全固态双脉冲激光器

电光调Q 双脉冲输出Nd:YAG全固态激光器

李峰 王君涛 殷苏勇 朱小磊*

(中国科学院上海光学精密机械研究所,

上海市全固态激光与应用重点实验室, 上海 201800)

摘要:文章设计了LD 双端面抽运传导冷却复合Nd:YAG晶体电光调Q 激光器,实现脉冲间隔可调的双Q 脉冲输出。用两个光纤耦合输出的LD 模块作为抽运源,BBO 晶体作为Q 开关,在一个泵浦周期内两次启动Q 开关,获得脉冲能量大于14 mJ/脉冲,脉宽 ≤18 ns,脉冲间隔200 μs-230 μs 可调的双Q 脉冲输出,激光器重复频率50Hz ,光-光转换效率达到24%。探索了用KD*P调Q 晶体开关实现稳定双脉冲输出的可行性,通过抑制压电环效应,消除子脉冲现象,最终获得脉冲能量约11mJ/脉冲,脉宽约≤18ns 。

关键字 激光技术;Nd:YAG激光器;双脉冲激光; KD*P调Q ;BBO 调Q 中图分类号:TN248.1 文献标识码 A

Electro-optical Q-switched Double-pulse Laser output Nd:YAG All Solid-State Laser Li Feng Wang Juntao Yin Suyong Zhu Xiaolei*

Shanghai Institute of Optics and Fine Mechanics,Chinese Academy of Sciences, Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques, Shanghai 201800, China

Abstract A LD dual-end pumped, conductively cooled, electro-optical Q-switched composite Nd:YAG laser is designed. Double-pulse laser output with adjustable pulse interval is achieved. By using two fiber-coupled LD modules as the pumping source, BBO crystal as the Q-switch, we acquire double-pulse laser output by opening the Q-switch twice in a pumping cycle time, and the laser is capable of producing two Q-switched 1064nm laser with the single pulse energy more than 14 mJ and pulse width less than 18 ns, the interval between the two pulses is adjustable from 200μs to 230μs at the repetition of 50 Hz, the optical-to-optical efficiency reaches 24%. Furthermore, we explore the feasibility of stable double-pulse laser output by using the Q-switched crystal KD*P, by suppressing the piezoelectric ring effect of KD*P, we

remove the sub-pulse phenomenon and obtain double-pulse laser output with 11 mJ per pulse and pulse width less than 18 ns.

Key words laser technology; Nd:YAG lasers; double-pulse laser; KD*P Q-switch; BBO Q-switch

OCIS codes: 140.3470; 140.3540; 140.3580; 280.1910

作者简介:李峰(1987--),男,硕士研究生,主要从事双脉冲激光器技术研究。E-mail :

导师简介:朱小磊(1966--),男,研究员,博士生导师,主要从事固体激光器技术及激光器应用系统等方面的研究。[email protected]

1 引言

双脉冲全固态激光器在大气环境监测、精细加工、动态全息成像等领域都有较大的应用需求[1~3]。研究表明,采用双激光脉冲打孔技术,在有效提高精细加工效率的同时,又能显著地改善激光打孔的质量[2]。但这种双激光脉冲打孔技术要求将调Q 双脉冲间隔控制在200 ns 以内,否则这种优势将很难体现,这对激光器的双脉冲控制技术提出了很高的要求[4]。此外,在动态全息检测领域,为了实现对快速事件发展过程的连续观察,则要求双脉冲激光输出激光器作为主动成像光源[3]。这种成像技术通常要求的双脉冲激光间隔为1 μs – 1000 μs之间,通过把微秒量级间隔的两个脉冲照明拍摄出来的两个全息图叠置在同一张全息底板上, 可以将被测物体的任何瞬态扰动都显现在双激光脉冲全息图的干涉条纹上,因而获得被测物体的动态信息。

调Q 双脉冲激光器的另外一个重要的应用是作为差分吸收大气探测激光雷达的光发射源或光泵浦源。2003年,美国NASA 研制成功的Ho:Tm:YLF双脉冲激光振荡器[5],利用最大抽运能量为3 J 的半导体激光阵列脉冲泵浦,采用一个泵浦周期两次打开调Q 开关技术实现中红外2.053 μm波长的双脉冲激光输出,直接用于大气探测。该激光振荡器输出两个能量相等调Q 脉冲,每个脉冲能量达到66 mJ。为了进一步提升单脉冲能量,又采用主振荡器功率放大技术,最终获得600 mJ 的调Q 双脉冲激光输出。2005年该课题组报道的Ho:Tm:LuLF晶体

激光器[6],已将调Q 双脉冲激光器输出脉冲能量提升到1 J量级。2008年,在德国研制的差分吸收雷达系统CO 2-IPDA(integrated path differential absorption lidar)系统中 [7]器在10 Hz重复频率下,经过放大器放大后获得最大脉冲能量100 mJ的1064 nm双脉冲输出,脉冲宽度8 ns。

