不同前处理方法测定植物油中重金属的研究

2012年第37卷第7期中国油脂

85

检测分析

不同前处理方法测定植物油中重金属的研究

倪张林,汤富彬,屈明华

(中国林业科学研究院亚热带林业研究所,国家林业局经济林产品质量检验检测中心(杭州),浙江富阳311400)

摘要:考察了湿法消解、干法灰化、微波消解3种不同前处理方法对植物油中重金属含量测定结果的影响。结果表明,硝酸-过氧化氢-高氯酸湿法消解为植物油前处理的最佳方法。采用石墨炉原子吸收光谱法测定植物油中的铅、镉、铬,线性范围内相关性良好,相关系数大于0.99,加标回收94.5%、84.9%,RSD 分别为8.5%、5.3%、9.1%,0.89、率分别为88.2%、检出限分别为6.21、1.99μg /kg。该方法耗时短、操作简单,应用于植物油中重金属含量的测定,结果令人满意。关键词:植物油;前处理方法;重金属;石墨炉原子吸收光谱法中图分类号:TS225;TS201.6

文献标志码:A

文章编号:1003-7969(2012)07-0085-03

Determination of heavy metals content in vegetable oils with different preprocessing methods NI Zhanglin ,TANG Fubin ,QU Minghua

(Quality Testing Center for None -wood Forest Products of State Forestry Administration (Hangzhou ),

Research Institute of Subtropical Forestry ,CAF ,Fuyang 311400,Zhejiang ,China )

Abstract :Effects of three preprocessing methods ,including wet digestion ,ashing digestion and microwave digestion on the determination of heavy metals in vegetable oil were studied.After comparison ,wet diges-tion method with HNO 3-H 2O 2-HClO 4was the best ,and graphite aurnace atomic absorption spectrome-try (GFAAS )was used to determine lead ,cadmium and chromium in vegetable oil.This method had a good linear relation (r >0.99).The recovery rate of lead ,cadmium and chromium were 88.2%,94.5%and 84.9%,respectively ,the relative standard deviation were 8.5%,5.3%and 9.1%,respectively ,and the detection limits were 6.21,0.89and 1.99μg /kg,respectively.Key words :vegetable oil ;preprocessing methods ;heavy metal ;GFAAS

随着工业的迅速发展,生产中排放的废水、废气、废渣中的无机元素不可避免进入土壤、地下水和地表水;化肥、农药中也含有微量的重金属元素,它们将从土壤中迁移到植物中,从而进入植物油;植物油在生产、加工、运输、贮存过程中,都有可能受到重金属元素的污染。因此,需要建立一种简单、快速、灵敏度高的方法对植物油中重金属的含量进行测定。

植物油中99%以上为脂肪酸等有机组分,其特性决定了在重金属测定的前处理过程中的复杂性。

收稿日期:2011-09-27;修回日期:2012-03-20

基金项目:中央级公益性科研院所基本科研业务费专项资金(RISF6151)

作者简介:倪张林(1982),男,实验师,主要从事食品中重金mail )nizhanglin@yahoo.cn 。属检测方面的研究工作(E-

目前植物油的前处理技术主要有湿法消解灰化

[2]

[1]

、干法、石

[3]

、微波消解等方法,这几种方法各有利弊。

[4]

植物油中重金属测定方法主要有分光光度法墨炉原子吸收光谱法法

[7]

[5]

、原子荧光法[6]、电化学

、电感耦合等离子体发射光谱法(ICP -

[9]

AES )[8]、电感耦合等离子体质谱法(ICP -MS ),

其中石墨炉原子吸收光谱法具有检出限低、灵敏度高、选择性好等优点。本文旨在通过比较不同前处理方法,采用石墨炉原子吸收光谱法,建立较为简快捷、准确的用于植物油中重金属的测定方法。单、11.1

