锅炉砌筑施工方案

目 录

1、目的 ........................................................................................................................................................................... 3

2、适用范围 ................................................................................................................................................................... 3

3、编制依据 ................................................................................................................................................................... 3

4、作业项目概述 ........................................................................................................................................................... 3

5、作业准备 ................................................................................................................................................................... 3

5.1施工组织机构 ................................................................................................................................................... 3

5.2施工人员配置 .................................................................................................................................................. 4

5.3机械设备配置 .................................................................................................................................................. 4

6、作业条件 ................................................................................................................................................................... 5

6.1施工工期 ........................................................................................................................................................... 5

6.2相关条件 ........................................................................................................................................................... 5

6.3材料管理 ........................................................................................................................................................... 6

6.4材料堆放 ........................................................................................................................................................... 6

7作业顺序 ...................................................................................................................................................................... 6

7.1施工流程 ........................................................................................................................................................... 6

7.2施工进度计划(见附表) ............................................................................................................................... 6

8、作业方法 ................................................................................................................................................................... 6

8.1点火风道(含预燃室) ................................................................................................................................... 6

8.2水冷风室 .......................................................................................................................................................... 8

8.3炉膛(包括密相区,布风板) ...................................................................................................................... 8

8.4水冷屏、过热屏 .............................................................................................................................................. 9

8.5旋风分离器 ...................................................................................................................................................... 9

8.6返料器及返灰通道 ........................................................................................................................................ 10

8.7水平烟道 ........................................................................................................................................................ 10

8.8省煤器炉墙 .................................................................................................................................................... 11

9、耐火、保温混凝土施工技术要求 ......................................................................................................................... 11

9.1施工前的准备工作 ......................................................................................................................................... 11

9.2耐火混凝土搅拌的要求 ................................................................................................................................. 11

9.3成型 ................................................................................................................................................................. 11

9.4浇筑料的养护 ................................................................................................................................................. 12

9.5框架式耐火混凝土炉墙的施工要求 ............................................................................................................. 12

9.6试块 ................................................................................................................................................................. 12

10、材料的性能要求 ................................................................................................................................................... 13

11、模型制作安装技术要求 ....................................................................................................................................... 17

11.1模型选材制作 ............................................................................................................................................... 17

11.2模型储存 ....................................................................................................................................................... 17

11.3支模 ............................................................................................................................................................... 17

12、验收标准及质量检验控制 ................................................................................................................................... 18

12.1施工质量验收标准 ....................................................................................................................................... 18

12.2验收方法 ....................................................................................................................................................... 18

13、安全文明施工及环境保护 ................................................................................................................................... 19

13.1工程安全、健康、环境管理 ....................................................................................................................... 19

13.2安全管理工作方针 ....................................................................................................................................... 19

13.3建立工地安全保证体系 ............................................................................................................................... 19

13.4安全技术保证措施 ....................................................................................................................................... 20

13.5施工现场环境保护措施 ............................................................................................................................... 20

13.6文明施工管理 ............................................................................................................................................... 20

14、职业健康安全危险源辨识及预防控制 ............................................................................................................... 22

1、目的

编制本作业指导书的目的是为了本专业施工人员更具体的了解工程的施工技术要求,并进行技术和资源的准备工作,同时也为了施工进程的顺利开展和现场的合理布置,尽量发挥我公司的优势,合理的组织施工,科学的进行管理,努力采用新技术,有效的利用人力、物力、安排空间和时间组织安全文明施工,注意保护环境,以及实现安全、优质、准点、文明、低耗,取得更大的技术经济效果。

2、适用范围

××集团自备电厂安装2台YG-600/9.8-M型自然循环流化床锅炉炉墙砌筑工程。

3、编制依据

3.1部颁《电力建设施工及验收技术规范》(锅炉机组篇)DL/T5047-95

3.2《工业炉砌筑工程施工及验收技术规范》(GBJ211-87)

3.3《电力建设安全工作规程》(DL50091-92)

3.4我公司的企业标准QB/LA10100-2000质量手册及相关程序文件。

3.5济南锅炉厂提供的砌砖图

3.6设计院提供的《设计说明书》

4、作业项目概述

4.1本类型锅炉是由济南锅炉厂设计制造的YG-600/9.8-M型自然循环流化床锅炉。是一种高效低污染新型155MW 燃煤燃烧设备, 锅炉炉墙分为:热烟发生器(预燃室)、点火风道、水冷风室、炉膛燃烧室、炉膛出口(含屏过)、旋风分离器入口烟道、旋风分离器、返料器、旋风分离器出口烟道、平衡烟道及尾部对流烟道等部分。该类型锅炉炉型为:高温高压自然循环燃烧方式,平衡通风、露天布置、固态排渣、其内衬耐火(耐磨)、保温材料。安装工程量较大(大约1600T ),而且交叉部位多,与同类炉相比有许多特殊之处,炉墙的砌筑是非常关键的工序并有其特殊要求,必须保证炉墙的严密性和确保炉墙长期经受高温、振动,确保锅炉长期安全、正常运行。

4.2 工艺流程

被破碎筛分后的煤和起脱硫作用的石灰石,经料仓和输送设备送至燃烧室,在一、二次风的作用下产生流化沸腾燃烧,高温的烟气以5m/s速度裹着不断输进的固体颗粒沿炉膛上升。所产生的热量以辐射的形式传递到冷壁管上,然后继续上升由炉膛出口以25m/s的速度进入旋风分离器,燃烧后的烟气经旋风分离后,未燃尽颗粒通过返料器,在高压返料风的作用下返回燃烧室循环燃烧,已燃尽的微颗粒在高温烟气的作用下经过平衡烟道进入尾部烟道,通过高、低温过热器、省煤器、空气预热器、电除尘、最后在引风机的作用下经过烟囱排放到大气中。

