消防保卫方案

目 录

一. 工程概况 ······················································································ 2

二. 本工程消防特点 ············································································· 2

三. 消防保卫组织体系及消防器材的配备、消火栓的设置 ···························· 3

四. 消防岗位职责 ················································································ 4

1. 消防领导小组职责 ········································································· 4

2. 消防小组组长职责 ········································································· 4

3. 消防小组副组长职责 ······································································ 4

4. 消防小组成员岗位职责 ··································································· 5

5. 消防负责人岗位职责 ······································································ 5

6. 义务消防队岗位职责 ······································································ 5

7. 义务消防队指挥员职责 ··································································· 5

8. 义务消防队副指挥职责 ··································································· 5

9. 义务消防队员职责 ········································································· 6

五. 消防保卫制度及措施 ······································································· 6

1. 消防保卫制度 ··············································································· 6 2消防保卫措施 ··············································································· 6

六. 消防系统案例运行 ·········································································· 7

七. 消防水泵选择计算 ·········································································· 8

1. 消防给水主管管径的确定································································ 8

2. 水泵的选择 ·················································································· 8

2.1. 消防水泵扬程计算 ···································································· 8

2.2. 水泵选型 ················································································ 8

八. 消防水管布置图 ············································································· 9

九. 施工现场平面布置图及现场消防器材照片 ······································· 9-12

一. 工程概况

工程名称:1号商务办公楼等17项(房山区拱辰街道办事处及长阳镇09-04-21

地块C2商业金融用地项目)6#、7#、8#、9#商务办公楼、S4#商业工

程地下车库

工程地点:北京市房山区拱辰街道办事处良乡高教园区,长虹东路北侧、北京理

工大学南部明理西路南侧、艺林南街西侧

建设单位:北京房开创意港投资有限公司

监理单位:北京时创工程项目管理有限责任公司

设计单位:华通设计顾问工程有限公司

施工单位:北京龙建集团有限公司

建筑层数:6#、7#、8#、9#楼地上15层地下3层;S4商业地上2层、地下3层 建筑面积:58918.14平方米

建筑高度:73.09米

二. 本工程消防特点

1、本工程施工期间跨二个冬季二个雨季。冬季寒冷干燥,风大;夏季炎热;这些都是防火的不利天气,极容易造成火灾,发生危险。

2、本工程主要易燃、可燃的材料为:多层板、脚手板、木方、保温用的草帘子、防水涂料及稀料、油漆、涂料、机械油、氧气、乙炔等生产用品;包装箱、包装袋、棉花被褥、床板、蚊帐、鞋、液化气等生活用品;木桌椅、图版、图纸、文件、复印纸等办公用品。

3、本工程可能引起火灾的火源有:施工现场未熄灭的烟头、焊接火花、防水用的喷灯、氧气、乙炔气割的明火、电线老化过载引起的火花、违章使用切割锯、违反纪律私自使用电褥子、电炉子、电热毯等长期过载运行引起的短路火花。这些都是引起火灾的重要隐患,都是防火需要重点控制的对象。

4、本工程建筑高度73.09m ,现场消火栓配置9套(见施工现场平面图布置、生活区办公区消防器材照片)消防用水量大;施工现场占地面积大,现场材料多、这些都是消防的不利因素。施工现场受条件限制不通畅,但近邻交通干线,交通方便,布局合理,消防器材配备齐全,标志明显、放置方便取用;管理严谨、施

工人员消防意识高,现场警示标志明确,安全员检查细致、要求严格等。这些又是我们的有利因素。

三. 消防保卫组织体系及灭火器配备、消火栓的设置

1、现场成立由项目经理任组长,执行经理和生产经理、技术负责人任副组长的消防保卫领导小组。负责施工现场的消防保卫工作。

2、现场形成由项目部领导小组、防火总负责人、防火区域负责人、义务消防队员组成的消防组织体系。

3、工程项目消防组织机构

组长:牛长连

副组长:张建、陈汉军

组员:侯现生、王生吉、王伟增、王春梅、龚婷婷、彦志辉、汤连涛、刘文生、崔文龙、解召辉、王喜吉、魏志鹏

报警员:张建

现场规划分防火责任区、办公区、生活区、施工区、消防器材置放区、木工棚区、钢筋加工区、工地配电室区、施工区。劳务队人员生活区设在场办公区南侧的专用生活区内。各区设区域防火负责人。