材料与方法主要原料、试剂

植物油样品,购于当地超市和农贸市场;重金属标准溶液(铅0.5mg /kg,镉0.1mg /kg,铬0.1mg /

86

CHINA OILS AND FATS 2012Vol. 37No. 7

kg )及GBW10016标准茶叶(铅(1.50ʃ 0.20)μg /g,镉(0.062ʃ 0.004)μg /g,铬(0.45ʃ 0.10)μg /g),购于国家标准物质中心;硝酸、过氧化氢(BVIII )、高氯酸、磷酸二氢铵,优级纯。1.2

主要仪器、设备

Multiwave 3000微波消解仪,奥地利Anton Paar 公司;M6型原子吸收光谱仪(配石墨炉),美国Thermo Fisher 公司;陶瓷电热板,德国IKA 公司;AB104-S 万分位天平;马弗炉;其他玻璃器皿(均经过30%硝酸浸泡24h 以上)。1.3样品前处理方法1.3.1

湿法消解

湿法消解1:硝酸-高氯酸体系。称取约0.5g 植物油样品于平底长颈消解瓶中,加入15mL 混合酸(硝酸与高氯酸体积比为9ʒ 1),加盖放置过夜,次日于电热板上180ħ 加热,当瓶内混合酸剩余5mL 左右时,取下瓶子稍冷却,补加5mL 混合酸,继续180ħ 加热,期间不断补加混合酸,直至消解液清亮为止,

然后赶酸至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。

湿法消解2:硝酸-过氧化氢体系。称取约0.5g 植物油样品于平底长颈消解瓶中,加入15mL 硝酸,加盖放置过夜,次日于电热板上180ħ 加热,当瓶内硝酸剩余1mL 左右时,取下瓶子稍冷却,加入5mL 过氧化氢和5mL 硝酸,继续180ħ 加热,期间不断补加过氧化氢,直至消解液清亮为止,然后赶酸至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。

湿式消解3:硝酸-过氧化氢-高氯酸体系。称取约0.5g 植物油样品于平底长颈消解瓶中,加入15mL 硝酸,加盖放置过夜,次日于电热板上180ħ 加热,当瓶内硝酸剩余5mL 左右时,取下瓶子稍冷却,

加入10mL 过氧化氢,再于180ħ 加热至过氧化氢剧烈反应结束,取下瓶子稍冷却,加入1mL 高氯酸,于240ħ 继续加热至冒白烟,180ħ 下赶酸至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。1.3.2

微波消解

称取约0.5g 植物油样品于消化管中,加入10mL 硝酸、5mL 过氧化氢,加盖放置过夜,次日于电热板上180ħ 预消解约3h ,然后密封好消化管,放入微波消解仪中,消解90min 后,180ħ 赶酸至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。

1.3.3干法灰化

称取约0.5g 植物油样品于瓷坩埚中,先于电热板上180ħ 炭化至无烟,移入马弗炉(500ʃ 25)ħ 灰化8h ,冷却,加入1mL 混合酸(硝酸与高氯酸体积比为9ʒ 1),于电热板上180ħ 加热至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。1.4

原子吸收光谱仪测定

测定条件:铅、镉、铬的波长分别为283.3、228.8、357.9nm ,光谱带宽均为0.5nm ,灯电流分别为10、8、8mA ,进样体积均为20μL ,测定铅时需加入基体改进剂磷酸二氢铵5μL 。石墨炉升温程序见表1。

表1

石墨炉升温程序元素干燥灰化原子化净化铅110ħ

900ħ 1300ħ 2500ħ 20/30s ﹡10/20s 0/4s 0/3s 镉110ħ 300ħ 900ħ 2500ħ 20/30s 10/20s 0/4s 0/3s 铬