5、作业准备

5.1施工组织机构

5.2施工人员配置

针对该筑炉工程,须组织有丰富安装经验的管理人员和工人进驻现场,以最优秀的施工质量,最科学的工艺和最短的工期,安全文明的完成施工任务。

5.3机械设备配置

施工机具设备配置是否合理和完善,将直接影响施工进度和施工质量,本工程必须投入性能最佳匹配完善的施工机具,以确保施工工期和施工质量。

6、作业条件

6.1施工工期

以水压试验完成并验收合格,具备施工条件之日计算,每台炉全部内衬材料安装,绝对施工工期60天(水压试验前完成非承压结构件内衬材料的80%工程量)。

6.2相关条件

6.2.1施工前应具备“三通一平”,即施工用电接到锅炉零米层,施工合格水接到锅炉零米层,运料道路畅通,施工现场堆料场地平整,排水畅通,具备堆放材料,运输车能到场地卸车,场区面积大约350㎡左右。

6.2.2施工现场应提供拌料场地和木模预制场地,为了保证浇注料的施工质量,拌料场地应靠近锅炉,以缩短运料时间。

6.2.3在交付给内衬料施工时,原则上应具备以下条件;

6.2.3.1炉膛(水压实验后)

一次、二次风管、给料管、仪表套管、排渣管即返气管、人孔门框都已安装完毕,炉膛鳍片拼接焊缝全部焊接结束,锅炉管拼接处及局部脱落的销钉补焊完,焊瘤打磨光滑,布风板风嘴安装完毕. (可以在全部施工完后 ,拆除脚手架并清理干净再安装风嘴,防止砸坏风嘴,最后施工布风板浇注料。)

6.2.3.2回料系统

按锅炉厂设计要求及通过安装程序,回料阀仪表开孔(含套管)以及高压风管全部安装完毕,布风嘴安装结束,人孔门框安装就位,设备已安装验收。

6.2.3.3旋风分离器

已安装就位,所有的拼接焊缝满焊完,人孔已安装好,仪表开孔或套管安装完,安装临时的支撑金属焊接件已撤除,炉膛出口与分离器进口间的膨胀节已安装定位。

6.2.3.4平衡烟道

已吊装就位,所有的拼接焊缝符合要求,平衡烟道与高过连接的出口三维膨胀节的安装尺寸已定位。

6.2.3.5外部条件

所有的人孔外走道钢架及平台扶梯和栏杆安装完毕,具备安全的运料砌筑条件。

6.3材料管理

6.3.1材料进场及领用

6.3.2根据施工进度计划的安排,排出材料进场计划,按照计划发运材料。

6.3.3材料到场后,首先检查有无出场合格证和质保书,证件齐全,材料名称核对正确后再登记入库或堆放到指定位置。

6.3.4使用材料时,必须由专人负责领用,以免弄错或用错材料,造成运行的使用质量隐患。

6.3.5每天应建立材料使用及库存数量记录,提供给发货计划人,协调材料发货和运输安排。

6.4材料堆放

6.4.1堆放材料分门别类摆放至指定位置,并挂上表示牌,注明材料种类、数量、批号。

6.4.2成品、半成品分开堆放,并挂标识牌。

6.4.3预制好的施工模板分类摆放,挂上标识牌,注明各种参数和使用部位,以利施工时使用和不会错用。

6.4.4做好标识管理资料,以便进行材料数量和品种的帐目校对,以及各使用部位的材料数量统计。

7作业顺序

7.1施工流程

施工准备→预燃室(点火器)→点火风道→一次风道→水冷风室→返灰通道→返料器→料腿→旋风分离器锥体→旋风分离器直筒→旋风顶→炉膛密相区→水冷屏→过热屏→出烟屏→分离器入口→分离器出口→水平烟道→省煤器炉墙→门类炉墙→竣工清理

7.2施工进度计划(见附表)

8、作业方法

循环硫化床工况表明,炉墙砌筑工程非常关键,施工质量直接关系到炉墙的严密性、抗热振稳定性、抗磨损和保温隔热性能。因此施工工艺必须科学、严谨才能对施工过程进行严格的质量控制,以确保锅炉安全、有效、长寿运行。

8.1点火风道(含预燃室)

每台锅炉设计有4个点火风道,在风室后墙左右对称布置。点火风道耐火材料施工因其外

形为圆筒型,施工工艺较复杂,且点火工作温度最高(点火预燃室1300℃-1500℃, 点火风道900℃-1200℃),并且由于根部风和周围风压调节匹配及油枪给油压力和雾化较果的问题,极容易造成柴油积聚爆燃和附着燃烧,造成局部超高温。点火风道在点火时处于热振及高温状态,耐火材料的选择,施工方法的优劣,将直接影响施工质量。

8.1.1预燃室:浇注抗热振浇注料(≈3.74m ³) ,浇注厚度δ=50mm, 成型尺寸φ=1300mm ,筒内设置靶钉,无需焊接钩钉及网格绑扎,此项工作建议地面施工(如安装后施工困难,施工质量难以保证),养护期后再进行安装。每台预燃室风冷夹套上设计有30个风口,耐火材料施工时,风口处要圆滑过渡,并做好密封,防止耐火材料进入风冷夹套内。施工后要对每个风口检查、清理确保畅通。预燃室中沿筒体方向均匀布置10道膨胀缝,并与其垂直布置了5道环形膨胀缝,施工时,采用五合板或木制板制成“z ”型预埋浇注材料中,待烘炉后自然形成一道δ=5mm 的膨胀缝。

注意事项:

①此部位施工前金属靶钉表面涂刷沥青δ=2mm ,耐热销钉可不涂沥青。

②耐火材料要有较高的抗热振稳定性,且不易脱落。

③支模尺寸准确,形状、角度符合设计,要求模板平整无孔洞,无台阶,易脱模,支撑要求牢固,严禁跑模现象出现,支撑方木不小于400mm ×60mm 。

8.1.2点火风道、一次风道

点火风道内壁设置“Y ”型抓钉,每个抓钉长度为225mm ,埋人浇注材料部分预涂刷二道沥青δ=2mm ,以保证热态时抓钉可以自由膨胀,总厚度设计为δ=250mm 。保温层采用4a 号硅酸铝棉毡(≈38 m³,含一次风道),δ=180mm ,浇注抗热震浇注料(≈13.5 m³,含一次风道),浇注厚度δ=70mm ,成型尺寸Φ=2000mm ,风筒中有10道环形膨胀缝,与这些膨胀缝垂直的膨胀缝间距是600mm ,采用五合板或木制板制成“Z ”型预埋浇注料中,待烘炉后就自然形成5mm 的膨胀缝,因其设计为圆形如果安装后施工,顶部工作比较困难,施工质量难保证,建议此项工作再地面施工,养护期后再进行安装。

注意事项:①注意预留安装间隙。

②施工浇注料前,硅酸铝棉毡表面应喷涂防水成膜材料防止浇注水分损失。

③必须保证“Y ”型抓钉至向火面浇注料保护层≥25mm 。

④模具尺寸要准确,符合设计,要求模板无孔洞,无台阶,易脱模,支撑要求牢固,

严禁跑模,两侧可以对称施工,增加斜拉 ,构成三角形稳定结构。

8.1.3一次风道施工工艺与点火风道相同,其成型尺寸:Φ=1900mm.

