最广泛的应用领域,它取代传统的继电器电路,实现逻辑控制、顺序控制,既可用于单台设备的控制,也可用于多机群控及自动化流水线。如注塑机、印刷机、订书机械、组合机床、磨床、包装生产线、电镀流水线等。

2.运动控制

PLC 可以用于圆周运动或直线运动的控制,世界上各主要 PLC 厂家的产品几乎都有运动控制功能,广泛用于各种机械、机床、机器人、电梯等场合。

3.闭环过程控制

过程控制是指对温度、压力、流量等模拟量的闭环控制。作为工业控制计算机,PLC 能编制各种各样的控制算法程序,完成闭环控制。PID 调节是一般闭环控制系统中用得较多的调节方法。过程控制在冶金、化工、热处理、锅炉控制等场合有非常广泛的应用。

4.数据处理

现代 PLC 具有数学运算(含矩阵运算、函数运算、逻辑运算)、数据传送、数据转换、排序、查表、位操作等功能,可以完成数据的采集、分析及处理。数据处理一般用于大型控制系统,如无人控制的柔性制造系统;也可用于过程控制系统,如造纸、冶金、食品工业中的一些大型控制系统。

5.通信及联网

PLC通信含 PLC间的通信及 PLC与其它智能设备间的通信。随着计算机控

制的发展,工厂自动化网络发展得很快,各PLC厂商都十分重视 PLC的通信功能,纷纷推出各自的网络系统。新近生产的PLC 都具有通信接口,通信非常方便。根据本控制系统的控制要求应该选择可编程序控制器控制。

第 2 章水塔水位控制系统的硬件设计

2.1 PLC的基本结构

PLC是以微处理器为核心的计算机控制系统。如图2.1.2所示

图2.1.2

1、中央处理单元(CPU)

PLC的中央处理器与一般的计算机系统一样,是PLC的控制中枢,其性能决定了PLC的性能。它按PLC中程序赋予的功能有条不紊地进行工作。

2、存储器(RM/ROM)

存储器是具有记忆功能的半导体电路,主要用来存放系统程序、用户程序和工作数据等。PLC中使用的存储器由只读存储器(ROM)、只读存储器(ROM)及可擦除只读存储器(EPROM)组成。存储器是衡量PLC性能的一个重要指标。

3、I/O接口

输入接口一般由数据输入寄存器、选通电路和中断请求逻辑电路构成,负责微处理器及外部设备交换信息。它接受来自现场检测不见(如限位开关、操作按钮、选择开关、行程开关)以及其他一些传感器输出的开关量或模拟量(要通过模数变换进入机内)等各种状态控制信号,并存入输入映像寄存器。

输入接口采用光电耦合电路将PLC与现场设备隔离起来,以提高PLC的抗干扰能力。输入接口电路通常有两类:一类为直流输入型,另一类是交流输入型。

输出接口模块是PLC与现场设备之间的连接部件,用来将输出信号送给控制对象。其作用是将中央处理单元送出的弱电控制信号转换成现场需要的强电信号并输出,以驱动电磁阀、接触器、电动机等被控设备的执行元件。

4、I/O扩展接口

小型的PLC输入输出接口都是与中央处理单元CPU制造在一起的。为了满足被控设备输入输出点数较多的要求,常需要扩展数字量输入输出模块;为了满足模拟量控制的需要,常需要扩展模拟量输入输出模块,如A/D、D/A转换模块等。I/O扩展接口就是为连接各种扩展模块而设计的。

5、通讯接口

通讯接口用于PLC与编程器、计算机、变频器、触摸屏以及其他PLC等智能设备之间的连接,以实现PLC与智能设备之间的数据传送。

6、编程器

编程器主要有两种。一种是PLC专用编程器,有手持式和台式等。另一种是基于个人计算机系统的PLC编程器。

7、电源

电源部件将交流电源转换成供PLC内部需要的直流电源。它的好坏直接影响PLC的功能和可靠性,因此目前大部分PLC均采用开关式稳压电源供电,同时还向各种扩展模块提供24V直流电源。

2.2 PLC 机型选择

机型选择的基本原则是在满足控制功能要求的前提下,保证系统工作可靠、维护使用方便及最佳的性能价格比。具体应考虑的因素如下所述。

1.结构合理

对于工艺过程比较固定、环境条件较好、维修量较小的场合,选用整体式结构的 PLC;否则,选用模块式结构的 PLC,物料混合控制系统的设计选用整体式结构的 PLC 能够达到要求。