本文研究工作瞄准差分吸收大气探测激光雷达泵浦源的应用需求,设计了电光调Q 双脉冲全固态激光器,比较研究了BBO 与KD*P晶体开关调Q 双脉冲实现的可行性和性能差异。采用BBO 晶体开关实现双脉冲输出,可获得较高的脉冲能量及光-光转换效率。而KD*P晶体开关由于存在严重的压电环效应,极易出现子脉冲现象,对调Q 双脉冲的稳定输出带来严重的负面影响。

2 实验理论分析和实验装置

图1是实验设计的

Nd:YAG激光器原理光路图。出于方便以后种子激光注入锁定应用的考虑,谐振腔设计采用平行平面腔结构,几何腔长约为1100mm ,U 形排布利于结构紧凑稳定。

图1 LD双端泵浦Nd :YAG 双脉冲激光器原理光路图

Fig.1 Schematic of LD dual-end pumped double-pulsed Nd:YAG laser

QWP:quarter wave plate; QS:Q-switch P:polarizer

激光增益介质采用直径为4 mm、双端键合的YAG/Nd:YAG/YAG复合结构晶体棒,晶体总长30 mm,其中掺杂部分长度为20 mm, Nd 3+掺杂浓度为0.5at.%。

采用这种复合晶体结构能有效的减小端面效应及热焦距,在实验允许的最大抽运功率内,由热透镜的焦距公式[8] , 得到晶体的热焦距大于1600 mm 。由铟箔包裹的Nd:YAG晶体紧密夹持在紫铜热沉上,并置于谐振腔中央位置。激光器后腔镜为一平面全反镜,输出耦合镜的初始透过率为60%。根据实验需要,电光调Q 开关分别采用BBO 晶体开关,或KD*P晶体开关。泵浦源采用两个光纤耦合的LD 模块,其最大输出功率为150 W ,中心波长808 nm ,光纤芯径600 μm,数值孔径NA 为0.22。抽运光耦合系统为焦距为1:2.5的双镜系统,耦合效率大于95%,与振荡模体积实现较好的重合。抽运LD 模块的驱动重复频率为50 Hz ,驱动电流占空比约为2.2%,且可调。

根据Magni 理论[9],激光谐振腔中的固体增益介质可以等效成一个焦距随抽运功率动态变化的热透镜。在实验设计的谐振腔结构中,增益介质处于谐振腔中央位置,此时,增益介质处振荡模光斑大小随热透镜焦距值的变化有图2所示的分布规律,显然当热透镜焦距值小于300 mm时,谐振腔将进入非稳区,热透镜焦距值大于300 mm时,振荡模光斑直径的变化非常平缓,有利于输出能量稳定。本文实验过程中,在抽运脉宽420 μs 的条件下,增益介质热焦距远大于300 mm,确保激光器远离非稳定工作区域。

图2 增益介质处振荡模光斑半径随热焦距变化规律

Fig.2 Radius variation of oscillation modes’ spot size with the change of focal length

激光器获得双脉冲输出的机制是合理控制抽运LD 的驱动电脉冲宽度与调Q 开关触发信号时序关系,即在一个抽运周期内,按特定的时序关系,两次开启电光开关,因而获得两个调Q 激光脉冲输出。在相对抽运LD 驱动电脉冲延时一段时间后,Q 开关第一次启动,消耗了增益介质内的反转粒子数,输出Q 脉冲。由于Q 开关的快速关闭,尽管LD 持续抽运,激光器低Q 值状态腔内完全抑制子脉冲的出现,增益介质反转粒子数重新积累,当达到与第一次Q 开关启动时反转值相当时,第二次启动Q 开关并获得调Q 激光脉冲,电驱动同时结束。调Q 双脉冲各自的能量大小及相互之间时间间隔可以通过改变LD 驱动电脉冲宽度及时序关系来主动控制,获得需要的结果。

3 实验结果及分析讨论

在电光晶体开关中,BBO 晶体只有微弱的压电环效应,其工作重复频率可以达到几十kHz 。实验过程中,为了获得稳定的200 μs 间隔双调Q 脉冲,我们首先采用BBO 晶体开关,在LD 泵浦一个周期内,并在接近200 μs 的时间间隔内,使晶体开关两次承受加压-退压过程,以实现双调Q 脉冲的产生。