注意事项:

一次风道与点火风道相交处,耐火材料膨胀应力方向发生了改变,两个方向集中到一起,易使材料脱落。采取措施:①拐角处不留膨胀缝。两侧膨胀距拐角为300mm 。②加密焊接“U ”

型销钉,(或绑扎钢筋网络)间距为150mm ,防止耐火材料起拱、脱落。

8.2水冷风室

8.2.1水冷风室是炉膛和点火风道的媒体,承担着火焰输送任务,工作温度850℃~900℃,风速>20m/s,炉墙耐火材料为抗热震浇注料(≈15M ³)侧面与底部和顶部均为δ=70mm.

8.2.1.1水冷风室底部为震捣抹平无需支模,侧墙需支模浇注,施工时下层模浇注完毕后就位上层模板, 并与下层模板连接为一整体, 上层模板浇注完毕后拆除下层模板,即倒模施工,浇注料施工时,材料搅拌均匀(按材料厂家配比说明严格控制)将搅拌好的材料用容器运至现场注入模具内,震捣时间和施工方法,严格按浇注料施工技术要求施工。

8.2.1.2水冷风室顶部浇注困难极大,并有风帽、管孔。建议耐磨材料为锆莫来石可塑料,浇注厚度δ=70mm (≈4.78M ³)此处施工有两种方法:①安装后施工,要求填塞密实,施工不宜过宽,一般为100~200的模板,可塑料由模板和管排之间一点一点填塞,施工时下方敷一层塑料布,并将失落的可塑料及时回收利用。②安装前施工,即地面施工,将水冷风室顶倒置,无需支模振捣抹平即可。养护期后再进行安装。(注意预留安装间隙)

8.2.3注意事项:

①浇注料施工前销钉上和布风板风帽预先涂刷二道沥青漆δ=2mm 。

②销钉至向火面方向,浇注料保护层≥25mm 。

③风室后墙与点火风道相交处施工工艺见1.3一次风道施工注意事项。

8.2.4模具制安:

支模尺寸应准确,形状、角度符合设计要求,模板平整无孔洞、无台阶 ,制作好的模板上在固定前刷上脱模剂,以便脱模时不损坏施工表面,在固定模板时高度不宜过高,应根据施工条件而定,以方便浇捣为宜,制好的模板应能承受一定的撑力,使其在浇注时不变形。

8.3炉膛(包括密相区,布风板)

8.3.1CFB 锅炉在运行中,炉膛内部气、固两相流的工况极为复杂,大量的回混物料严重冲蚀着四周炉墙,密向区炉墙有两个人孔,四个启动燃烧器孔,两个返料入口,六个给煤口和二十四个二次风入口及多个测温测压孔,这些结合部位属于重磨损区,由于膨胀应力发生了方向改变,两个方向集中到结合处易出现材料脱落损伤蒸气管,施工中应重点控制。四侧水冷壁防磨区与水冷壁的过渡区域,此区域磨损是由沿壁下行的物料冲刷造成,此处要求必须按图施工,留出相同的倒角以破除涡流,从而减少沿壁面下行的物料流冲刷。

8.3.2此处施工经水压试验合格及截止线处金属喷涂后进行。因炉膛内烟气流速5.2m/s,温度850℃~900℃,炉墙耐火材料选用钢纤维自流式耐磨浇注料。截至线至拐点区域浇注厚度δ=73mm ,其它部位浇注厚度δ=70mm ,密向区四面墙均设有垂直膨胀缝,其深度和宽度要满足耐火材料的膨胀要求,在支模板时将两层五合板或木制板预埋浇注料中,其缝中的硅酸铝(或石棉绳)可在烘炉后填塞,填塞时可涂抹高温胶泥并将硅酸铝耐火纤维填平捣实。

8.3.3各孔洞处施工:为了防止各孔洞结合部位浇注料脱落,在孔洞周围300mm 范围内增加100mm ×100mm Φ6钢筋网格,材质为1Cr25Ni20Si2, 将耐热钢筋网格一端与水冷壁扁钢锚固,另一端与Y 型销钉及外护板锚固,并涂δ=2mm 沥青。截至线处齿带结构及四角倒三角斜坡处施工,结合部位要圆滑过渡。

8.3.4布风板上设计由内嵌风帽2351只和5个放渣管,风帽埋于浇注料部分先用δ=2mm 硅棉垫包覆,有利于其膨胀及检修时更换。风帽上的小孔在浇注前用塑料带封好,防止浇注料堵塞,施工后对每个风口检查、清理、确保畅通。此处设计硅澡土保温混凝±δ=80mm ,自流式耐磨浇注料δ=70mm 。

8.3.5注意事项:

①二次风喷嘴、给煤喷嘴,耐热钢筋网格及靶钉等埋入浇注料中的所有铁件在浇注前均涂刷沥青漆δ=2mm 。

②耐热钢筋网焊接锚固及靶钉补焊时,应用材质与其相适应的焊条。

③钢筋网格及靶钉至向火面浇注料保护层≥25mm.

