移动通信基站电磁辐射在垂直方向的分布
施东风 祝 莉 孙沙青
(浙江省辐射环境监测站, 浙江 杭州 310012
摘要 针对居住在城市移动通信基站附近的居民日益关注的电磁辐射问题,选择移动通信基站周围环境中最高层与基站天线高度相当的建筑物作为电磁辐射监测点,并在基站正常运行的状况下,对选取的点位进行电磁辐射监测,分析其电磁辐射在垂直方向上的分布。结果显示,监测点电场强度的大小与监测点和移动基站发射天线的俯角有密切的关系。
关键词 移动通信基站 电磁辐射 电场强度 功率密度
1
The distribution of electromagnetic radiation made by the mobile communication stations
in the vertical direction Shi Dongfeng, Zhu Li, Sun Shaqing. (Zhejiang Radiation Monitoring Stations, Hangzhou Zhejiang 310012)
Abstract: The issues of electromagnetic radiation made by the mobile communication stations located in the city are more often concerned by people. In this research, the authors chose the buildings which have the same height with the antennas of the stations as the monitor point to detect the electromagnetic radiation, and analyze the distribution of electromagnetic radiation in the vertical direction. The work reveals that the electric field intensity is closely related to the depression angle of the antennas.
Keywords: Mobile communication stations Electromagnetic radiation Electric field intensity Power density
近年来,随着浙江经济、交通、旅游等事业的迅速发展,移动电话业务增长十分迅猛,特别是杭州、宁波、温州等经济强市的市区,为了更好地满足用户的通信要求,移动通信基站更是分布在各个角落。另一方面,公众的环境意识不断增强,他们对通信基站周围的电磁辐射问题也越来越关心。而在实际监测工作中,选择基站周围有代表性的监测点位,能最大可能的掌握基站对周围环境的电磁辐射影响。为了解移动通信基站的电磁辐射特征,笔者对杭州市不同通信基站周围的电磁辐射环境现状进行了监测分析,以求对基站的监测及评价提出一定的建议。 1 基站概况
本文监测的3个移动通信基站分别是杭州联通西湖灯饰市场基站(以下简称西湖灯饰) 、富阳永兴房地产公司基站(以下简称富阳永兴)、杭州移动省邮电规划设计院基站(以下简称省邮电设计院),各基站参数列于表1。 2 监测仪器及监测条件 2.1 监测仪器
采用德国Narda 公司生产的ERM-300型宽频带各向同性场强仪,频率响应10 MHz~18 GHz;量程0.6~800.0 V/m。
1
第一作者:施东风,男,1979年生,工程师 主要从事环境影响评价和辐射环境监测工作。
表1 各移动通信基站参数
2.2 监测条件
本文采用的3个移动通信基站的具体监测条件详见表2。
表2 移动通信基站的监测条件
2.3 监测点位
各基站监测点位均选择在基站天线主瓣方向,且和基站天线高度相当的楼房楼顶、临基站一侧的窗外或楼梯口;测量高度为离地1.7 m(或离立足点1.7 m) [1]。 3 监测结果及分析
富阳永兴、西湖灯饰、省邮电设计院3个基站电场强度监测结果见表3,电场强度随楼层的变化曲线见图1。
由表3可见,移动通信基站天线主瓣方向的射频综合电场强度相对比环境背景值要高,但各监测点的电场强度仍低于《电磁辐射防护规定》(GB8702-88)规定的环境总的电场强度限值12 V/m,符合环境保护的要求。
由图1能明显看出,随着监测点位高度的下降,即监测点位与基站天线所形成的俯角的变小,监测点的电场强度亦随之下降(有个别点位由于受到别的辐射源的影响而产生
一定的波动)[2, 3]。
表3 电磁辐射现场监测结果
图1 电场强度随楼层的变化示意图
根据以上结果分析,对于类似的移动通信基站,在现场监测时应注意点位的选择,尽量选择与天线主瓣方向正对、高度相当的点位,其结果能最大限度的反映基站对周围环境的电磁辐射影响程度。有利于提高对基站的评价、监测工作的效率。 4 结 语
通过对不同类型基站的监测结果分析,较好的掌握了移动通信基站产生的射频综合电场强度在垂直方向上的分布规律,即随着监测点位与基站天线所形成的俯角的变小,监测点的电场强度亦随之下降。这对于研究移动通信基站对周围电磁环境的影响
有现实的意义。 参考文献
[1] HJ/T10.2-1996.辐射环境保护管理导则 电磁辐射监测仪器和方法[S].
[2] 朱丹,戴继伟.移动通信基站的环境电磁辐射测量与分析[J].上海环境科学,1997,16(11):32-34. [3] 邹澎,侯均衡.高大建筑物对电磁辐射环境的影响[J].电波科学报,1990,5(4):50-54.