100ħ 1800ħ 2300ħ 2500ħ 20/30s

10/20s

0/4s

0/3s

注:﹡x /y表示x 秒升温到固定值维持y 秒。

2结果与讨论

2.1

不同前处理方法的比较

表2为不同前处理方法试剂消耗和消解耗时,

表3为不同前处理方法的加标回收测定结果。

表2不同前处理方法下试剂消耗和消解耗时比较

处理方法试剂消耗/mL

消解耗时/h

湿法消解130(混合酸:硝酸与高氯酸体积比为9ʒ 1)10湿法消解2

20(硝酸)

20(过氧化氢)6

15(硝酸)

湿法消解310(过氧化氢)5

1(高氯酸)

干法灰化1(混合酸:硝酸与高氯酸体积比为9ʒ 1)14微波消解

10(硝酸)5(过氧化氢)

8

由表2可知,采用干法灰化试剂消耗最少,其次为微波消解和湿法消解3,湿法消解2试剂消耗最多。在消解耗时方面,干法灰化耗时最长,湿法消解3耗时最短。一般认为,微波消解比较省时,但由于油脂的特殊性,微波消解需要较长时间的预消解,否则进入微波消解仪容易引起爆管,另外消解完毕还需要赶酸,所以在消解耗时上没有明显优势。

2012年第37卷第7期

表3

元素铅镉铬

湿法消解1回收率82.381.580.2

RSD 10.89.611.4

中国油脂

87

%

微波消解回收率90.295.780.6

RSD 7.95.18.7

RSD 19.512.68.8

不同前处理方法的加标回收测定结果(n =6)

湿法消解3回收率88.294.584.9

RSD 8.55.39.1

干法灰化回收率72.556.673.3

RSD 8.68.39.4

湿法消解2回收率72.687.565.1

由表3可知,干法灰化的加标回收率都在80%以下,这可能因为高温下灰化时间过长,导致元素损失。采用微波消解和湿法消解3处理的植物油样品加标回收率和RSD 结果都较为满意。

综上,选择湿法消解3(硝酸-过氧化氢-高氯酸体系)作为植物油样品重金属含量测定的前处理方法。2.2

线性范围及方法检出限

各元素的回归方程、线性范围、相关系数与方法检出限见表4。方法检出限=3ˑ 样品空白吸光度的标准差/标准曲线斜率,再根据称样量和定容体积换算为本方法的检出限。

表4各元素的回归方程、线性范围及方法检出限元素

回归方程

线性范围/相关系检出限/

(μg /L)数r (μg /kg)铅y =0.0042x +0.00850 400.99936.21镉y =0.1223x +0.00450 40.99820.89铬y =0.0842x +0.0222

0 4

0.9969

1.99

2.3样品测定结果

选取8种植物油样品,采用硝酸-过氧化氢-

高氯酸湿法消解处理样品,在选定的仪器工作条件下对3种重金属元素进行测定,结果见表5。

表5不同植物油中铅、镉、铬含量的测定结果(n =3)

铅/(μg /g)

镉/(μg /g)铬/(μg /g)

瓶装菜籽油ND 0.012ND 散装菜籽油0.0610.0140.058瓶装大豆油0.029ND ND 散装大豆油0.0720.009ND 瓶装花生油0.0280.0090.006散装一级油0.1560.032ND 瓶装山茶籽油ND ND ND 山茶籽毛油0.0590.033ND GBW10016标准茶叶

1.380.058

0.40由表5可知,所测定的植物油中,除散装一级油铅含量超过《食用油卫生标准》

[10]

外,其余重金属

含量都较低,瓶装油中重金属含量较散装油和毛油低,说明精炼后这些重金属元素能得到较好地去除。采用GBW10016标准茶叶作为质控样品,由测定结

果可知,3种元素的测定值均在参考值范围之内,说明该方法可靠。3

通过不同前处理方法对植物油中重金属含量测定结果的比较,提出了采用硝酸-过氧化氢-高氯酸湿法消解处理植物油样品,石墨炉原子吸收光谱法测定3种重金属元素,此方法操作简单,结果准确,灵敏度高。该法测定的植物油样品中铅、镉、铬的加标回收率分别为88.2%、

94.5%、84.9%,RSD 分别为8.5%、5.3%、9.1%,方法检出限分别为6.21、0.89、1.99μg /kg,能够满足植物油中痕量重金属的测定。参考文献:

[1]杜洪凤,沈月华,张坤.湿法消解-原子荧光光谱法同时

测定油脂样品中砷和汞[J ].中国卫生检验杂志,2005,15(9):1060-1061.