2.功能强、弱适当

对于开关量控制的工程项目,若控制速度要求不高,一般选用低档的 PLC,西门子公司的 S7-200 系列机或欧姆龙公司的 COM1。

3.机型统一

PLC 的结构分为整体式和模块式两种。整体式结构把 PLC 的 I/O 和 CPU 放在一块印刷电路板上,并封装在一个壳体内,省去了插接环节,因此体积小、价格便宜。但由于整体式结构的 PLC 功能有限,只适用于控制要求比较简单的系统。一般大型的控制系统都使用模块式结构,这样功能易扩展,比整体式灵活。一个大型企业选用 PLC 时,尽量要做到机型统一。由于同一机型的 PLC,其模块可互为备用,以便备件的采购和管理;另外,功能及编程方法统一,有利于技术人员的培训;其外部设备通用也有利于资源共享。若配备了上位计算机,可把各独立系统的多台 PLC 联成一个多级分布式控制相互通信,集中协调管理。物料混合控制系统控制要求比较简单选择整体式结构的 PLC。

4.是否在线编程

PLC 的特点之一是使用灵活。当被控设备的工艺过程改变时,只需用编程器重新修改程序,就能满足新的控制要求,给生产带来很大方便。PLC 的编程分为离线编程和在线编程两种。离线编程的 PLC,其主机和编程器共用物料混合控制系统采用离线编程。

5.PLC 的环境适应性

由于 PLC 是直接用于工业控制的工业控制器,生产厂家都把它设计成能在恶劣

的环境条件下可靠地工作。尽管如此,每种 PLC 都有自己的环境技术条件,用户在选用时,特别是在设计控制系统时,对环境条件要进行充分的考虑。一般 PLC及其外部电路(I/O 模块、辅助电源等)都能在下列环境条件下可靠工作: 温度:工作温度 0~55℃,最高为 60℃

储存温度: -40℃~+85℃

湿度:相对湿度 5%~95%(无凝结霜)

振动和冲击:满足国际电工委员会标准

电源:交流 220V,允许变化范围为-15%~+15%,频率为 47~53Hz

瞬间停电保持 l0ms

环境:周围空气不能混有可燃性、爆炸性和腐蚀性气体

对于需要应用在特殊环境下的 PLC,要根据具体的情况进行合理的选择。

2.3PLC 容量选择

PLC 容量包括两个方面:一是 I/O 的点数;二是用户存储器的容量(字数)。PLC容量的选择除满足控制要求外,还应留有适当的裕量,以做备用。根据经验, 在选择存储容量时,一般按实际需要的10%~25%考虑裕量。对于开关量控制系统,存储器字数为开关量 I/O乘以 8;对于有模拟量控制功能的 PLC,所需存储器字数为模拟内存单元数乘以100。通常,一条逻辑指令占用存储器一个字。计时、计数、移位及算术运算、数据传输等指令占用存储器两个字。各种指令占存储器的字数可查阅PLC产品使用手册。 I/O点数也应留有适当裕量。由于目前I/O点数较多的 PLC价格也较高,若备用的 I/O点的数量太多,将使成本增加。根据被控对象的输入信号和输出信号的总点数,并考虑到今后的调整和扩充,通常I/O点数按实际需要的10%~15%考虑备用量。

2.4 I/O 模块的选择

PLC 是一种工业控制系统,它的控制对象是工业生产设备或工业生产过程,

它的工作环境是工业生产现场。它与工业生产过程的联系是通过I/O接口模块可

以检测被控生产过程的各种参数,并以这些现场数据作为控制器对被控制对象进

行控制的依据。同时控制器又通过 I/O接口模块将控制器的处理结果送给工业

生产过程中的被控设备,驱动各种执行机构来实现控制。外部设备或生产过程中

的信号电平各种各样,各种机构所需的信息电平也是各种各样的,而PLC的 CPU

所处理的信息只能是标准电平,所以 I/O接口模块还需实现这种转换。PLC 从

现场收集的信息及输出给外部设备的控制信号都需经过一定距离。为了确保这些

信息的正确无误,PLC 的 I/O 接口模块都具有较好的抗干扰能力。根据实际需

要,PLC 相应有许多种 I/O接口模块,包括开关量输入模块、开关量输出模块、

模拟量输入模块及模拟量输出模块,可以根据实际需要进行选择使用。

1确定 I/O点数

I/O点数的确定要充分的考虑到裕量,能方便地对功能进行扩展。对一个控

制对象,由于采用不同的控制方法或编程水平不一样,I/O点数就可能有所不同。

2.开关量 I/O

标准的 I/O接口用于同传感器和开关(如按钮、限位开关等)及控制(开/关)