责任编辑:赵 多 (收到修改稿日期:2006-07-23)
版权所有
《环境污染与防治》杂志社
移动通信基站电磁辐射在垂直方向的分布
施东风 祝 莉 孙沙青
(浙江省辐射环境监测站, 浙江 杭州 310012
摘要 针对居住在城市移动通信基站附近的居民日益关注的电磁辐射问题,选择移动通信基站周围环境中最高层与基站天线高度相当的建筑物作为电磁辐射监测点,并在基站正常运行的状况下,对选取的点位进行电磁辐射监测,分析其电磁辐射在垂直方向上的分布。结果显示,监测点电场强度的大小与监测点和移动基站发射天线的俯角有密切的关系。
关键词 移动通信基站 电磁辐射 电场强度 功率密度
1
The distribution of electromagnetic radiation made by the mobile communication stations
in the vertical direction Shi Dongfeng, Zhu Li, Sun Shaqing. (Zhejiang Radiation Monitoring Stations, Hangzhou Zhejiang 310012)
Abstract: The issues of electromagnetic radiation made by the mobile communication stations located in the city are more often concerned by people. In this research, the authors chose the buildings which have the same height with the antennas of the stations as the monitor point to detect the electromagnetic radiation, and analyze the distribution of electromagnetic radiation in the vertical direction. The work reveals that the electric field intensity is closely related to the depression angle of the antennas.
Keywords: Mobile communication stations Electromagnetic radiation Electric field intensity Power density
近年来,随着浙江经济、交通、旅游等事业的迅速发展,移动电话业务增长十分迅猛,特别是杭州、宁波、温州等经济强市的市区,为了更好地满足用户的通信要求,移动通信基站更是分布在各个角落。另一方面,公众的环境意识不断增强,他们对通信基站周围的电磁辐射问题也越来越关心。而在实际监测工作中,选择基站周围有代表性的监测点位,能最大可能的掌握基站对周围环境的电磁辐射影响。为了解移动通信基站的电磁辐射特征,笔者对杭州市不同通信基站周围的电磁辐射环境现状进行了监测分析,以求对基站的监测及评价提出一定的建议。 1 基站概况
本文监测的3个移动通信基站分别是杭州联通西湖灯饰市场基站(以下简称西湖灯饰) 、富阳永兴房地产公司基站(以下简称富阳永兴)、杭州移动省邮电规划设计院基站(以下简称省邮电设计院),各基站参数列于表1。 2 监测仪器及监测条件 2.1 监测仪器
采用德国Narda 公司生产的ERM-300型宽频带各向同性场强仪,频率响应10 MHz~18 GHz;量程0.6~800.0 V/m。
1
第一作者:施东风,男,1979年生,工程师 主要从事环境影响评价和辐射环境监测工作。
表1 各移动通信基站参数
2.2 监测条件
本文采用的3个移动通信基站的具体监测条件详见表2。
表2 移动通信基站的监测条件
2.3 监测点位
各基站监测点位均选择在基站天线主瓣方向,且和基站天线高度相当的楼房楼顶、临基站一侧的窗外或楼梯口;测量高度为离地1.7 m(或离立足点1.7 m) [1]。 3 监测结果及分析
富阳永兴、西湖灯饰、省邮电设计院3个基站电场强度监测结果见表3,电场强度随楼层的变化曲线见图1。
由表3可见,移动通信基站天线主瓣方向的射频综合电场强度相对比环境背景值要高,但各监测点的电场强度仍低于《电磁辐射防护规定》(GB8702-88)规定的环境总的电场强度限值12 V/m,符合环境保护的要求。
由图1能明显看出,随着监测点位高度的下降,即监测点位与基站天线所形成的俯角的变小,监测点的电场强度亦随之下降(有个别点位由于受到别的辐射源的影响而产生
一定的波动)[2, 3]。
表3 电磁辐射现场监测结果
图1 电场强度随楼层的变化示意图
根据以上结果分析,对于类似的移动通信基站,在现场监测时应注意点位的选择,尽量选择与天线主瓣方向正对、高度相当的点位,其结果能最大限度的反映基站对周围环境的电磁辐射影响程度。有利于提高对基站的评价、监测工作的效率。 4 结 语
通过对不同类型基站的监测结果分析,较好的掌握了移动通信基站产生的射频综合电场强度在垂直方向上的分布规律,即随着监测点位与基站天线所形成的俯角的变小,监测点的电场强度亦随之下降。这对于研究移动通信基站对周围电磁环境的影响
有现实的意义。 参考文献
[1] HJ/T10.2-1996.辐射环境保护管理导则 电磁辐射监测仪器和方法[S].
[2] 朱丹,戴继伟.移动通信基站的环境电磁辐射测量与分析[J].上海环境科学,1997,16(11):32-34. [3] 邹澎,侯均衡.高大建筑物对电磁辐射环境的影响[J].电波科学报,1990,5(4):50-54.
责任编辑:赵 多 (收到修改稿日期:2006-07-23)
版权所有
《环境污染与防治》杂志社