[2]杨桂珍,杨建男.灰化消解-极谱法测定油料中五个重金

属元素[

J ].理化检验:化学分册,2007,43(4):267-269.[3]赵荣林,凌凤香,孙振国,等.微波消解-氢化物发生原

子荧光法测定重油中的砷和汞[J ].光散射学报,2010,22(1):90-96.

[4]周祥德.菜籽油中铁铜含量及测定方法[J ].福建分析

测试,

2004,13(2):1962-1964.[5]李志国,郑琳琳.应用石墨炉法测定食用油中铅含量

[J ].食品研究与开发,2007,28(8):134-136.

[6]ABBASI S ,ALLAHYARI M ,TAHERIMASLAK Z ,et al.

New determination of lead in edible oil and water samples by high selective adsorptive stripping voltammetry with SPADNS [J ].Int J Electrochem Sci ,2009(4):602-613.[7]叶嘉荣,郭新东,罗海英,等.微波消解-氢化物原子荧

光法测定鱼油中铅[

J ].广州化工,2006,34(2):52-54.[8]郭岚,谢明勇,鄢爱平,等.电感耦合等离子发射光谱法

用于植物油多元素同步测定研究[J ].光谱学与光谱分析,

2007,27(11):2345-2348.[9]陈向阳,余淑媛,刘贤杰,等.电感耦合等离子体质谱法

测定精油中砷、

钡、铋、镉、铬、铅、锑、汞含量[J ].分析试验室,

2009,28(S1):251-253.[10]GB 2716—2005,食用油卫生标准[

S ].

2012年第37卷第7期中国油脂

85

检测分析

不同前处理方法测定植物油中重金属的研究

倪张林,汤富彬,屈明华

(中国林业科学研究院亚热带林业研究所,国家林业局经济林产品质量检验检测中心(杭州),浙江富阳311400)

摘要:考察了湿法消解、干法灰化、微波消解3种不同前处理方法对植物油中重金属含量测定结果的影响。结果表明,硝酸-过氧化氢-高氯酸湿法消解为植物油前处理的最佳方法。采用石墨炉原子吸收光谱法测定植物油中的铅、镉、铬,线性范围内相关性良好,相关系数大于0.99,加标回收94.5%、84.9%,RSD 分别为8.5%、5.3%、9.1%,0.89、率分别为88.2%、检出限分别为6.21、1.99μg /kg。该方法耗时短、操作简单,应用于植物油中重金属含量的测定,结果令人满意。关键词:植物油;前处理方法;重金属;石墨炉原子吸收光谱法中图分类号:TS225;TS201.6

文献标志码:A

文章编号:1003-7969(2012)07-0085-03

Determination of heavy metals content in vegetable oils with different preprocessing methods NI Zhanglin ,TANG Fubin ,QU Minghua

(Quality Testing Center for None -wood Forest Products of State Forestry Administration (Hangzhou ),

Research Institute of Subtropical Forestry ,CAF ,Fuyang 311400,Zhejiang ,China )

Abstract :Effects of three preprocessing methods ,including wet digestion ,ashing digestion and microwave digestion on the determination of heavy metals in vegetable oil were studied.After comparison ,wet diges-tion method with HNO 3-H 2O 2-HClO 4was the best ,and graphite aurnace atomic absorption spectrome-try (GFAAS )was used to determine lead ,cadmium and chromium in vegetable oil.This method had a good linear relation (r >0.99).The recovery rate of lead ,cadmium and chromium were 88.2%,94.5%and 84.9%,respectively ,the relative standard deviation were 8.5%,5.3%and 9.1%,respectively ,and the detection limits were 6.21,0.89and 1.99μg /kg,respectively.Key words :vegetable oil ;preprocessing methods ;heavy metal ;GFAAS