8.4水冷屏、过热屏

8.4.1水冷屏、过热屏、出烟屏工作温度约900℃,烟气表观速度6m/s。浇注自流式耐磨浇注料(或耐磨可塑料)δ=70mm ,炉膛内垂直布置的水冷屏与过热器底部浇注料由于膨胀应力容易造成脱落,应增加耐热钢筋材质为1Cr25Ni20Si2。做成“U ”型网格,间距为100mm ,用相应材质的焊条焊接在靶钉上,防止耐火材料脱落,“U ”型钢筋网至向火面浇注料保护层≥25mm 。

8.4.2注意事项:

①穿顶穿墙处部件包裹3mm 硅棉垫。

②靶钉及耐热钢筋表面涂沥青漆二道。

③金属喷涂应在浇注前完成。

④所有施工面要密实,杜绝孔洞,确保施工质量,操作方法见2.1.1。

8.5旋风分离器

8.5.1整台锅炉有2个旋风分离器入口烟道,后墙左右对称布置,烟气通过这里携带物料颗粒流入旋风分离器,流速急剧增加(由6m/s增至26m/s)工作温度850℃~900℃,烟气颗粒浓度达150kg/Nm3. 对炉墙磨损较为严重。埋管区炉墙四周增加Φ6耐热钢筋网格150mm ×150mm (1Cr25Ni20Si2)浇注料保护层≥25mm ,三维膨胀处炉墙沿方环设置的膨胀缝宽度为80mm ,用于吸收炉膛与分离器之间的相对膨胀量,曲折膨胀缝,可防夹灰并增加气密性。

8.5.2旋风分离器炉墙结构总厚度δ=360mm ,微孔硅酸钙保温砖δ=200mm ,硅酸铝毡δ=70mm ,旋风入口直段炉墙,旋风顶炉墙及旋风出口炉墙耐火材料为钢玉耐磨浇注料δ=90mm ,旋风锥体及料腿耐火材料为普通耐磨浇注料δ=90mm 。

8.5.3微孔硅酸钙异型砖砌筑:由于“Y ”行抓钉安装焊接使此项的砌筑工作困难较大。砖槽的

尺寸与抓钉的尺寸(300mm ×300mm )不象理论设计那样十分准确,砌筑可以和焊接抓钉同时施工,保温砖砌筑灰缝不大于5mm, 且灰缝均匀饱满, 在砌筑不方便的部位, 应用保温混凝土填实。施工工艺应严格按耐火材料厂家提供的工艺标准执行,保证施工质量。

8.5.5浇注料施工难度较大,模具制作困难,膨胀缝设置复杂,每块膨胀体相互咬合,相互牵压,施工时以分隔块进行,并跳跃施工(即先浇1.3.5再浇2.4.6一次类推),曲折施工缝,侧面粘5mm 硅酸铝纤维毡。模板要承受炉墙本身的推力和施工振捣时传递到模板上的力及其外部因素,因此模板要有足够的强度,支设必须牢固,尺寸准确,其支设方法根据现场具体情况定。 注意事项:

①“Y ”行抓钉,耐热钢筋网等埋入浇注料部分先涂刷沥青δ=2mm 。

②“Y ”型抓钉焊接要牢固,分叉钉端至浇注料表面保护层≥25mm 。

8.6返料器及返灰通道

8.6.1除接点处,各区域典型衬层结构为:总厚度360mm ,刚玉耐磨浇注料δ=90mm ,硅酸铝毡δ=70mm ,微孔硅酸钙制品δ=200mm ,所有浇注区用“Y ”型抓钉固定。

8.6.2由分离器分离下来的物料,通过料腿进入返料器,工作温度约950℃,烟速1-2m/s,灰料浓度高达3500kg/Nm³。成形尺寸为Φ1500mm, 此部位设计结构复杂,作业空间狭窄。施工难度大,不容易进行质量控制,并且属于重磨损区,振动较大,易使材料相互挤兑、销钉炭化造成脱落,影响返料,是最容易出现质量问题的部位,施工中应重点控制施工质量。

8.6.3注意事项:

①施工浇注前硅酸铝毡表面应喷涂防水成膜材料防止浇注水分损失。

②金属支撑件表面应涂沥青δ=2mm 。

③浇注施工以分隔块进行,曲折施工缝,侧面贴硅酸铝毡。

④阀体过桥处浇注料应加钢纤维,并设置止裂圆槽,利于消除过桥应力。

⑤返灰通道与炉膛结合部位的耐热钢筋网焊接要牢固。

⑥导灰管和顺灰管之间的硅酸铝毡在安装前填实。

8.7水平烟道

由旋风分离器流出的烟气颗粒浓度很小约60kg/ Nm³, 对炉墙材料构成磨损较轻,工作温度700℃-900℃,烟气流速约28m/s。顶棚过热器包墙布满靶钉,总厚度为270mm ,浇注自流式耐磨材料δ=70mm (或可塑料)顶棚上180mm 硅酸铝毡保温20mm 抹面料。12根Φ159包覆管为50mm 自流式耐磨浇注料。其余各区域结构是典型的板式炉墙结构,总厚度360mm ,90mm 普通耐磨浇注料、70mm 硅酸铝毡、200mm 微孔硅酸钙保温砖。除顶棚处,所有浇注区用“Y ”型抓钉固定。 注意事项:

①施工浇注料前,硅酸铝毡表面喷涂防水成膜材料,防止浇注水分损失。

②金属支撑件表面应涂沥青漆二道。

③12跟包覆管浇注料中增加耐热钢筋网格120mm ×120mm (1Cr25Ni20Si2) ④浇注施工以分隔块进行, 并跳跃施工, 曲折施工缝, 侧面贴硅酸铝毡. 8.8省煤器炉墙

携带粒子烟气流经该处逐渐减小约12m/s,灰颗粒浓度很小约60kg/Nm³, 工作温度600-700℃之间。对材料磨损较轻。炉墙总厚度220mm. 90mm 矾土水泥耐火混凝土,130mm 微气硅酸钙保温砖,所有浇注区用“Y ”型抓钉固定。 注意事项