工地成立义务消防队:义务消防队有义务消防队员组成。义务消防队接受消防培训,对发生的火灾实时扑及济组织外源进行灭火。

4、灭火器配备

(1)、办公区3层每层设置灭火器6具、食堂4具。

(2)、生活区三栋三层活动板房每层配备灭火器6具,共计54具,食堂配备灭火器一组4具,配备“五五”配置灭火器材一组。

(3)施工现场每个库房内设置灭火器4具,库房外设置“五五”配置灭火器材一组。

(4)现场总配电室;一级配电箱;二级配电箱分别配备灭火器2具,共计16具。(后期如有增加随时配备相应数量的灭火器)

(5)现场东侧、生活区3#楼首层北边、门卫房西侧分别设置“五五”配置灭火器材一组。

5、消火栓的设置

施工现场消防用水水源来自市政供水由施工现场东侧引入经施工现场消防蓄水罐100mm )。现场共设消火栓五个,现场东侧厕所前设置一个、钢筋加工区设置一个、待定的木工棚处设置一个、配电室西侧设置一个、分包食堂东北角设置一个,每个消防箱内配备水龙带2条,水枪1个。地下工程施工完成后,设置楼层消防竖管及在施楼位置的地面消火栓。

四. 消防岗位职责

1. 消防领导小组职责

1.1制定施工现场防火安全方案和措施,并督促落实。

1.2. 纠正违反消防法规、规章的行为,并向防火负责人报告,提出对违章人员的处理意见。

1.3. 对重大火灾隐患及时提出消除措施建议,填发《火灾隐患通知单》,并报消防监督机关备案。

1.4. 配备、管理消防器材,建立防火档案。

1.5. 组织义务消防队的业务学习和训练。

1.6. 组织扑救火灾,保护火灾现场。

2. 消防小组组长职责

2.1. 组织制定施工现场消防方案和措施。

2.2. 全权管理消防小组和义务消防队。

2.3. 掌握施工现场消防措施落实与消防管理动态,把握事态,按既定目标实施消防工作。

2.4. 落实消防法律、规章制度及施组和方案中的消防工作,对工地消防部署落实。

2.5. 对违反消防法规、规章的人员的处理进行审批。

3. 消防小组副组长职责

3.1. 编写施工现场消防方案和措施,并督促落实。

3.2. 对消防小组及义务消防队进行日常管理。

3.3. 汇集整理火灾隐患,提出消防措施,填发《火灾隐患通知单》。

3.4. 组织布置配备消防器材,并按规划纠违,实施管理。

3.5. 建立防火档案,定期组织防火工作检查,建立防火工作档案。

3.6. 编写小组成员与义务消防队员的消防法律、法规、制度、施组、方案措施的宣传和学习材料,并组织宣传贯彻。

4. 消防小组成员岗位职责

4.1. 学习消防法律、法规、规章、制度、施组中有关消防的内容和消防方案措施。

4.2. 参加施工现场消防方案和措施的制定。

4.3. 纠正违反法规、规章的行为,并向防火负责人及副组长汇报。

4.4. 查处火灾隐患,并报副组长采取措施。

4.5. 检查消防器材的完好情况,查处挪用消防器材及销毁消防器材的行为。

4.6. 督促区域责任人对消防工作进行落实。

5. 消防负责人岗位职责

5.1. 对防火区域内的消防工作进行落实。

5.2. 对防火区域内的易燃、可燃材料实施隔离。

5.3. 对防火区域内的明火作业进行监控,防止火灾发生。

5.4. 对防火区域内的消防违规行为进行制止。

6. 义务消防队岗位职责

6.1. 学习消防法律、法规、规章制度,施工组织设计有关消防工作的内容、消防方案和消防措施。

6.2. 学习火灾扑救知识,进行扑救训练和演习。

6.3. 扑救火灾,保护火灾现场。