随着工业的迅速发展,生产中排放的废水、废气、废渣中的无机元素不可避免进入土壤、地下水和地表水;化肥、农药中也含有微量的重金属元素,它们将从土壤中迁移到植物中,从而进入植物油;植物油在生产、加工、运输、贮存过程中,都有可能受到重金属元素的污染。因此,需要建立一种简单、快速、灵敏度高的方法对植物油中重金属的含量进行测定。

植物油中99%以上为脂肪酸等有机组分,其特性决定了在重金属测定的前处理过程中的复杂性。

收稿日期:2011-09-27;修回日期:2012-03-20

基金项目:中央级公益性科研院所基本科研业务费专项资金(RISF6151)

作者简介:倪张林(1982),男,实验师,主要从事食品中重金mail )nizhanglin@yahoo.cn 。属检测方面的研究工作(E-

目前植物油的前处理技术主要有湿法消解灰化

[2]

[1]

、干法、石

[3]

、微波消解等方法,这几种方法各有利弊。

[4]

植物油中重金属测定方法主要有分光光度法墨炉原子吸收光谱法法

[7]

[5]

、原子荧光法[6]、电化学

、电感耦合等离子体发射光谱法(ICP -

[9]

AES )[8]、电感耦合等离子体质谱法(ICP -MS ),

其中石墨炉原子吸收光谱法具有检出限低、灵敏度高、选择性好等优点。本文旨在通过比较不同前处理方法,采用石墨炉原子吸收光谱法,建立较为简快捷、准确的用于植物油中重金属的测定方法。单、11.1

材料与方法主要原料、试剂

植物油样品,购于当地超市和农贸市场;重金属标准溶液(铅0.5mg /kg,镉0.1mg /kg,铬0.1mg /

86

CHINA OILS AND FATS 2012Vol. 37No. 7

kg )及GBW10016标准茶叶(铅(1.50ʃ 0.20)μg /g,镉(0.062ʃ 0.004)μg /g,铬(0.45ʃ 0.10)μg /g),购于国家标准物质中心;硝酸、过氧化氢(BVIII )、高氯酸、磷酸二氢铵,优级纯。1.2

主要仪器、设备

Multiwave 3000微波消解仪,奥地利Anton Paar 公司;M6型原子吸收光谱仪(配石墨炉),美国Thermo Fisher 公司;陶瓷电热板,德国IKA 公司;AB104-S 万分位天平;马弗炉;其他玻璃器皿(均经过30%硝酸浸泡24h 以上)。1.3样品前处理方法1.3.1

湿法消解

湿法消解1:硝酸-高氯酸体系。称取约0.5g 植物油样品于平底长颈消解瓶中,加入15mL 混合酸(硝酸与高氯酸体积比为9ʒ 1),加盖放置过夜,次日于电热板上180ħ 加热,当瓶内混合酸剩余5mL 左右时,取下瓶子稍冷却,补加5mL 混合酸,继续180ħ 加热,期间不断补加混合酸,直至消解液清亮为止,

然后赶酸至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。

湿法消解2:硝酸-过氧化氢体系。称取约0.5g 植物油样品于平底长颈消解瓶中,加入15mL 硝酸,加盖放置过夜,次日于电热板上180ħ 加热,当瓶内硝酸剩余1mL 左右时,取下瓶子稍冷却,加入5mL 过氧化氢和5mL 硝酸,继续180ħ 加热,期间不断补加过氧化氢,直至消解液清亮为止,然后赶酸至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。