设备(如指示灯、报警器、电动机起动器等)进行数据传输。典型的交流I/O

信号为 24~240V(AC),直流I/O信号为 5~24V(DC)。

3.选择开关量输入模块主要从下面两方面考虑:一是根据现场输入信号与PLC

输入模块距离的远近来选择电平的高低。一般 24V 以下属于低电平,其传输距

离不宜太远。如 12V 电压模块一般不超过10m,距离较远的设备选用较高电压

模块比较可靠。二是高密度的输入模块,如32 点输入模块,能允许同时接通的

点数取决于输入电压和环境温度。一般同时接通的点数不得超过总输入点数的

60%。

4.选择开关量输出模块时应从以下三个方面来考虑:一是输出方式选择。输出

模块有三种输出方式:继电器输出、晶闸管输出、晶体管输出。其中,继电器输

出价格便宜,使用电压范围广,导通压降小,承受瞬时过电压和过电流的能力强,

且有隔离作用。但继电器有触点,寿命较短,且响应速度较慢,适用于动作不频

繁的交/直流负载。当驱动电感性负载时,最大开闭频率不得超过 1Hz。晶闸管

输出(交流)和晶体管输出(直流)都属于无触点开关输出,适用于通断频繁的

感性负载。感性负载在断开瞬间会产生较高反电压,必须采取抑制措施。二是输

出电流的选择。模块的输出电流必须大于负载电流的额定值,如果负载电流较大,

输出模块不能直接驱动时,应增加中间放大环节。对于电容性负载、热敏电阻负

载,考虑到接通时有冲击电流,要留有足够的余量。三是允许同时接通的输出点

数。在选用输出点数时,不但要核算一个输出点的驱动能力,还要核算整个输出

模块的满负荷负载能力,即输出模块同时接通点数的总电流值不得超过模块规定

的最大允许电流值。

2.5 电源模块的选择

电源模块的选择一般只需考虑输出电流。电源模块的额定输出电流必须大于处理

器模块、I/O模块、专用模块等消耗电流的总和。以下步骤为选择电源的一规则:

1.确定电源的输入电压;

2.将框架中每块 I/O 模块所需的总背板电流相加,计算出 I/O 模块所需的总

背板电流值;

3.I/O模块所需的总背板电流值再加上以下各电流:

1)框架中带有处理器时,则加上处理器的最大电流值;

2)当框架中带有远程适配器模块或扩展本地I/O适配器模块时,应加上其最

大电流值。

4.如果框架中留有空槽用于将来扩展时,可做以下处理;

1)列出将来要扩展的 I/O模块所需的背板电流;

2)将所有扩展的 I/O模块的总背板电流值与步骤。

5.在框架中是否有用于电源的空槽,否则将电源装到框架的外面。

6.根据确定好的输入电压要求和所需的总背板电流值,从用户手册中选择合适

的电源模块。具体应考随着 PLC 技术的发展,PLC 产品的种类越来越多,而且

功能也日益完善。PLC 的种类繁多,其结构、性能、容量、指令系统、编程方式、

价格等各有不同,当然使用场合也有所不同。因此选择合理的PLC对提高 PLC

控制系统技术经济指标意义重大。因此在选择机型时不仅要满足其功能要求及维

护等方面的虑:

1)合理的结构形式

2)安装方式的选择

3)相当的功能要求

4)系统可靠性的要求

综上所述,根据控制系统要求选择 S7-200 系列 PLC,S7-200 系列 PLC属于小

型整体式结构的 PLC,本机自带 RS485 通信接口,内置电源和 I/O 接口,

它的结构小巧,运行速度快,可靠性高,具有极其丰富的指令系统和扩展模块,

实时性和通信能力强大,便于操作,易于掌握,性价比高,是中小规模控制系统

的理想控制设备。

2.6水塔水位的工作流程:

当水池液体位于下限液位开关S1,S1此时为ON,电磁阀打开,开始往水池里

注水,当4S以后,若水池液位没有超过水池下限液位开关时,则系统发出报警,

若系统正常,此时水池下限位开关S4为OFF,表示水位高于下限水位。当水位

液面高于上限水位,则S2为ON,电磁阀关闭。当水塔水位低于水塔下限水位

时,则水塔下限水位开关S3为ON,水泵开始工作,向水塔供水,当S3为OFF

时,则水塔上限水位S4为OFF,水泵停止。当水塔水位低于下限水位,同时水

池水位也低于下限水位时,

水泵不能启动。如图2.1.