7. 义务消防队总指挥员职责

7.1. 组织消防队员学习消防法律,法规、规章制度。

7.2. 组织实施火灾扑救知识,组织扑救训练和演习。

7.3. 组织现场火灾扑救工作,协调各方人员有条不紊,实施扑救和外围救援,组织保护火灾现场。

8. 义务消防队副指挥职责

8.1. 编写义务消防队员消防法律、法规、规章制度、学习材料。

8.2. 编写火灾扑救、火灾训练学习材料和演习策划。

8.3. 协助指挥进行火灾扑救,保护火灾现场。

9. 义务消防队员职责

9.1. 学习消防法律、法规、规章制度。

9.2. 学习火灾扑救知识,参加扑救训练和演习。

9.3. 扑救火灾,保护火灾现场。

五. 消防保卫制度及措施

1. 消防保卫制度

1.1. 现场出入口设置门卫室,昼夜有人值班并佩带标志上岗,同时填写值班记录。

1.2. 现场要有明显的防火标志,消防道路保持畅通。

1.3. 消防设施、工具齐全,严禁私自动用。

1.4. 工程内未经批准不得作仓库,不准住人。

1.5. 现场邻舍必须符合防火规定,库房内易燃性油料和料具不能混放。

1.6. 施工现场动火必须有动火证,使用电热器必须经过行政保管部门批准,电气焊操作人员必须持上岗证,必须遵守电气焊的防火要求。

1.7. 施工现场必须设一名防火负责人,必须有消防机构及责任制,保卫消防检查要有记录及整改措施。

1.8. 氧气瓶、乙炔瓶不准进入建筑物内,两瓶距火不得小于10米。

1.9. 进入现场的各种保温材料必须经过现场保卫部门确认,必须由生产厂家的名称、商标、规格、生产日期及试验报告。

1.10. 严防盗窃、破坏、治安防火发生,一旦发现,应保护好现场并报警。 2消防保卫措施

2.1. 成立施工现场消防保卫领导小组,制定消防预案,严格教育职工遵守各项管理制度。

2.2. 严格遵守消防安全工作标准,贯彻“预防为主,防消结合“的方针,逐级落实消防责任制。

2.3. 设立防火标志牌,防火制度、防火计划在显要位置上墙。施工现场配备充足的消防器材,设置消火栓,并配备足够的消防水带,建立义务消防队,定期进行演习。

2.4. 做好施工现场警卫护场工作,值班人员在值班时要认真负责, 并做好记

录, 不得擅离岗,负责看管建筑材料、机具设备、防止破坏和盗窃,对出入现场人员进行验证。

2.5. 外运的建筑材料和机具,要有材料员开出门证方可放行。

2.6. 施工现场严禁吸烟。

2.7. 施工现场消火栓,消防器材要保持完好状态。布置合理,灵敏有效,使用方便。消防栓3米半径范围内不得堆放任何物品。

2.8. 施工现场动火必须有动火证。

2.9. 氧气瓶、乙炔瓶,要设专用存放处,有安全装置,在操作时,保持两瓶间距5米以上,用后存放原处。焊接时有专人看管和配备消防器材。看火人员在施焊后半小时无火灾隐患后,方可离开焊接现场。

2.10. 不得私自移动或拿用消防器材。

2.11. 施工现场禁止使用易燃物搭设临建,搭设临建要符合防火要求。

2.12. 木工棚内随时清理,木屑、刨花浇水后运出,并配备消防器材。

2.13. 加强现场易燃易爆物品管理,建筑物内不准存放稀料、油漆等易燃品。应设专库存放,配置足够的灭火器材。

六. 消防系统案例运行

施工现场消防安全实行领导主管、岗位负责、分级、分组、分点组织实行,人人参与,人人负责,人人防范。现场救护、外部协助的内外立体交叉的消防救灾的体系运行模式。

1. 火灾救护报警小组主管领导:张鑫国(组长不在时由周凤水行使职责组长)