①金属支撑件表面应涂沥青油漆二道。

②浇注施工以分隔进行并跳跃施工,曲折施工缝,侧面贴硅酸铝毡。 9、耐火、保温混凝土施工技术要求 9.1施工前的准备工作

9.1.1浇筑料在运抵现场时,应确保搅拌前干燥、无结块现象,暂时不用的料应储存在干燥、防潮和防火的地方。

9.1.2需要支设模具的地方,严格按照规定尺寸做好并将其固定牢固。

9.1.3施工部位清理干净,内壁不得黏附杂物,预埋金属件(锚固件)浇筑金属面在浇筑前涂2毫米沥青漆。

9.1.4采用强制式搅拌机并选用高频振动棒振动成型。 9.2耐火混凝土搅拌的要求

9.2.1宜采用强制式搅拌机按规定的时间搅拌均匀,严禁混入任何杂物。同时根据现场施工实际需要,安排其它施工机械、器具如小磅秤、加水桶、插入式或平板式振动器等。

9.2.2耐火混凝土应按施工配合比进行配制,加液量应根据施工配合比和现场的温度、湿度及湿料的运输距离确定,不得随意增减,如超出加液量范围应及时通知厂家现场处理。

9.2.3每次搅拌量不宜太多,搅拌好的湿料应在规定的时间用完,超过凝结时间的湿料,严禁二次加液使用。

9.2.4掺入钢纤维时,应将钢纤维均匀撒入干混合料内,搅拌时间不小于1min 。加水搅拌后的湿料中,钢纤维应分布均匀,不得有成团现象。

9.2.5不同种类不定型浇注料所用搅拌机严禁混合使用,尽量做到一种浇注料,一个搅拌机;换料时要求把搅拌机刷净凉干。 9.3成型

9.3.1对于多孔吸水表面,施工前应充分用水喷湿,及采取特殊防吸水措施,以防止浇筑料过早失水强度下降。

9.3.2把搅拌好的浇筑料一次性加入到施工面后,打开振动棒进行浇筑振动,振动至浇筑料表面泛浆且无大量气泡溢出为宜,应派专人负责振捣均匀密实。

9.3.3在保温混凝土上浇灌浇筑料时,应在保温混凝土养生期满后进行。 9.4浇筑料的养护

9.4.1水硬性胶结剂(高铝水泥、纯铝酸钙水泥)的衬里,施工后停放至用手指轻按不沾泥浆时,应开始保持表面自然养护≥3天;

9.4.2磷酸盐胶结剂的衬里施工后,应在空气中自然养护≥7天,养护7天应保持干燥,空气的相对湿度不得大于70%,养护期间严禁雨淋不受潮。

9.4.3低水泥衬里施工后,必要时可在现场人员的指导下用塑料薄膜覆盖,或用机油在衬里表面涂刷一层均匀的油膜层,在自然环境中封闭潮湿养护≥3天;

9.4.4衬里养护完成后方可进行运输、吊装或热处理,投产前应做好成品保护; 9.5框架式耐火混凝土炉墙的施工要求

9.5.1钢筋位置要准确,混凝土向火面保护层不小于25mm ,浇灌振捣混凝土时应保证拉钩、托架的位置正确和自由膨胀,膨胀缝应使混凝土完全隔开,并不串位。 9.5.2托架和拉钩处的混凝土应加厚; 9.5.3炉墙施工后的外观要求:

①耐火混凝土表面应平整、光滑,不应有蜂窝、麻面等缺陷;

②耐火混凝土组件外形尺寸偏差为长宽方向一般不大于+3、-5mm ,对角线误差不大于8mm ;

9.6试块

9.6.1耐火混凝土施工前应按设计规定的配合比制成试块,经检验符合下表的要求,方允许施工。

耐火混凝土试块检验项目

注:常温耐压强度试块的细小发丝裂纹可不考虑。

试块需在一定环境,温度下进行养护,以逐步提高混凝土的强度,目前采用高铝水泥耐火混凝土,养护环境宜潮湿,最佳养护为15~25℃, 养护时间大于三昼夜,于浇灌后开始养护一昼夜即可脱膜。

9.6.2施工中做试块,就是耐火混凝土在施工中应在现场进行取样,方法与做试块相同,以鉴定施工质量。

9.6.3在配制耐火混凝土时,应保证其硬化后能达到施工前所做的试块容重、烘干强度、高温残余强度及耐火急冷急热次数,这就要求严格按照试块的配料称量作为实际的配料依据。配料时,无论按重量比或折合成容积比,均保证其标准性,允许误差:

水泥和掺和料不应大于±2%; 粗细骨料不应大于±5%; 10、材料的性能要求

耐磨耐火材料性能要求是按中科院热物理研究所的基础实际要求进行的。

10.2普通耐磨耐火浇注料(其中性能指标必须保证) 安装方式:浇注并震动(捣实)

该浇注料主要用于炉膛密相区,视实际施工需要可加入不锈钢纤维,主要原料为刚玉,为水合自流式浇注料。

10.7硅藻土保温混凝土 (其中性能指标必须保证) 安装方式:浇注并震动(捣实)

10.8矾土水泥耐火混凝土组成和重量配比 10.9矾土水泥混凝土性能指标必须保证:

10.10硅酸钙绝热制品II(w)220型:用于除水冷系统、过热器部分膜式壁外其余炉墙的最外层保温,其理化性能按GB/T10699-1998,最高使用温度1200℃,性能指标必须满足:

10.11抹面料 11、模型制作安装技术要求 11.1模型选材制作

模型材料可以为木材、钢铁、铝制品或塑料。模板用材选用木模时,应根据不同的施工部位,确定模板厚度,并选用优质木材。因炉墙模板要承受炉墙本身的推力和施工振捣时传递到模板上的力,因此模板必须有足够的强度,使其在浇注时不变形,模板向里面应刨光,拼接时各板块之间接缝必须严密,且平面之间应保持整体平整一致。根据施工部位的设计要求留设膨胀缝,制作模板时,可根据膨胀缝的划分将模板分块,在地面进行预组合然后编上序号,按序号将模板依次固定。 11.2模型储存

模型搬运应特别小心,模型变形会导致衬体开裂,预制好的模具应注意防雨及暴晒,最好在干燥的条件下储存防止变形。 11.3支模

耐火浇注料的机械强度通过结合剂与水的化学反应而获得,木制模型将从浇注料中吸收水分,水分不足会降低浇注料的强度,因此木模表面应用脱模油、塑料薄膜、油纸等材料进行隔离。支模前应检查埋入耐火层的抓钉布置是否符合图纸设计要求,并涂刷沥青漆,清理施工部位异物,然后支模,可根据现场的实际情况选用模板固定方式,固定点的布置应尽量考虑不妨碍施工的前提下设置,并确保振捣是不变形。最后检查固定好的模板与施工面的厚度是否完全符合设计规定,如厚度不符合设计要求需要重新支模,保证设计厚度。