当抽运LD 的电脉冲宽度为420 μs ,BBO 晶体调Q 高压触发延时分别为220 μs和420 μs时,对应60%的输出耦合率,实验获得了图3所示的双Q 脉冲序列示波照片,从图3(a )上看,前后两个脉冲的峰值基本相同,双脉冲间隔严格受触发信号间隔控制。从图3(b )可以看出,双脉冲的脉冲周期为20 ms,对应重频50 Hz,由于双脉冲间隔200us ,所以在宽X 的时间轴上不能清晰的分辨出双脉冲。改变两个高压触发信号的延时差,就能获得不同时间间隔的调Q 双脉冲输出。而调Q 双脉冲输出能量的大小及相对比值则直接受抽运能量大小的影响,在初始的小泵浦输入条件下,第一个脉冲的能量大于第二个脉冲,随着抽运功率的增大,第二个脉冲能量增大幅度大于第一个脉冲,直到两个脉冲输出能量基本接近。在输入116 mJ抽运光的条件下,获得最大脉冲能量输出大于14 mJ/脉冲。图4为实验测得双调Q 激光器的输入-输出曲线,显示了在特定驱动电流脉冲宽度的条件下,双脉冲能量的变化趋势,在抽运输入能量105 mJ—120 mJ范围内,双脉冲能量基本保持相同。

图3 (a )BBO 调Q 双脉冲图 (b )BBO 调Q 双脉冲周期图

Fig.3 (a )Double pulse laser output using BBO Q-switch

图4双脉冲激光器的输入-输出曲线

Fig.4 Double pulse laser output at different pump energy

当抽运光脉冲的输入能量为108 mJ时,实验对双Q 脉冲的脉冲宽度值进行分别测量,结果见图5。第一个调Q 脉冲示波器显示的脉冲宽度约为18 ns ,第二个调Q 脉冲的脉冲宽度值约为17.5 ns,基本实现了两个脉冲宽度的一致。

(a ) (b )

图5双脉冲的瞬时脉冲波形 (a)第一个脉冲,(b)第二个脉冲

Fig.5 The temporal pulse profile of the double-pulse laser

(a)The first pulse, (b)the second pulse

图6给出该激光器输出平均功率随泵浦输入平均功率的变化曲线,对于T=60%的输出耦合率,当抽运电流脉冲宽度为420 μs时,该双Q 脉冲输出激光器的斜效率达到31%。在最大输出条件下,光-光转换效率接近24%,此时,用Spiricon M 2-200激光光束质量分析仪对激光光束质量M 2值进行测量,测量结果如图7所示,光束在x 轴、y 轴向的M 2值分别为M 22

图6 激光输出功率随抽运功率变化

Fig.6 Q-switched laser power as a function of pump power.

图7 光束质量(M2) 测量图

Fig.7 Measurement of laser beam quality(M2)

实验中,我们用KD*P调Q 晶体开关替代BBO 晶体开关研究双脉冲输出特性,由于KD*P晶体本身存在严重的压电环效应[10,11],原则上不适合200 μs间隔双脉冲输出应用。当抽运能量提高的一定水平时,出现子脉冲输出现象,参见图8, 即在第二次Q 开关打开信号达到之前,已有随机的调Q 子脉冲输出。产生这种现象的原因是实验中当第一个Q 高压完全退压后,由于压电环效应存在,KD*P晶体双折射存在弛豫消退的过程,对于420 μs泵浦脉宽系统,在第一个脉冲输出后的200 μs时间内,KD*P晶体开关处于非完全关闭状态,随着抽运的持续激光器能在第二次高压信号前多次达到阈值,因而输出调Q 子脉冲。

图8 KD*P调Q 输出的子脉冲包络

Fig.8 The pulse train from KD*P Q-switched laser

针对调Q 子脉冲形成的机制,实验中我们通过提高激光器振荡阈值,优化第一个调Q 信号延时时间,并降低泵浦输入能量来抑制200 μs周期内子脉冲的出现,最终在实验上获得了类似图3的无子脉冲的双调Q 脉冲序列稳定输出,最大双脉冲输出能量达到11 mJ/脉冲,调Q 脉冲宽度小于18 ns,激光器光光转换效率达到21.8%。

4 结论

在双端面抽运的传导冷却Nd :YAG 电光调Q 激光器中,插入BBO 晶体开关或KD*P晶体开关,在50 Hz重复频率条件下,采用在一个泵浦周期内两次启动晶体开关高压技术,成功实现了脉冲间隔在200 μs附近可调的调Q 双脉冲输出,前后两个脉冲的能量和脉冲宽度能够保持基本一致。实验结果显示,BBO 晶体开关比KD*P晶体开关更适合在双Q 脉冲输出机制激光器的应用。

文中针对KD*P晶体开关采取的抑制压电环效应引起的子脉冲技术,在相关激光器的研制中具有参考价值。

参考文献

1. G. J. Koch, B. W. Barnes, M. Petros et al..Coherent differential absorption lidar measurements of CO 2 [J].Appl. opt.,2004,43(26): 5092

~5099

2. K. Walther, M. Brajdic, E. W. Kreutz. Enhanced processing speed in laser drilling of stainless steel by spatially and temporally superposed pulsed Nd:YAG laser radiation[J]. The International Journal of Advanced Manufacturing Technology (2008) 35:895~899