2. 组长、副组长召集项目义务消防人员,按照事先布置好的各自任务,带相应的工具赶奔现场。

3. 组长、副组长确定消防、灭火方法,传达到个人,立即实行。

4. 义务消防员迅速就近取消防器材赶奔现场。

5. 组长对火灾现场进行人员抢救,疏散。防止次生火灾发生。

6. 火势得不到控制,拨打119火警电话。

7. 疏导员组织疏导现场消防道路。

8. 消防小组、义务消防员保护现场。

七. 消防水泵选择计算

1. 消防给水主管管径的确定

本工程室外消防系统按同时一时间内火灾发生次数为1次, 施工用水量为18M 3/h,消防用水量为36M 3/h,根据计算,消防环管的管径可采用DN100,主楼的立管管径采用DN100。

2. 水泵的选择

水泵的扬程计算公式:H =H1+H2+H3

2.1. 消防水泵扬程计算

H=H1+H2+H3

H 为水泵扬程(m)

H1为水泵吸水口到最不利点高差(m)

H2为管道水头损失(m)。可按H1的10%计算。

H3为最不利用水点出水水压(m)

根据室内消防及生产加压泵流量44M3/h,建筑物高度按73.09(地上部分))=71m 考虑,消防水泵扬程计算如下:

H=H1+H2+H3

H1=71 m

H2=H1*10%=7.1m

H3=6m

H=H1+H2+H3=71+7.1+6=84.1m

施工水泵扬程计算如下;

H =H1+H2+H3

H 1取71m

H2=H1×10%=7.1m

H3=2m

H =H1+H2+H3=71+7.1+2=80.1m

2.2. 水泵选型

根据以上计算,施工水泵扬程80.1m ,消防水泵扬程84.1m 。

消防水泵选用LSG80-250B Q=43.3m3/h H=60m N=15kw型多级离心泵:水

泵主要技术参数如下:

根据以上计算,室内消防及施工用水加压泵的流量Q=36m/h,扬程50.4m 。设计选用立式多级分段式离心泵:50DLX5,该泵转速为2900r /min ,电机功率为5.5 KW,该泵扬程80米。

附图一:现场及生活区消防设施图

附图二、消防设施、水泵、管网布置图

附图三、施工现场消防管线系统图

消防设施平面布置图

消防用水系统图

目 录

一. 工程概况 ······················································································ 2

二. 本工程消防特点 ············································································· 2

三. 消防保卫组织体系及消防器材的配备、消火栓的设置 ···························· 3

四. 消防岗位职责 ················································································ 4

1. 消防领导小组职责 ········································································· 4

2. 消防小组组长职责 ········································································· 4

3. 消防小组副组长职责 ······································································ 4

4. 消防小组成员岗位职责 ··································································· 5

5. 消防负责人岗位职责 ······································································ 5

6. 义务消防队岗位职责 ······································································ 5

7. 义务消防队指挥员职责 ··································································· 5

8. 义务消防队副指挥职责 ··································································· 5

9. 义务消防队员职责 ········································································· 6

五. 消防保卫制度及措施 ······································································· 6

1. 消防保卫制度 ··············································································· 6 2消防保卫措施 ··············································································· 6

六. 消防系统案例运行 ·········································································· 7

七. 消防水泵选择计算 ·········································································· 8

1. 消防给水主管管径的确定································································ 8

2. 水泵的选择 ·················································································· 8

2.1. 消防水泵扬程计算 ···································································· 8

2.2. 水泵选型 ················································································ 8

八. 消防水管布置图 ············································································· 9