第3章水塔水位控制系统软件设计

3.1PLC输入 /输出信号及地址分配

根据上述水塔水位控制要求的分析,PLC的输入信号有蓄水池水位上下限液

位传感器信号,水塔水箱水位上下限液位传感器信号。PLC的输出信号有进水口

阀门控制电磁阀、水泵电机控制接触器、蓄水池和水塔水箱水位故障报警信号灯。

由上述PLC输入 /输出信号分析可知,选择S7-200系列的PLC即可满足控制要

求,其输入 /输出地址分配如表1所示。

表1 I/O分配图

1

3.2主电路的设计

3.3水塔水位控制系统的PLC控制流程图

根据设计要求,控制流程图如图所示

3.6系统调试

保持水池的水位在S3——S4之间,当水池水位低于下限液位开关S3,此时S3为ON,电磁阀打开,开始往水池里注水,当5S以后,若水池水位没有超过水池下限液位开关S3时,则系统发出警报;若系统正常运行,此时水池下限液位开关S3为OFF,表示水位高

于下限水位。当页面高于上限水位S4时,则S4为ON,电磁阀关闭。

2)保持水塔的水位在S1——S2之间,当水塔水位低于水塔下限水位开关S2时,则水塔下限液位开关S2为ON,则驱动电机M开始工作,向水塔供水。当S2为OFF时,表示水塔水位高于水塔下限水位。当水塔液面高于水塔上限水位开关S1时,则S1为ON,电机M停止抽水。当水塔水位低于下限水位时,同时水池水位也低于下限水位时,电机M不能启动。

总结

这一周的设计实习就这样结束了,在这短暂的实训时间里,经过老师、同学的指导,我获益匪浅,学习了不少关于自己专业方面的知识。

在完成项目期间,我们组的分工明确,有负责编程的,有负责报告找资料,有负责画电路图的……虽说分工明确,但在完成项目过程中遇到些麻烦的话组员之间还是相互配合相互帮助尽量让每个学员学到更多的专业知识,使每个组员更上一个层次。实训期间,我找资料,但这并不是说我在其他组员做他们任务时置之不理,与我无关。我在旁边和组员一起,参与其中的讨论分析,并会不时帮助他们完成任务。而同样我在做我的任务时,他们也会经常帮我解决一些我无法解决的问题。这样,我们组在完成这两个项目还是比较顺利的。

我做的这个题目是有关与PLC系统理论与实践相结合的设计。在此时对以前学习的知识的挑战与突破。在对这个设计的材料搜索进行独立搜索时,对于办公软件的应用有了进一步的提高。同时在对搜集的材料进行整核,结合所学理论知识,以及实际应用操作的情况下,提高了实际操作和独立解决问题的能力。

通过这次设计实践。让我更熟练的掌握了PLC软件的简单编程方法,对于PLC的工作原理和使用方法也有了更深刻的理解。在理论的运用中,也提高了我的工程素质。刚开始学习PLC软件时,由于我对一些细节的不加重视,当我把自己想出来的一些认为是对的程序运用到梯形图编辑时,问题出现了。转换成指令表后则显示不出很多正确的指令程序,这主要是因为我没有把理论和实践相结合,缺乏动手能力而造成的结果,最后通过老师的纠正和自己的实际操作,终于把正确的结果做了出来,同样也看清了自己的不足之处。

如今设计是做完了,可是我的学习之路还没有完,这次实训让不仅学习了不少与自己专业相关的知识,而且还懂得了团队的力量,并且让自己更相信一分努力一分收获,积极的学习态度在以后的学习、工作中是永远缺少不了的!并明白人这一辈子不能仅仅局限于那一点点满足感,要放眼望去,通过去参与各种实践,提升自己的动手能力,创造属于自己的未来。