3. Li Feng, Ni Xuxiang,Wu Bizhen et al..New method to realize double-pulse laser at high repetition[J]. Acta Photonica Sinica,1998,27(4):342~347 李峰,倪旭翔,吴碧珍等 实现高重复率双脉冲激光器的新方法[J].光子学报,1998,27(4):342~347

4. Wang xueJun,Meng Fanyu,Li Meng et al..Nanosecond dual pulse laser controlling method[J].Chiese J.lasers,2011,38(2):99~102

王学军,孟繁禹,李猛等 纳秒双脉冲激光的控制方法 [J].中国激光 2011,38

(2):99~102

5.Jirong Yu. 600-mJ, double-pulse 2-um laser[J].Opt.Lett.,2003, 28

(7):540~542

6.Songsheng Chen, Jirong Yu, Mulugeta Petros, et al..One-joule double-pulsed Ho:Tm:LuLF master-oscillator-power-amplifier (MOPA)

[C]. OSA/ASSP, February, 6 ,2005,Vienna Austrilia

7.Deutsches Zentrum f ür Luft-und Raumfahrt (DLR) Oberpfaffenhofen. Development of an OPO system at 1.57μm for integrated path DIAL measurement of atmospheric carbon dioxide[J].Appl. Phys.B,2008, 92:295~302

8.Yang Yongming ,Wen Jianguo ,Wang Shiyu et al..Focal length of the thermal lens in LD end-pumped Nd:YAG laser[J].Acta Photonica Sinica, 2005, 34

(12):1769~1772

杨永明,文建国,王石语等,LD 端面泵浦Nd:YAG激光器中的热透镜焦距,光子学报,2005,34(12):1769~1772

9.V.magni, Resonators for solid-state lasers with large-volume fundamental mode and high alignment stability[J]. Appl. Opt., 1986, 25(1):107~117

10.Tang Hao.Study on all-solid state green Laser with high repetition rate of electro-optic Q-switcher[D].Shanghai: Shanghai institution of optics and fine mechanics, 2009

唐昊 全固态高重复率电光调Q 绿光激光器特性研究[D]. 上海:上海光学精密机械研究所 2009

11.M.Roth,M.Tseitlin,N.Angert. Oxide crystals for electro-optic Q-switching of lasers. [J].Glass Physics and Chemistry, 2005, 31 (1): 86~85

实验创新点:

1.

2.

3. 通过一个抽运周期两次打开电光Q 快关,实现了调Q 双脉冲输出,并且实现了了脉冲间隔200 μs 附近可调,通过对泵浦脉宽以及调Q 触发时间的控制,实现了能量近似相等,两个脉冲脉宽近似相等的双脉冲输出。 文章对比分析了BBO 和KD*P调Q 双脉冲的实验差异,并结合两个调Q 晶体的自身差异,给出了分析解释。 KD*P晶体开关存在压电环效应,文章中抑制压电环效应引起的

子脉冲技术,在相关激光器的研制中具有参考价值。

电光调Q 双脉冲输出Nd:YAG全固态激光器

李峰 王君涛 殷苏勇 朱小磊*

(中国科学院上海光学精密机械研究所,

上海市全固态激光与应用重点实验室, 上海 201800)

摘要:文章设计了LD 双端面抽运传导冷却复合Nd:YAG晶体电光调Q 激光器,实现脉冲间隔可调的双Q 脉冲输出。用两个光纤耦合输出的LD 模块作为抽运源,BBO 晶体作为Q 开关,在一个泵浦周期内两次启动Q 开关,获得脉冲能量大于14 mJ/脉冲,脉宽 ≤18 ns,脉冲间隔200 μs-230 μs 可调的双Q 脉冲输出,激光器重复频率50Hz ,光-光转换效率达到24%。探索了用KD*P调Q 晶体开关实现稳定双脉冲输出的可行性,通过抑制压电环效应,消除子脉冲现象,最终获得脉冲能量约11mJ/脉冲,脉宽约≤18ns 。

关键字 激光技术;Nd:YAG激光器;双脉冲激光; KD*P调Q ;BBO 调Q 中图分类号:TN248.1 文献标识码 A

Electro-optical Q-switched Double-pulse Laser output Nd:YAG All Solid-State Laser Li Feng Wang Juntao Yin Suyong Zhu Xiaolei*

Shanghai Institute of Optics and Fine Mechanics,Chinese Academy of Sciences, Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques, Shanghai 201800, China

Abstract A LD dual-end pumped, conductively cooled, electro-optical Q-switched composite Nd:YAG laser is designed. Double-pulse laser output with adjustable pulse interval is achieved. By using two fiber-coupled LD modules as the pumping source, BBO crystal as the Q-switch, we acquire double-pulse laser output by opening the Q-switch twice in a pumping cycle time, and the laser is capable of producing two Q-switched 1064nm laser with the single pulse energy more than 14 mJ and pulse width less than 18 ns, the interval between the two pulses is adjustable from 200μs to 230μs at the repetition of 50 Hz, the optical-to-optical efficiency reaches 24%. Furthermore, we explore the feasibility of stable double-pulse laser output by using the Q-switched crystal KD*P, by suppressing the piezoelectric ring effect of KD*P, we

remove the sub-pulse phenomenon and obtain double-pulse laser output with 11 mJ per pulse and pulse width less than 18 ns.