九. 施工现场平面布置图及现场消防器材照片 ······································· 9-12

一. 工程概况

工程名称:1号商务办公楼等17项(房山区拱辰街道办事处及长阳镇09-04-21

地块C2商业金融用地项目)6#、7#、8#、9#商务办公楼、S4#商业工

程地下车库

工程地点:北京市房山区拱辰街道办事处良乡高教园区,长虹东路北侧、北京理

工大学南部明理西路南侧、艺林南街西侧

建设单位:北京房开创意港投资有限公司

监理单位:北京时创工程项目管理有限责任公司

设计单位:华通设计顾问工程有限公司

施工单位:北京龙建集团有限公司

建筑层数:6#、7#、8#、9#楼地上15层地下3层;S4商业地上2层、地下3层 建筑面积:58918.14平方米

建筑高度:73.09米

二. 本工程消防特点

1、本工程施工期间跨二个冬季二个雨季。冬季寒冷干燥,风大;夏季炎热;这些都是防火的不利天气,极容易造成火灾,发生危险。

2、本工程主要易燃、可燃的材料为:多层板、脚手板、木方、保温用的草帘子、防水涂料及稀料、油漆、涂料、机械油、氧气、乙炔等生产用品;包装箱、包装袋、棉花被褥、床板、蚊帐、鞋、液化气等生活用品;木桌椅、图版、图纸、文件、复印纸等办公用品。

3、本工程可能引起火灾的火源有:施工现场未熄灭的烟头、焊接火花、防水用的喷灯、氧气、乙炔气割的明火、电线老化过载引起的火花、违章使用切割锯、违反纪律私自使用电褥子、电炉子、电热毯等长期过载运行引起的短路火花。这些都是引起火灾的重要隐患,都是防火需要重点控制的对象。

4、本工程建筑高度73.09m ,现场消火栓配置9套(见施工现场平面图布置、生活区办公区消防器材照片)消防用水量大;施工现场占地面积大,现场材料多、这些都是消防的不利因素。施工现场受条件限制不通畅,但近邻交通干线,交通方便,布局合理,消防器材配备齐全,标志明显、放置方便取用;管理严谨、施

工人员消防意识高,现场警示标志明确,安全员检查细致、要求严格等。这些又是我们的有利因素。

三. 消防保卫组织体系及灭火器配备、消火栓的设置

1、现场成立由项目经理任组长,执行经理和生产经理、技术负责人任副组长的消防保卫领导小组。负责施工现场的消防保卫工作。

2、现场形成由项目部领导小组、防火总负责人、防火区域负责人、义务消防队员组成的消防组织体系。

3、工程项目消防组织机构

组长:牛长连

副组长:张建、陈汉军

组员:侯现生、王生吉、王伟增、王春梅、龚婷婷、彦志辉、汤连涛、刘文生、崔文龙、解召辉、王喜吉、魏志鹏

报警员:张建

现场规划分防火责任区、办公区、生活区、施工区、消防器材置放区、木工棚区、钢筋加工区、工地配电室区、施工区。劳务队人员生活区设在场办公区南侧的专用生活区内。各区设区域防火负责人。

工地成立义务消防队:义务消防队有义务消防队员组成。义务消防队接受消防培训,对发生的火灾实时扑及济组织外源进行灭火。

4、灭火器配备

(1)、办公区3层每层设置灭火器6具、食堂4具。

(2)、生活区三栋三层活动板房每层配备灭火器6具,共计54具,食堂配备灭火器一组4具,配备“五五”配置灭火器材一组。

(3)施工现场每个库房内设置灭火器4具,库房外设置“五五”配置灭火器材一组。

(4)现场总配电室;一级配电箱;二级配电箱分别配备灭火器2具,共计16具。(后期如有增加随时配备相应数量的灭火器)

(5)现场东侧、生活区3#楼首层北边、门卫房西侧分别设置“五五”配置灭火器材一组。

5、消火栓的设置

施工现场消防用水水源来自市政供水由施工现场东侧引入经施工现场消防蓄水罐100mm )。现场共设消火栓五个,现场东侧厕所前设置一个、钢筋加工区设置一个、待定的木工棚处设置一个、配电室西侧设置一个、分包食堂东北角设置一个,每个消防箱内配备水龙带2条,水枪1个。地下工程施工完成后,设置楼层消防竖管及在施楼位置的地面消火栓。