12、验收标准及质量检验控制 12.1施工质量验收标准

参照《电力建设施工及验收技术规范》(锅炉机组篇)(DL/T5047-95)的炉墙砌筑条款进行验收,验收内容一览表(见附表) 12.2验收方法

12.2.1所使用的各种耐磨、保温、隔热等材料必须附有产品合格证,完全符合设计要求以及设计单位的变更要求才能使用。

12.2.2在施工耐火耐磨浇注料时,应按施工图设计和施工材料本身的性能的要求,合理留设膨胀缝,其宽度误差为±5mm 。

12.2.3现场混合耐磨耐火浇注料时,其配水比必须准确,搅拌均匀,严格按材料使用工艺要求操作,并做好配料记录。

12.2.4制作安装浇注料的膜板应牢固,无移动和涨模现象,拆模后的浇注料表面气孔率每平方小于15个,并且气孔最大小于5mm,深度小于4mm,孔内颜色必须油黑发亮;模板表面应光滑,接口应严密,无漏浆现象。

12.2.5严格控制成型时间,搅拌好的浇注料,必须在材料厂家规定的时间内浇注完成,否则不能再使用。

12.2.6耐火浇注料、保温浇注料正常脱模原则上不少于24小时,现场条件较好或环境温度≥15℃时应不小于12小时,(具体须依据材料厂家的材料性能要求拆模)。

12.2.7保温浇注料的养护,采用潮湿养护,耐磨耐火浇注料和可塑料为自然养护,在养护过程中,严禁进水或淋雨受潮,否则影响使用质量。

12.2.8检查控制点,衬里部位抓钉焊接或补焊完检查,双层料部位保温材料施工完检查,其他只有一层料施工的部位,施工前对施工部位进行交接验收。 附:验收内容一览表

13、安全文明施工及环境保护 13.1工程安全、健康、环境管理

山东晨鸣纸业集团自备热电厂三期安装工程施工安全、健康、环境管理依据相关法规,企业方针、目标,建立严格的安全管理制度和有效的保证、监督体系,制订并严格执行安全技术、施工措施。

13.2安全管理工作方针

工程在组织实施过程中,贯彻“安全第一,预防为主” 的指导方针,创造安全环境,保证生命健康。

13.3建立工地安全保证体系

安全保证体系

13.4安全技术保证措施

13.4.1贯彻和落实国家有关安全生产的政策和规定,在项目部的领导下制定切实可靠的安全保证措施并严格执行。

13.4.2全面落实各级安全文明施工责任制,建立建全安全风险机制。明确各级责任人的安全文明施工责任,并通过风险共担,利益共享的原则,实行相互监督其责任的落实情况。

13.4.3每周一次工地、班组专业性检查,强化全方位、全过程的安全监察。对查出的问题和隐患执行“三定”原则,限期整改,并跟踪验收。

13.4.4每周由工地组织现场全体施工人员参加安全工作例会,班组执行每天站班会制度,在进行技术交底的同时进行安全工作交底,做到“三交”、“三查”。

13.4.5 落实三级安全教育管理制度,特别是对青工和新进厂工人安全教育管理要落到实处。 13.4.6 开展以班组为单位的安全技能培训,逐步提高职工素质。

13.4.7凡进入施工现场的施工人员必须进行“安规”及相关规定和管理制度的学习,并经考试合格、体检合符要求后,方可执证上岗。特殊工种验证上岗,严格监督管理。

13.4.8坚持一切生产活动都必须有安全技术施工措施,并严格执行规定的审批制度,施工前必须作好交底并签字后才能进行施工。无措施、无交底严禁布置施工。

13.4.9严格规章制度,消灭习惯性违章作业,认真开展施工班组“三查”活动,把安全施工列入整体考核的内容,直接与承包的经济效益挂钩,奖惩斗硬。

13.4.10安监人员深入现场以消灭“三违”为重点,及时制止违章违纪行为。检查和指导施工人员正确使用安全防护用品,对危及人身设备安全的行为有权停止施工,实行安全一票否决制。 13.5施工现场环境保护措施

保证施工人员身体健康,采取一切措施,将由于施工而给场界周围环境带来的不良影响降低到符合环境保护要求范围; 13.6文明施工管理

文明施工是安全施工的基础和有利保障,能够有效的提高生产效益和保证工程质量,改善作业环境和员工精神面貌,展现企业形象和增强企业影响力,本工程的目标是文明施工创一流。 13.6.1施工区域实行谁施工谁负责,施工场地做到“工完料尽场地清”,“一日一清”,杜绝“二次污染”。

13.6.2作好根据施工总平面布置划分的文明施工管理责任区的文明施工工作。

13.6.3施工现场和工具室设备、材料堆放严格执行定置化,并有明确标识,严禁随意无序堆放,更不允许堵塞通道,现场堆放材料仅限于当日使用,特殊情况不得超过三天。

13.6.4施工现场各类管线进行规划,合理布置,并设置明显标识,对电焊二次线、氧乙炔皮管、便携式电源盘(线)要求当天工作完后及时卷(收)回定点位置,移动式氧、乙炔瓶必须有专门搁架放置。

13.6.5现场全部采用钢管脚手架。脚手架搭设应整齐规范,验收挂牌后,方可投入使用。使用过程中,严禁擅自更改脚手架结构和超载。

14、职业健康安全危险源辨识及预防控制

目 录

1、目的 ........................................................................................................................................................................... 3

2、适用范围 ................................................................................................................................................................... 3

3、编制依据 ................................................................................................................................................................... 3

4、作业项目概述 ........................................................................................................................................................... 3

5、作业准备 ................................................................................................................................................................... 3

5.1施工组织机构 ................................................................................................................................................... 3

5.2施工人员配置 .................................................................................................................................................. 4

5.3机械设备配置 .................................................................................................................................................. 4

6、作业条件 ................................................................................................................................................................... 5

6.1施工工期 ........................................................................................................................................................... 5

6.2相关条件 ........................................................................................................................................................... 5

6.3材料管理 ........................................................................................................................................................... 6

6.4材料堆放 ........................................................................................................................................................... 6

7作业顺序 ...................................................................................................................................................................... 6

7.1施工流程 ........................................................................................................................................................... 6

7.2施工进度计划(见附表) ............................................................................................................................... 6