Key words laser technology; Nd:YAG lasers; double-pulse laser; KD*P Q-switch; BBO Q-switch

OCIS codes: 140.3470; 140.3540; 140.3580; 280.1910

作者简介:李峰(1987--),男,硕士研究生,主要从事双脉冲激光器技术研究。E-mail :

导师简介:朱小磊(1966--),男,研究员,博士生导师,主要从事固体激光器技术及激光器应用系统等方面的研究。[email protected]

1 引言

双脉冲全固态激光器在大气环境监测、精细加工、动态全息成像等领域都有较大的应用需求[1~3]。研究表明,采用双激光脉冲打孔技术,在有效提高精细加工效率的同时,又能显著地改善激光打孔的质量[2]。但这种双激光脉冲打孔技术要求将调Q 双脉冲间隔控制在200 ns 以内,否则这种优势将很难体现,这对激光器的双脉冲控制技术提出了很高的要求[4]。此外,在动态全息检测领域,为了实现对快速事件发展过程的连续观察,则要求双脉冲激光输出激光器作为主动成像光源[3]。这种成像技术通常要求的双脉冲激光间隔为1 μs – 1000 μs之间,通过把微秒量级间隔的两个脉冲照明拍摄出来的两个全息图叠置在同一张全息底板上, 可以将被测物体的任何瞬态扰动都显现在双激光脉冲全息图的干涉条纹上,因而获得被测物体的动态信息。

调Q 双脉冲激光器的另外一个重要的应用是作为差分吸收大气探测激光雷达的光发射源或光泵浦源。2003年,美国NASA 研制成功的Ho:Tm:YLF双脉冲激光振荡器[5],利用最大抽运能量为3 J 的半导体激光阵列脉冲泵浦,采用一个泵浦周期两次打开调Q 开关技术实现中红外2.053 μm波长的双脉冲激光输出,直接用于大气探测。该激光振荡器输出两个能量相等调Q 脉冲,每个脉冲能量达到66 mJ。为了进一步提升单脉冲能量,又采用主振荡器功率放大技术,最终获得600 mJ 的调Q 双脉冲激光输出。2005年该课题组报道的Ho:Tm:LuLF晶体

激光器[6],已将调Q 双脉冲激光器输出脉冲能量提升到1 J量级。2008年,在德国研制的差分吸收雷达系统CO 2-IPDA(integrated path differential absorption lidar)系统中 [7]器在10 Hz重复频率下,经过放大器放大后获得最大脉冲能量100 mJ的1064 nm双脉冲输出,脉冲宽度8 ns。

本文研究工作瞄准差分吸收大气探测激光雷达泵浦源的应用需求,设计了电光调Q 双脉冲全固态激光器,比较研究了BBO 与KD*P晶体开关调Q 双脉冲实现的可行性和性能差异。采用BBO 晶体开关实现双脉冲输出,可获得较高的脉冲能量及光-光转换效率。而KD*P晶体开关由于存在严重的压电环效应,极易出现子脉冲现象,对调Q 双脉冲的稳定输出带来严重的负面影响。

2 实验理论分析和实验装置

图1是实验设计的

Nd:YAG激光器原理光路图。出于方便以后种子激光注入锁定应用的考虑,谐振腔设计采用平行平面腔结构,几何腔长约为1100mm ,U 形排布利于结构紧凑稳定。

图1 LD双端泵浦Nd :YAG 双脉冲激光器原理光路图

Fig.1 Schematic of LD dual-end pumped double-pulsed Nd:YAG laser

QWP:quarter wave plate; QS:Q-switch P:polarizer

激光增益介质采用直径为4 mm、双端键合的YAG/Nd:YAG/YAG复合结构晶体棒,晶体总长30 mm,其中掺杂部分长度为20 mm, Nd 3+掺杂浓度为0.5at.%。

采用这种复合晶体结构能有效的减小端面效应及热焦距,在实验允许的最大抽运功率内,由热透镜的焦距公式[8] , 得到晶体的热焦距大于1600 mm 。由铟箔包裹的Nd:YAG晶体紧密夹持在紫铜热沉上,并置于谐振腔中央位置。激光器后腔镜为一平面全反镜,输出耦合镜的初始透过率为60%。根据实验需要,电光调Q 开关分别采用BBO 晶体开关,或KD*P晶体开关。泵浦源采用两个光纤耦合的LD 模块,其最大输出功率为150 W ,中心波长808 nm ,光纤芯径600 μm,数值孔径NA 为0.22。抽运光耦合系统为焦距为1:2.5的双镜系统,耦合效率大于95%,与振荡模体积实现较好的重合。抽运LD 模块的驱动重复频率为50 Hz ,驱动电流占空比约为2.2%,且可调。