四. 消防岗位职责

1. 消防领导小组职责

1.1制定施工现场防火安全方案和措施,并督促落实。

1.2. 纠正违反消防法规、规章的行为,并向防火负责人报告,提出对违章人员的处理意见。

1.3. 对重大火灾隐患及时提出消除措施建议,填发《火灾隐患通知单》,并报消防监督机关备案。

1.4. 配备、管理消防器材,建立防火档案。

1.5. 组织义务消防队的业务学习和训练。

1.6. 组织扑救火灾,保护火灾现场。

2. 消防小组组长职责

2.1. 组织制定施工现场消防方案和措施。

2.2. 全权管理消防小组和义务消防队。

2.3. 掌握施工现场消防措施落实与消防管理动态,把握事态,按既定目标实施消防工作。

2.4. 落实消防法律、规章制度及施组和方案中的消防工作,对工地消防部署落实。

2.5. 对违反消防法规、规章的人员的处理进行审批。

3. 消防小组副组长职责

3.1. 编写施工现场消防方案和措施,并督促落实。

3.2. 对消防小组及义务消防队进行日常管理。

3.3. 汇集整理火灾隐患,提出消防措施,填发《火灾隐患通知单》。

3.4. 组织布置配备消防器材,并按规划纠违,实施管理。

3.5. 建立防火档案,定期组织防火工作检查,建立防火工作档案。

3.6. 编写小组成员与义务消防队员的消防法律、法规、制度、施组、方案措施的宣传和学习材料,并组织宣传贯彻。

4. 消防小组成员岗位职责

4.1. 学习消防法律、法规、规章、制度、施组中有关消防的内容和消防方案措施。

4.2. 参加施工现场消防方案和措施的制定。

4.3. 纠正违反法规、规章的行为,并向防火负责人及副组长汇报。

4.4. 查处火灾隐患,并报副组长采取措施。

4.5. 检查消防器材的完好情况,查处挪用消防器材及销毁消防器材的行为。

4.6. 督促区域责任人对消防工作进行落实。

5. 消防负责人岗位职责

5.1. 对防火区域内的消防工作进行落实。

5.2. 对防火区域内的易燃、可燃材料实施隔离。

5.3. 对防火区域内的明火作业进行监控,防止火灾发生。

5.4. 对防火区域内的消防违规行为进行制止。

6. 义务消防队岗位职责

6.1. 学习消防法律、法规、规章制度,施工组织设计有关消防工作的内容、消防方案和消防措施。

6.2. 学习火灾扑救知识,进行扑救训练和演习。

6.3. 扑救火灾,保护火灾现场。

7. 义务消防队总指挥员职责

7.1. 组织消防队员学习消防法律,法规、规章制度。

7.2. 组织实施火灾扑救知识,组织扑救训练和演习。

7.3. 组织现场火灾扑救工作,协调各方人员有条不紊,实施扑救和外围救援,组织保护火灾现场。

8. 义务消防队副指挥职责

8.1. 编写义务消防队员消防法律、法规、规章制度、学习材料。

8.2. 编写火灾扑救、火灾训练学习材料和演习策划。

8.3. 协助指挥进行火灾扑救,保护火灾现场。

9. 义务消防队员职责

9.1. 学习消防法律、法规、规章制度。

9.2. 学习火灾扑救知识,参加扑救训练和演习。

9.3. 扑救火灾,保护火灾现场。

五. 消防保卫制度及措施

1. 消防保卫制度

1.1. 现场出入口设置门卫室,昼夜有人值班并佩带标志上岗,同时填写值班记录。

1.2. 现场要有明显的防火标志,消防道路保持畅通。

1.3. 消防设施、工具齐全,严禁私自动用。

1.4. 工程内未经批准不得作仓库,不准住人。

1.5. 现场邻舍必须符合防火规定,库房内易燃性油料和料具不能混放。

1.6. 施工现场动火必须有动火证,使用电热器必须经过行政保管部门批准,电气焊操作人员必须持上岗证,必须遵守电气焊的防火要求。

1.7. 施工现场必须设一名防火负责人,必须有消防机构及责任制,保卫消防检查要有记录及整改措施。

1.8. 氧气瓶、乙炔瓶不准进入建筑物内,两瓶距火不得小于10米。

1.9. 进入现场的各种保温材料必须经过现场保卫部门确认,必须由生产厂家的名称、商标、规格、生产日期及试验报告。