湿式消解3:硝酸-过氧化氢-高氯酸体系。称取约0.5g 植物油样品于平底长颈消解瓶中,加入15mL 硝酸,加盖放置过夜,次日于电热板上180ħ 加热,当瓶内硝酸剩余5mL 左右时,取下瓶子稍冷却,

加入10mL 过氧化氢,再于180ħ 加热至过氧化氢剧烈反应结束,取下瓶子稍冷却,加入1mL 高氯酸,于240ħ 继续加热至冒白烟,180ħ 下赶酸至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。1.3.2

微波消解

称取约0.5g 植物油样品于消化管中,加入10mL 硝酸、5mL 过氧化氢,加盖放置过夜,次日于电热板上180ħ 预消解约3h ,然后密封好消化管,放入微波消解仪中,消解90min 后,180ħ 赶酸至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。

1.3.3干法灰化

称取约0.5g 植物油样品于瓷坩埚中,先于电热板上180ħ 炭化至无烟,移入马弗炉(500ʃ 25)ħ 灰化8h ,冷却,加入1mL 混合酸(硝酸与高氯酸体积比为9ʒ 1),于电热板上180ħ 加热至近干,冷却后,采用1%硝酸少量多次洗涤定容至25mL ,上机备用;同时做样品空白和加标实验。1.4

原子吸收光谱仪测定

测定条件:铅、镉、铬的波长分别为283.3、228.8、357.9nm ,光谱带宽均为0.5nm ,灯电流分别为10、8、8mA ,进样体积均为20μL ,测定铅时需加入基体改进剂磷酸二氢铵5μL 。石墨炉升温程序见表1。

表1

石墨炉升温程序元素干燥灰化原子化净化铅110ħ

900ħ 1300ħ 2500ħ 20/30s ﹡10/20s 0/4s 0/3s 镉110ħ 300ħ 900ħ 2500ħ 20/30s 10/20s 0/4s 0/3s 铬

100ħ 1800ħ 2300ħ 2500ħ 20/30s

10/20s

0/4s

0/3s

注:﹡x /y表示x 秒升温到固定值维持y 秒。

2结果与讨论

2.1

不同前处理方法的比较

表2为不同前处理方法试剂消耗和消解耗时,

表3为不同前处理方法的加标回收测定结果。

表2不同前处理方法下试剂消耗和消解耗时比较

处理方法试剂消耗/mL

消解耗时/h

湿法消解130(混合酸:硝酸与高氯酸体积比为9ʒ 1)10湿法消解2

20(硝酸)

20(过氧化氢)6

15(硝酸)

湿法消解310(过氧化氢)5

1(高氯酸)

干法灰化1(混合酸:硝酸与高氯酸体积比为9ʒ 1)14微波消解

10(硝酸)5(过氧化氢)

8

由表2可知,采用干法灰化试剂消耗最少,其次为微波消解和湿法消解3,湿法消解2试剂消耗最多。在消解耗时方面,干法灰化耗时最长,湿法消解3耗时最短。一般认为,微波消解比较省时,但由于油脂的特殊性,微波消解需要较长时间的预消解,否则进入微波消解仪容易引起爆管,另外消解完毕还需要赶酸,所以在消解耗时上没有明显优势。

2012年第37卷第7期

表3

元素铅镉铬

湿法消解1回收率82.381.580.2

RSD 10.89.611.4

中国油脂

87

%

微波消解回收率90.295.780.6

RSD 7.95.18.7

RSD 19.512.68.8

不同前处理方法的加标回收测定结果(n =6)

湿法消解3回收率88.294.584.9

RSD 8.55.39.1

干法灰化回收率72.556.673.3

RSD 8.68.39.4

湿法消解2回收率72.687.565.1

由表3可知,干法灰化的加标回收率都在80%以下,这可能因为高温下灰化时间过长,导致元素损失。采用微波消解和湿法消解3处理的植物油样品加标回收率和RSD 结果都较为满意。