根据Magni 理论[9],激光谐振腔中的固体增益介质可以等效成一个焦距随抽运功率动态变化的热透镜。在实验设计的谐振腔结构中,增益介质处于谐振腔中央位置,此时,增益介质处振荡模光斑大小随热透镜焦距值的变化有图2所示的分布规律,显然当热透镜焦距值小于300 mm时,谐振腔将进入非稳区,热透镜焦距值大于300 mm时,振荡模光斑直径的变化非常平缓,有利于输出能量稳定。本文实验过程中,在抽运脉宽420 μs 的条件下,增益介质热焦距远大于300 mm,确保激光器远离非稳定工作区域。

图2 增益介质处振荡模光斑半径随热焦距变化规律

Fig.2 Radius variation of oscillation modes’ spot size with the change of focal length

激光器获得双脉冲输出的机制是合理控制抽运LD 的驱动电脉冲宽度与调Q 开关触发信号时序关系,即在一个抽运周期内,按特定的时序关系,两次开启电光开关,因而获得两个调Q 激光脉冲输出。在相对抽运LD 驱动电脉冲延时一段时间后,Q 开关第一次启动,消耗了增益介质内的反转粒子数,输出Q 脉冲。由于Q 开关的快速关闭,尽管LD 持续抽运,激光器低Q 值状态腔内完全抑制子脉冲的出现,增益介质反转粒子数重新积累,当达到与第一次Q 开关启动时反转值相当时,第二次启动Q 开关并获得调Q 激光脉冲,电驱动同时结束。调Q 双脉冲各自的能量大小及相互之间时间间隔可以通过改变LD 驱动电脉冲宽度及时序关系来主动控制,获得需要的结果。

3 实验结果及分析讨论

在电光晶体开关中,BBO 晶体只有微弱的压电环效应,其工作重复频率可以达到几十kHz 。实验过程中,为了获得稳定的200 μs 间隔双调Q 脉冲,我们首先采用BBO 晶体开关,在LD 泵浦一个周期内,并在接近200 μs 的时间间隔内,使晶体开关两次承受加压-退压过程,以实现双调Q 脉冲的产生。

当抽运LD 的电脉冲宽度为420 μs ,BBO 晶体调Q 高压触发延时分别为220 μs和420 μs时,对应60%的输出耦合率,实验获得了图3所示的双Q 脉冲序列示波照片,从图3(a )上看,前后两个脉冲的峰值基本相同,双脉冲间隔严格受触发信号间隔控制。从图3(b )可以看出,双脉冲的脉冲周期为20 ms,对应重频50 Hz,由于双脉冲间隔200us ,所以在宽X 的时间轴上不能清晰的分辨出双脉冲。改变两个高压触发信号的延时差,就能获得不同时间间隔的调Q 双脉冲输出。而调Q 双脉冲输出能量的大小及相对比值则直接受抽运能量大小的影响,在初始的小泵浦输入条件下,第一个脉冲的能量大于第二个脉冲,随着抽运功率的增大,第二个脉冲能量增大幅度大于第一个脉冲,直到两个脉冲输出能量基本接近。在输入116 mJ抽运光的条件下,获得最大脉冲能量输出大于14 mJ/脉冲。图4为实验测得双调Q 激光器的输入-输出曲线,显示了在特定驱动电流脉冲宽度的条件下,双脉冲能量的变化趋势,在抽运输入能量105 mJ—120 mJ范围内,双脉冲能量基本保持相同。

图3 (a )BBO 调Q 双脉冲图 (b )BBO 调Q 双脉冲周期图

Fig.3 (a )Double pulse laser output using BBO Q-switch

图4双脉冲激光器的输入-输出曲线

Fig.4 Double pulse laser output at different pump energy

当抽运光脉冲的输入能量为108 mJ时,实验对双Q 脉冲的脉冲宽度值进行分别测量,结果见图5。第一个调Q 脉冲示波器显示的脉冲宽度约为18 ns ,第二个调Q 脉冲的脉冲宽度值约为17.5 ns,基本实现了两个脉冲宽度的一致。

(a ) (b )

图5双脉冲的瞬时脉冲波形 (a)第一个脉冲,(b)第二个脉冲

Fig.5 The temporal pulse profile of the double-pulse laser

(a)The first pulse, (b)the second pulse

图6给出该激光器输出平均功率随泵浦输入平均功率的变化曲线,对于T=60%的输出耦合率,当抽运电流脉冲宽度为420 μs时,该双Q 脉冲输出激光器的斜效率达到31%。在最大输出条件下,光-光转换效率接近24%,此时,用Spiricon M 2-200激光光束质量分析仪对激光光束质量M 2值进行测量,测量结果如图7所示,光束在x 轴、y 轴向的M 2值分别为M 22

图6 激光输出功率随抽运功率变化

Fig.6 Q-switched laser power as a function of pump power.