1.10. 严防盗窃、破坏、治安防火发生,一旦发现,应保护好现场并报警。 2消防保卫措施

2.1. 成立施工现场消防保卫领导小组,制定消防预案,严格教育职工遵守各项管理制度。

2.2. 严格遵守消防安全工作标准,贯彻“预防为主,防消结合“的方针,逐级落实消防责任制。

2.3. 设立防火标志牌,防火制度、防火计划在显要位置上墙。施工现场配备充足的消防器材,设置消火栓,并配备足够的消防水带,建立义务消防队,定期进行演习。

2.4. 做好施工现场警卫护场工作,值班人员在值班时要认真负责, 并做好记

录, 不得擅离岗,负责看管建筑材料、机具设备、防止破坏和盗窃,对出入现场人员进行验证。

2.5. 外运的建筑材料和机具,要有材料员开出门证方可放行。

2.6. 施工现场严禁吸烟。

2.7. 施工现场消火栓,消防器材要保持完好状态。布置合理,灵敏有效,使用方便。消防栓3米半径范围内不得堆放任何物品。

2.8. 施工现场动火必须有动火证。

2.9. 氧气瓶、乙炔瓶,要设专用存放处,有安全装置,在操作时,保持两瓶间距5米以上,用后存放原处。焊接时有专人看管和配备消防器材。看火人员在施焊后半小时无火灾隐患后,方可离开焊接现场。

2.10. 不得私自移动或拿用消防器材。

2.11. 施工现场禁止使用易燃物搭设临建,搭设临建要符合防火要求。

2.12. 木工棚内随时清理,木屑、刨花浇水后运出,并配备消防器材。

2.13. 加强现场易燃易爆物品管理,建筑物内不准存放稀料、油漆等易燃品。应设专库存放,配置足够的灭火器材。

六. 消防系统案例运行

施工现场消防安全实行领导主管、岗位负责、分级、分组、分点组织实行,人人参与,人人负责,人人防范。现场救护、外部协助的内外立体交叉的消防救灾的体系运行模式。

1. 火灾救护报警小组主管领导:张鑫国(组长不在时由周凤水行使职责组长)

2. 组长、副组长召集项目义务消防人员,按照事先布置好的各自任务,带相应的工具赶奔现场。

3. 组长、副组长确定消防、灭火方法,传达到个人,立即实行。

4. 义务消防员迅速就近取消防器材赶奔现场。

5. 组长对火灾现场进行人员抢救,疏散。防止次生火灾发生。

6. 火势得不到控制,拨打119火警电话。

7. 疏导员组织疏导现场消防道路。

8. 消防小组、义务消防员保护现场。

七. 消防水泵选择计算

1. 消防给水主管管径的确定

本工程室外消防系统按同时一时间内火灾发生次数为1次, 施工用水量为18M 3/h,消防用水量为36M 3/h,根据计算,消防环管的管径可采用DN100,主楼的立管管径采用DN100。

2. 水泵的选择

水泵的扬程计算公式:H =H1+H2+H3

2.1. 消防水泵扬程计算

H=H1+H2+H3

H 为水泵扬程(m)

H1为水泵吸水口到最不利点高差(m)

H2为管道水头损失(m)。可按H1的10%计算。

H3为最不利用水点出水水压(m)

根据室内消防及生产加压泵流量44M3/h,建筑物高度按73.09(地上部分))=71m 考虑,消防水泵扬程计算如下:

H=H1+H2+H3

H1=71 m

H2=H1*10%=7.1m

H3=6m

H=H1+H2+H3=71+7.1+6=84.1m

施工水泵扬程计算如下;

H =H1+H2+H3

H 1取71m

H2=H1×10%=7.1m

H3=2m

H =H1+H2+H3=71+7.1+2=80.1m

2.2. 水泵选型

根据以上计算,施工水泵扬程80.1m ,消防水泵扬程84.1m 。

消防水泵选用LSG80-250B Q=43.3m3/h H=60m N=15kw型多级离心泵:水

泵主要技术参数如下:

根据以上计算,室内消防及施工用水加压泵的流量Q=36m/h,扬程50.4m 。设计选用立式多级分段式离心泵:50DLX5,该泵转速为2900r /min ,电机功率为5.5 KW,该泵扬程80米。