参考文献

[1] 廖常初.《PLC基础及应用》.北京机械工业出版社,2004

[2] 王兆义.《可编程序控制器教程》.北京机械工业出版社 2005

[3] 张万忠. 《可编程控制器应用技术》. 北京:化学工业出版社,2001

[4] 方承远 . 《工厂电气控制技术》. 北京:机械工业出版社,2007

[5] 肖峰.《PLC编程100例》. 北京:中国电力出版社,2009

[6] 张桂香. 《电气控制与PLC应用》. 北京:化学工业出版社,2003

[7] 吕景泉.《可编程序控制器技术教程》.北京:高等教育出版社,2000

[8] 李俊季、赵黎明. 《可编程控制应用技术实训指导》. 北京:化学工业出版

社,2001

[9]天科TKPLC-A实验装置实验手册

[10]、《S7-200可编程序控制器手册》,西门子技术服务中心,四川省机械研究设计院,2000.9

[11]、王永华《现代电器控制及PLC应用技术》第2版,,北京航空航天大学出版社,

20


相关内容

  • 物联网工程本科毕业论文选题
  • 毕业论文(设计) 题 目 学 院 学 院 专 业 学生姓名 学 号 年级 级 指导教师 毕业教务处制表 毕业 毕业二〇一五年 十二月一 日 毕业 物联网工程毕业论文选题(1435个) 一.论文说明 本写作团队致力于毕业论文写作与辅导服务,精通前沿理论研究.仿真编程.数据图表制作,专业本科论文300起 ...

  • [煤矿安全]项目课程标准
  • <煤矿安全>课程标准 一.概述 (一)课程性质 <煤矿安全>是一门理论性与实践性较强的主要专业课程,是煤矿开采专业.通风专业必修课程,涵盖到中职和五年制高职:主要是培养学生在矿井瓦斯.煤尘.火灾防治方面的专业技能,以及矿山救护方面的现场急救技能.避免在煤炭生产过程中发生重大事 ...

  • 实验室楼宇智能化技术课程设计
  • 楼宇智能化技术课程设计 方 案 介 绍 实验楼楼宇智能化技术课程设计 一.设计题目 <楼宇智能化技术课程设计>是一个综合性和实践性很强的教学环节,要求 学生应用专业知识,根据设计流程,掌握工程设计的方法.培养学生分析问题.解决问题的能力. 二.设计任务及要求 为电力系实验楼设计一个安全防 ...

  • 电气行业标准课程论文
  • 电气行业标准课程论文 <GB/T 29781-2013(电动汽车充电站通用要求)>标准解析 专业:电气工程及其自动化 班级: 电气123班 学号: 1609120313 姓名: 朋 学 友 2015年11月 <GB/T 29781-2013(电动汽车充电站通用要求)>标准解析 ...

  • 地下停车场监控系统
  • 组态软件实训(论文) 题目: 地下停车场监控系统 院(系): 专业班级: 学 号: 学生姓名: rio 指导教师: 教师职称: 副教授 起止时间:2013-06-17至2013-06-28 课程设计(论文)任务及评语 目 录 第1章 课程设计的方案 . ....................... ...

  • 包装运输方案和培训计划
  • 附件1-10:设备的包装和运输方案 1.设备发运方案 货运监控是项目实施过程中一个极其重要的环节,赛尔网络将做好本项目设备从发货到交货的一系列过程中货物的正常流通.我们将从发货开始建立一套可行.有效的货运监控机制,以保证货物及时安全到达指定的位置,从而保证整个项目的工期能够按时完成,避免一些意外发生 ...

  • 嵌入式系统课程设计选题要求及题目
  • 嵌入式系统课程设计-选题要求及课题 1.嵌入式系统课程设计时长两星期,要求学生分组进行课程设计,每组学生人数为2-3人(可在不超过3人的范围内由指导教师具体规定),报告雷同超过60%者,成绩都记不及格! 2.学生需要在附后的设计题目总表中进行选题,原则上需要在6月17号前完成选题,并开始课程设计工作 ...

  • 井盖防盗报警系统
  • 视频监控安装与综合布线 课程设计报告 设计题目: 井盖防盗系统设计 专 业 电子信息 班 级 092 学 号 [1**********]8 学生姓名 保昆 指导教师 赵昌赣 设计时间 2011-2012学年下学期 教师评分 2012年 月 日 目 录 1.概述 ................... ...

  • 火车车速监控系统设计
  • EPC 和RFID 技术 课程设计(论文) 火车车速监控系统设计 院(系)名称 专 学 学 指生导姓教业班级 号 名 师 电子与信息工程学院 物联网121班 120402007 薛红见 贾旭 副教授 起 止 时 间: 2015.12.21-2016.1.1 课程设计(论文)任务及评语 院(系):电子 ...

  • 南邮 控制系统课程设计
  • <控制系统课程设计>教学大纲 课程编号:B0564011C 课内周数:2周 课程类别:□通识基础 □学科基础 □专业基础 ■专业 适用专业:自动化 一.所涉及的课程及知识点 涉及课程:自动控制原理.现代控制理论.计算机控制与仿真.电力电子技术.运动控制系统.过程控制.单片机原理与接口技术 ...