综上,选择湿法消解3(硝酸-过氧化氢-高氯酸体系)作为植物油样品重金属含量测定的前处理方法。2.2

线性范围及方法检出限

各元素的回归方程、线性范围、相关系数与方法检出限见表4。方法检出限=3ˑ 样品空白吸光度的标准差/标准曲线斜率,再根据称样量和定容体积换算为本方法的检出限。

表4各元素的回归方程、线性范围及方法检出限元素

回归方程

线性范围/相关系检出限/

(μg /L)数r (μg /kg)铅y =0.0042x +0.00850 400.99936.21镉y =0.1223x +0.00450 40.99820.89铬y =0.0842x +0.0222

0 4

0.9969

1.99

2.3样品测定结果

选取8种植物油样品,采用硝酸-过氧化氢-

高氯酸湿法消解处理样品,在选定的仪器工作条件下对3种重金属元素进行测定,结果见表5。

表5不同植物油中铅、镉、铬含量的测定结果(n =3)

铅/(μg /g)

镉/(μg /g)铬/(μg /g)

瓶装菜籽油ND 0.012ND 散装菜籽油0.0610.0140.058瓶装大豆油0.029ND ND 散装大豆油0.0720.009ND 瓶装花生油0.0280.0090.006散装一级油0.1560.032ND 瓶装山茶籽油ND ND ND 山茶籽毛油0.0590.033ND GBW10016标准茶叶

1.380.058

0.40由表5可知,所测定的植物油中,除散装一级油铅含量超过《食用油卫生标准》

[10]

外,其余重金属

含量都较低,瓶装油中重金属含量较散装油和毛油低,说明精炼后这些重金属元素能得到较好地去除。采用GBW10016标准茶叶作为质控样品,由测定结

果可知,3种元素的测定值均在参考值范围之内,说明该方法可靠。3

通过不同前处理方法对植物油中重金属含量测定结果的比较,提出了采用硝酸-过氧化氢-高氯酸湿法消解处理植物油样品,石墨炉原子吸收光谱法测定3种重金属元素,此方法操作简单,结果准确,灵敏度高。该法测定的植物油样品中铅、镉、铬的加标回收率分别为88.2%、

94.5%、84.9%,RSD 分别为8.5%、5.3%、9.1%,方法检出限分别为6.21、0.89、1.99μg /kg,能够满足植物油中痕量重金属的测定。参考文献:

[1]杜洪凤,沈月华,张坤.湿法消解-原子荧光光谱法同时

测定油脂样品中砷和汞[J ].中国卫生检验杂志,2005,15(9):1060-1061.

[2]杨桂珍,杨建男.灰化消解-极谱法测定油料中五个重金

属元素[

J ].理化检验:化学分册,2007,43(4):267-269.[3]赵荣林,凌凤香,孙振国,等.微波消解-氢化物发生原

子荧光法测定重油中的砷和汞[J ].光散射学报,2010,22(1):90-96.

[4]周祥德.菜籽油中铁铜含量及测定方法[J ].福建分析

测试,

2004,13(2):1962-1964.[5]李志国,郑琳琳.应用石墨炉法测定食用油中铅含量

[J ].食品研究与开发,2007,28(8):134-136.

[6]ABBASI S ,ALLAHYARI M ,TAHERIMASLAK Z ,et al.

New determination of lead in edible oil and water samples by high selective adsorptive stripping voltammetry with SPADNS [J ].Int J Electrochem Sci ,2009(4):602-613.[7]叶嘉荣,郭新东,罗海英,等.微波消解-氢化物原子荧

光法测定鱼油中铅[

J ].广州化工,2006,34(2):52-54.[8]郭岚,谢明勇,鄢爱平,等.电感耦合等离子发射光谱法

用于植物油多元素同步测定研究[J ].光谱学与光谱分析,

2007,27(11):2345-2348.[9]陈向阳,余淑媛,刘贤杰,等.电感耦合等离子体质谱法

测定精油中砷、

钡、铋、镉、铬、铅、锑、汞含量[J ].分析试验室,

2009,28(S1):251-253.[10]GB 2716—2005,食用油卫生标准[

S ].