附图一:现场及生活区消防设施图

附图二、消防设施、水泵、管网布置图

附图三、施工现场消防管线系统图

消防设施平面布置图

消防用水系统图


相关内容

  • 2012年街道办消防安保百日大会战实施方案
  • 各社区.辖区各有关单位: 根据江干区防火安全委员会<关于开展江干区消防安全保卫"百日大会战"活动实施方案>的要求,为确保党的"x大"召开期间消防安全保卫工作,有效遏制重特大火灾和群死群伤火灾事故的发生,切实加强和全力维护社会稳定工作,经街道领导研究 ...

  • 施工现场临时消防施工专项方案
  • 观山苑(昆明市雨花片区KCC2011-84号地块城市棚 户区改造项目) 施工现场临时消防施工方案 编制人: 审核人: 批准人: 山河建设集团有限公司 日期:年 月 日 目 录 一.工程概况 .................................................... 4 ...

  • "平安国庆"专项行动消防宣传实施方案
  • 为贯彻部消防局"全国公安消防部队奋战50天全力做好新中国成立x 周年消防安全保卫工作电视电话会议"和我局"奋战50天全力做好新中国成立x 周年消防安全保卫工作誓师大会"的精神,广泛掀起迎国庆消防宣传热潮,有效提高市民的消防安全意识和素质,展示公安消防部队的良好 ...

  • 郯城县第一人民医院安全生产工作方案
  • 郯城县第一人民医院安全生产工作方案 为认真做好我院安全生产.安全保卫及消防安全工作,及时消除事故隐患,确保本院职工.就诊病人及家属的人身安全,保证医院公共财产完好无损,特制定以下工作方案. 一.指导思想 坚持"安全第一,预防为主"的基本方针,相关部门和科室密切配合,强化安全生产. ...

  • 五大责任书
  • 工程质量目标管理责任书 甲方:浙江长荣建设工程有限公司 (以下简称甲方) 乙方:绍兴文理学院元培学院易地新建工程(学生公寓A1楼.B1楼.A2A3楼. B2B3楼) (以下简称乙方) 为了认真贯彻执行建设工程质量法律.法规及有关标准.规范.规定,加强分公司工程质量管理,提高施工现场质量管理水平,确保 ...

  • "迎国庆.保安全.促和谐"消防安全保卫专项行动实施方案
  • 民勤消防大队按照公安部消防局和总队<"迎国庆.保安全.促和谐"消防安全保卫专项行动实施方案>的总体要求,迅速召开专门会议进行动员部署,并结合辖区内实际,制定了<民勤县"迎国庆保安全促和谐"火灾隐患排查整治专项行动方案>和<民勤县& ...

  • 安全保卫工作预案
  • 一、指导思想、工作原则、重点和任务目标 以“三个代表”重要思想为指导,在自治区党委、自治区人民政府的领导下,根据博览会广西领导小组的部署,坚持“安全第一,内紧外松,形式缓和,文明执勤”的指导思想,正确处理安全与便利的关系,安全与便利相结合,既确保博览会的安全,也为参会客商、群众提供便利。工作原则是: ...

  • 安全保卫工作职责
  • 第二届中国—东盟博览会(含中国—东盟博览会、中国—东盟商务与投资峰会、南宁国际民歌艺术节等大型活动,以下简称“博览会”)将于20xx年10月在我区首府南宁市举行。为确保第二届博览会安全顺利举行,根据第二届博览会的情况,制定本方案。 一、指导思想、工作原则、重点和任务目标 以“三个代表”重要思想为指导 ...

  • 消防安全保卫工作总结
  • 浔阳区地处九江市城区中心,辖区各类重点单位、场所较多,其中大多数为宾馆、饭店、商尝市尝集贸市场以及歌舞娱乐场所等人员集中场所,一旦发生火灾,极易造成重大财产损失和重大人员伤亡事故。为确保国庆期间浔阳城区人民群众生命财产安全,防止重、特大火灾事故发生,结合认真贯彻落实“9.22”公安部防止重、特大火灾 ...