图7 光束质量(M2) 测量图

Fig.7 Measurement of laser beam quality(M2)

实验中,我们用KD*P调Q 晶体开关替代BBO 晶体开关研究双脉冲输出特性,由于KD*P晶体本身存在严重的压电环效应[10,11],原则上不适合200 μs间隔双脉冲输出应用。当抽运能量提高的一定水平时,出现子脉冲输出现象,参见图8, 即在第二次Q 开关打开信号达到之前,已有随机的调Q 子脉冲输出。产生这种现象的原因是实验中当第一个Q 高压完全退压后,由于压电环效应存在,KD*P晶体双折射存在弛豫消退的过程,对于420 μs泵浦脉宽系统,在第一个脉冲输出后的200 μs时间内,KD*P晶体开关处于非完全关闭状态,随着抽运的持续激光器能在第二次高压信号前多次达到阈值,因而输出调Q 子脉冲。

图8 KD*P调Q 输出的子脉冲包络

Fig.8 The pulse train from KD*P Q-switched laser

针对调Q 子脉冲形成的机制,实验中我们通过提高激光器振荡阈值,优化第一个调Q 信号延时时间,并降低泵浦输入能量来抑制200 μs周期内子脉冲的出现,最终在实验上获得了类似图3的无子脉冲的双调Q 脉冲序列稳定输出,最大双脉冲输出能量达到11 mJ/脉冲,调Q 脉冲宽度小于18 ns,激光器光光转换效率达到21.8%。

4 结论

在双端面抽运的传导冷却Nd :YAG 电光调Q 激光器中,插入BBO 晶体开关或KD*P晶体开关,在50 Hz重复频率条件下,采用在一个泵浦周期内两次启动晶体开关高压技术,成功实现了脉冲间隔在200 μs附近可调的调Q 双脉冲输出,前后两个脉冲的能量和脉冲宽度能够保持基本一致。实验结果显示,BBO 晶体开关比KD*P晶体开关更适合在双Q 脉冲输出机制激光器的应用。

文中针对KD*P晶体开关采取的抑制压电环效应引起的子脉冲技术,在相关激光器的研制中具有参考价值。

参考文献

1. G. J. Koch, B. W. Barnes, M. Petros et al..Coherent differential absorption lidar measurements of CO 2 [J].Appl. opt.,2004,43(26): 5092

~5099

2. K. Walther, M. Brajdic, E. W. Kreutz. Enhanced processing speed in laser drilling of stainless steel by spatially and temporally superposed pulsed Nd:YAG laser radiation[J]. The International Journal of Advanced Manufacturing Technology (2008) 35:895~899

3. Li Feng, Ni Xuxiang,Wu Bizhen et al..New method to realize double-pulse laser at high repetition[J]. Acta Photonica Sinica,1998,27(4):342~347 李峰,倪旭翔,吴碧珍等 实现高重复率双脉冲激光器的新方法[J].光子学报,1998,27(4):342~347

4. Wang xueJun,Meng Fanyu,Li Meng et al..Nanosecond dual pulse laser controlling method[J].Chiese J.lasers,2011,38(2):99~102

王学军,孟繁禹,李猛等 纳秒双脉冲激光的控制方法 [J].中国激光 2011,38

(2):99~102

5.Jirong Yu. 600-mJ, double-pulse 2-um laser[J].Opt.Lett.,2003, 28

(7):540~542

6.Songsheng Chen, Jirong Yu, Mulugeta Petros, et al..One-joule double-pulsed Ho:Tm:LuLF master-oscillator-power-amplifier (MOPA)

[C]. OSA/ASSP, February, 6 ,2005,Vienna Austrilia

7.Deutsches Zentrum f ür Luft-und Raumfahrt (DLR) Oberpfaffenhofen. Development of an OPO system at 1.57μm for integrated path DIAL measurement of atmospheric carbon dioxide[J].Appl. Phys.B,2008, 92:295~302

8.Yang Yongming ,Wen Jianguo ,Wang Shiyu et al..Focal length of the thermal lens in LD end-pumped Nd:YAG laser[J].Acta Photonica Sinica, 2005, 34

(12):1769~1772

杨永明,文建国,王石语等,LD 端面泵浦Nd:YAG激光器中的热透镜焦距,光子学报,2005,34(12):1769~1772

9.V.magni, Resonators for solid-state lasers with large-volume fundamental mode and high alignment stability[J]. Appl. Opt., 1986, 25(1):107~117

10.Tang Hao.Study on all-solid state green Laser with high repetition rate of electro-optic Q-switcher[D].Shanghai: Shanghai institution of optics and fine mechanics, 2009

唐昊 全固态高重复率电光调Q 绿光激光器特性研究[D]. 上海:上海光学精密机械研究所 2009

11.M.Roth,M.Tseitlin,N.Angert. Oxide crystals for electro-optic Q-switching of lasers. [J].Glass Physics and Chemistry, 2005, 31 (1): 86~85

实验创新点:

1.