相关内容

  • 植株中重金属含量测定方法的研究现状_郑方超
  • DOI:10.14088/j.cnki.issn0439-8114.2012.20.011 第51卷第20期第年期月20102012 湖北农业科学Vol.51No.20 Oct.,2012 HubeiAgriculturalSciences 植株中重金属含量测定方法的研究现状 郑方超,崔 婷,李容萱 ...

  • 科研能力训练
  • 科研能力训练 请从下列题目中,选择一项进行实验设计.也可以根据现实生产实际中遇到的生物学问题,设计一项研究.内容格式参照四川农业大学本科生开题报告的格式要求.(完成时间:2012年1月13日前,将试验设计发至[email protected] 1.稀土元素对植物根系发育的影响 植物根系是植物从其生活环 ...

  • 嘉应学院园林生态学实验指导书
  • 嘉应学院<园林生态学>实验指导书 实验1 环境因子对植物形态结构的影响 一.实验目的 1.掌握生长在不同环境下的植物形态结构的特点,理解植物形态结构是如何适应于其生境特征.掌握从植物外部形态及生长,生境特点上鉴别植物耐荫性的方法. 2.理解植物器官的结构特点对植物生长发育及其环境适应的意 ...

  • 中药中的重金属及其检测和去除方法
  • 2010年8月第27卷第4期Aug .2010, Vol.27No.4天津中医药 Tianjin Journal of Traditional Chinese Medicine 351 ·综述· 中药中的重金属及其检测和去除方法* 郭伟 (天津中医药大学第一附属医院制剂室,天津300193) 关键词 ...

  • 铯对空心莲子草的毒害及6-BA对其缓解机制的研究
  • 铯对空心莲子草的毒害及6-BA 对其缓解机制的研究 农学 2006级 朱从桦 指导教师 李立芹 讲师 摘要:当铯的浓度小于10mg/L时,空心莲子草植株外伤症状为轻度伤害:植物细胞内的SOD 酶活性有所升高.随着铯浓度增加,导致植株生长缓慢,植株根系受损,叶片色素含量下降,细胞膜透性增大,MDA 含 ...

  • 8种木本植物对矿渣中重金属的吸收与富集研究_张富运
  • 2014年3月ENVIRONMENTALSCIENCE AND MANAGEMENT Mar.2014 文章编号:1674-6139(2014)03-0168-03 8种木本植物对矿渣中重金属的吸收与富集研究 张富运,陈永华,吴晓芙,梁希 (中南林业科技大学,环境科学与工程研究中心,湖南长沙4100 ...

  • 铅污染土壤稳定化试验
  • 摘 要 随着全球经济快速发展,铅污染状况日益严峻.铅是重金属污染土壤中分布较广.具强蓄积性的环境污染物.土壤中铅的天然来源是风化岩石中的矿物.多年来,尽管人们对三废(废气.废水.废渣)的排放已采取严格的控制措施,由于频繁的人类活动,随着矿山开采.金属冶炼加工.IT制造.生活污水排放.污水灌溉.污泥使 ...

  • 重金属污染土壤修复示范工程实施方案
  • **重金属污染土壤修复示范工程 实施方案 目 录 第一章 项目实施指导思想及原则 ------------------------------------------------------------- 1 1.1指导思想 ------------------------------------- ...

  • 新墙河区草本植物重金属含量的测定
  • 第26卷第1期Vol. 26 No. 1分析科学学报 J OU RNAL OF ANAL YTICAL SCIENCE 2010年2月Feb. 2010 DOI 编码:10. 3969/j. issn. 100626144. 2010. 01. 030 新墙河区草本植物重金属含量的测定 肖 华3, ...