8、作业方法 ................................................................................................................................................................... 6

8.1点火风道(含预燃室) ................................................................................................................................... 6

8.2水冷风室 .......................................................................................................................................................... 8

8.3炉膛(包括密相区,布风板) ...................................................................................................................... 8

8.4水冷屏、过热屏 .............................................................................................................................................. 9

8.5旋风分离器 ...................................................................................................................................................... 9

8.6返料器及返灰通道 ........................................................................................................................................ 10

8.7水平烟道 ........................................................................................................................................................ 10

8.8省煤器炉墙 .................................................................................................................................................... 11

9、耐火、保温混凝土施工技术要求 ......................................................................................................................... 11

9.1施工前的准备工作 ......................................................................................................................................... 11

9.2耐火混凝土搅拌的要求 ................................................................................................................................. 11

9.3成型 ................................................................................................................................................................. 11

9.4浇筑料的养护 ................................................................................................................................................. 12

9.5框架式耐火混凝土炉墙的施工要求 ............................................................................................................. 12

9.6试块 ................................................................................................................................................................. 12

10、材料的性能要求 ................................................................................................................................................... 13

11、模型制作安装技术要求 ....................................................................................................................................... 17

11.1模型选材制作 ............................................................................................................................................... 17

11.2模型储存 ....................................................................................................................................................... 17

11.3支模 ............................................................................................................................................................... 17

12、验收标准及质量检验控制 ................................................................................................................................... 18

12.1施工质量验收标准 ....................................................................................................................................... 18

12.2验收方法 ....................................................................................................................................................... 18

13、安全文明施工及环境保护 ................................................................................................................................... 19

13.1工程安全、健康、环境管理 ....................................................................................................................... 19

13.2安全管理工作方针 ....................................................................................................................................... 19

13.3建立工地安全保证体系 ............................................................................................................................... 19

13.4安全技术保证措施 ....................................................................................................................................... 20

13.5施工现场环境保护措施 ............................................................................................................................... 20

13.6文明施工管理 ............................................................................................................................................... 20

14、职业健康安全危险源辨识及预防控制 ............................................................................................................... 22

1、目的

编制本作业指导书的目的是为了本专业施工人员更具体的了解工程的施工技术要求,并进行技术和资源的准备工作,同时也为了施工进程的顺利开展和现场的合理布置,尽量发挥我公司的优势,合理的组织施工,科学的进行管理,努力采用新技术,有效的利用人力、物力、安排空间和时间组织安全文明施工,注意保护环境,以及实现安全、优质、准点、文明、低耗,取得更大的技术经济效果。

2、适用范围

××集团自备电厂安装2台YG-600/9.8-M型自然循环流化床锅炉炉墙砌筑工程。

3、编制依据

3.1部颁《电力建设施工及验收技术规范》(锅炉机组篇)DL/T5047-95

3.2《工业炉砌筑工程施工及验收技术规范》(GBJ211-87)

3.3《电力建设安全工作规程》(DL50091-92)

3.4我公司的企业标准QB/LA10100-2000质量手册及相关程序文件。

3.5济南锅炉厂提供的砌砖图

3.6设计院提供的《设计说明书》

4、作业项目概述

4.1本类型锅炉是由济南锅炉厂设计制造的YG-600/9.8-M型自然循环流化床锅炉。是一种高效低污染新型155MW 燃煤燃烧设备, 锅炉炉墙分为:热烟发生器(预燃室)、点火风道、水冷风室、炉膛燃烧室、炉膛出口(含屏过)、旋风分离器入口烟道、旋风分离器、返料器、旋风分离器出口烟道、平衡烟道及尾部对流烟道等部分。该类型锅炉炉型为:高温高压自然循环燃烧方式,平衡通风、露天布置、固态排渣、其内衬耐火(耐磨)、保温材料。安装工程量较大(大约1600T ),而且交叉部位多,与同类炉相比有许多特殊之处,炉墙的砌筑是非常关键的工序并有其特殊要求,必须保证炉墙的严密性和确保炉墙长期经受高温、振动,确保锅炉长期安全、正常运行。

4.2 工艺流程

被破碎筛分后的煤和起脱硫作用的石灰石,经料仓和输送设备送至燃烧室,在一、二次风的作用下产生流化沸腾燃烧,高温的烟气以5m/s速度裹着不断输进的固体颗粒沿炉膛上升。所产生的热量以辐射的形式传递到冷壁管上,然后继续上升由炉膛出口以25m/s的速度进入旋风分离器,燃烧后的烟气经旋风分离后,未燃尽颗粒通过返料器,在高压返料风的作用下返回燃烧室循环燃烧,已燃尽的微颗粒在高温烟气的作用下经过平衡烟道进入尾部烟道,通过高、低温过热器、省煤器、空气预热器、电除尘、最后在引风机的作用下经过烟囱排放到大气中。

5、作业准备

5.1施工组织机构

5.2施工人员配置

针对该筑炉工程,须组织有丰富安装经验的管理人员和工人进驻现场,以最优秀的施工质量,最科学的工艺和最短的工期,安全文明的完成施工任务。

5.3机械设备配置

施工机具设备配置是否合理和完善,将直接影响施工进度和施工质量,本工程必须投入性能最佳匹配完善的施工机具,以确保施工工期和施工质量。

6、作业条件

6.1施工工期

以水压试验完成并验收合格,具备施工条件之日计算,每台炉全部内衬材料安装,绝对施工工期60天(水压试验前完成非承压结构件内衬材料的80%工程量)。

6.2相关条件

6.2.1施工前应具备“三通一平”,即施工用电接到锅炉零米层,施工合格水接到锅炉零米层,运料道路畅通,施工现场堆料场地平整,排水畅通,具备堆放材料,运输车能到场地卸车,场区面积大约350㎡左右。

6.2.2施工现场应提供拌料场地和木模预制场地,为了保证浇注料的施工质量,拌料场地应靠近锅炉,以缩短运料时间。

6.2.3在交付给内衬料施工时,原则上应具备以下条件;

6.2.3.1炉膛(水压实验后)