2.

3. 通过一个抽运周期两次打开电光Q 快关,实现了调Q 双脉冲输出,并且实现了了脉冲间隔200 μs 附近可调,通过对泵浦脉宽以及调Q 触发时间的控制,实现了能量近似相等,两个脉冲脉宽近似相等的双脉冲输出。 文章对比分析了BBO 和KD*P调Q 双脉冲的实验差异,并结合两个调Q 晶体的自身差异,给出了分析解释。 KD*P晶体开关存在压电环效应,文章中抑制压电环效应引起的

子脉冲技术,在相关激光器的研制中具有参考价值。


相关内容

  • 新概念激光武器
  • 新概念激光武器 摘要 :本文主要对现下的研究热潮激光武器进行了宏观概述,从激光武器的定 义.分类.优缺点.历史发展.研究趋势.面对的国际问题以及美俄等国研究的 新型激光轻武器的角度对激光武器这种新概念武器进行了简单的介绍. 关键词:激光武器,激光轻武器,暂时性致盲激光武器,非致命激光束武器, 激光防 ...

  • 北工大学激光院研究生学术活动心得报告
  • 北工大学激光院研究生 学术活动心得报告 第三届"学海启航"研究生新生沙龙 本次报告由郑坤(副教授).孙荣毅主持的. 刚刚开始研究生阶段的学习不过一个多月的时间,这将是一个不同于本科阶段的学习历程.面对着学习和科研方面的困惑,校研究生会请来了全国优秀博士论文的获得者.现任北京工业大 ...

  • 2016年中国科技成就
  • 2016年中国科技成就 1.北斗系统.差分仪试验成功将精度从10米提升到1米,配合地基增强系统精度将达到厘米级,并拥有短信功能. 2.2000预警机.全世界最先进,领先美国E-3C预警机接近一代. 3.超级计算机."天河2号"以每秒33.86千万亿次连续第六度称雄. 4.雷达技术 ...

  • 窄线宽光纤激光器的应用
  • 窄线宽光纤激光器的应用 单频光纤激光器具有线宽超窄.频率可调.相干长度超长以及噪声超低等独特性能,借用微波雷达上的FMCW 技术可对超远距离的目标进行超高精度的相干探测,从而会改变市场对光纤传感.激光雷达和激光测距等固有观念,继续把激光器应用革命进行到底. 光库通讯提供的单频光纤激光器拥有世界上独一 ...

  • 焊接方法英文缩写
  • 焊接方法在英文文献中常用的缩写字母 缩写 2W 中方名称 碳弧气割 空气-乙炔焊 电弧硬钎焊 粘接 电弧切割 原子氢焊 电弧氧切割 电弧焊 硬钎焊 热块硬钎焊 裸金属焊条电弧焊 碳弧切割 碳弧焊 空气中碳弧焊 保护气氛中碳弧焊 双碳极电弧焊 挤压焊 二氧化碳气体保护焊 冷焊 冷压焊 浸渍硬钎焊 扩散 ...

  • 现代材料加工方法答案
  • <现代材料加工方法>复习要点 第1章 概述 1.掌握材料的各种分类方法 ① 按化学组成和显微结构分:金属材料.无机非金属材料.有机高分子材料. ② 按性能特征分:结构材料.功能材料. ③ 按用途分:建筑材料.航空材料.电子材料.半导体材料.能源材料.生物材料. ④ 按状态分:固体材料.液 ...

  • 专业焊接工艺方法代号及其符号含义
  • 专业焊接工艺方法代号及其符号含义 江科大焊接最牛逼. 焊接工艺方法代号的符号含义 焊接工艺方法代号 焊接代号 AW--arc welding--电弧焊 AHW--atomic hydrogen welding--原子氢焊 BMAW--bare metal arc welding--无保护金属丝电弧焊 ...

  • 焊接工艺方法代号的符号含义
  • 焊接工艺方法代号的符号含义 焊接工艺方法代号 焊接代号 AW--ARC WELDING--电弧焊 AHW--atomic hydrogen welding--原子氢焊 BMAW--bare metal arc welding--无保护金属丝电弧焊 CAW--carbon arc welding--碳 ...

  • 光电开关原理
  • 光电开关原理 点击次数:1870 发布时间: 2009-3-7 10:24:36 光电开关 的定义:此种产品以光源为介质.应用光电效应,当光源受物体遮蔽或发生反射.辐射和遮光导致受光量变化来检测对象的有无.大小和明暗,而向产生接点和无接点输出信号的开关元件.光电开关包括几种类型,自身不具备光源,利用 ...