一次、二次风管、给料管、仪表套管、排渣管即返气管、人孔门框都已安装完毕,炉膛鳍片拼接焊缝全部焊接结束,锅炉管拼接处及局部脱落的销钉补焊完,焊瘤打磨光滑,布风板风嘴安装完毕. (可以在全部施工完后 ,拆除脚手架并清理干净再安装风嘴,防止砸坏风嘴,最后施工布风板浇注料。)

6.2.3.2回料系统

按锅炉厂设计要求及通过安装程序,回料阀仪表开孔(含套管)以及高压风管全部安装完毕,布风嘴安装结束,人孔门框安装就位,设备已安装验收。

6.2.3.3旋风分离器

已安装就位,所有的拼接焊缝满焊完,人孔已安装好,仪表开孔或套管安装完,安装临时的支撑金属焊接件已撤除,炉膛出口与分离器进口间的膨胀节已安装定位。

6.2.3.4平衡烟道

已吊装就位,所有的拼接焊缝符合要求,平衡烟道与高过连接的出口三维膨胀节的安装尺寸已定位。

6.2.3.5外部条件

所有的人孔外走道钢架及平台扶梯和栏杆安装完毕,具备安全的运料砌筑条件。

6.3材料管理

6.3.1材料进场及领用

6.3.2根据施工进度计划的安排,排出材料进场计划,按照计划发运材料。

6.3.3材料到场后,首先检查有无出场合格证和质保书,证件齐全,材料名称核对正确后再登记入库或堆放到指定位置。

6.3.4使用材料时,必须由专人负责领用,以免弄错或用错材料,造成运行的使用质量隐患。

6.3.5每天应建立材料使用及库存数量记录,提供给发货计划人,协调材料发货和运输安排。

6.4材料堆放

6.4.1堆放材料分门别类摆放至指定位置,并挂上表示牌,注明材料种类、数量、批号。

6.4.2成品、半成品分开堆放,并挂标识牌。

6.4.3预制好的施工模板分类摆放,挂上标识牌,注明各种参数和使用部位,以利施工时使用和不会错用。

6.4.4做好标识管理资料,以便进行材料数量和品种的帐目校对,以及各使用部位的材料数量统计。

7作业顺序

7.1施工流程

施工准备→预燃室(点火器)→点火风道→一次风道→水冷风室→返灰通道→返料器→料腿→旋风分离器锥体→旋风分离器直筒→旋风顶→炉膛密相区→水冷屏→过热屏→出烟屏→分离器入口→分离器出口→水平烟道→省煤器炉墙→门类炉墙→竣工清理

7.2施工进度计划(见附表)

8、作业方法

循环硫化床工况表明,炉墙砌筑工程非常关键,施工质量直接关系到炉墙的严密性、抗热振稳定性、抗磨损和保温隔热性能。因此施工工艺必须科学、严谨才能对施工过程进行严格的质量控制,以确保锅炉安全、有效、长寿运行。

8.1点火风道(含预燃室)

每台锅炉设计有4个点火风道,在风室后墙左右对称布置。点火风道耐火材料施工因其外

形为圆筒型,施工工艺较复杂,且点火工作温度最高(点火预燃室1300℃-1500℃, 点火风道900℃-1200℃),并且由于根部风和周围风压调节匹配及油枪给油压力和雾化较果的问题,极容易造成柴油积聚爆燃和附着燃烧,造成局部超高温。点火风道在点火时处于热振及高温状态,耐火材料的选择,施工方法的优劣,将直接影响施工质量。

8.1.1预燃室:浇注抗热振浇注料(≈3.74m ³) ,浇注厚度δ=50mm, 成型尺寸φ=1300mm ,筒内设置靶钉,无需焊接钩钉及网格绑扎,此项工作建议地面施工(如安装后施工困难,施工质量难以保证),养护期后再进行安装。每台预燃室风冷夹套上设计有30个风口,耐火材料施工时,风口处要圆滑过渡,并做好密封,防止耐火材料进入风冷夹套内。施工后要对每个风口检查、清理确保畅通。预燃室中沿筒体方向均匀布置10道膨胀缝,并与其垂直布置了5道环形膨胀缝,施工时,采用五合板或木制板制成“z ”型预埋浇注材料中,待烘炉后自然形成一道δ=5mm 的膨胀缝。

注意事项:

①此部位施工前金属靶钉表面涂刷沥青δ=2mm ,耐热销钉可不涂沥青。

②耐火材料要有较高的抗热振稳定性,且不易脱落。

③支模尺寸准确,形状、角度符合设计,要求模板平整无孔洞,无台阶,易脱模,支撑要求牢固,严禁跑模现象出现,支撑方木不小于400mm ×60mm 。

8.1.2点火风道、一次风道

点火风道内壁设置“Y ”型抓钉,每个抓钉长度为225mm ,埋人浇注材料部分预涂刷二道沥青δ=2mm ,以保证热态时抓钉可以自由膨胀,总厚度设计为δ=250mm 。保温层采用4a 号硅酸铝棉毡(≈38 m³,含一次风道),δ=180mm ,浇注抗热震浇注料(≈13.5 m³,含一次风道),浇注厚度δ=70mm ,成型尺寸Φ=2000mm ,风筒中有10道环形膨胀缝,与这些膨胀缝垂直的膨胀缝间距是600mm ,采用五合板或木制板制成“Z ”型预埋浇注料中,待烘炉后就自然形成5mm 的膨胀缝,因其设计为圆形如果安装后施工,顶部工作比较困难,施工质量难保证,建议此项工作再地面施工,养护期后再进行安装。

注意事项:①注意预留安装间隙。

②施工浇注料前,硅酸铝棉毡表面应喷涂防水成膜材料防止浇注水分损失。

③必须保证“Y ”型抓钉至向火面浇注料保护层≥25mm 。

④模具尺寸要准确,符合设计,要求模板无孔洞,无台阶,易脱模,支撑要求牢固,

严禁跑模,两侧可以对称施工,增加斜拉 ,构成三角形稳定结构。

8.1.3一次风道施工工艺与点火风道相同,其成型尺寸:Φ=1900mm.

注意事项:

一次风道与点火风道相交处,耐火材料膨胀应力方向发生了改变,两个方向集中到一起,易使材料脱落。采取措施:①拐角处不留膨胀缝。两侧膨胀距拐角为300mm 。②加密焊接“U ”

型销钉,(或绑扎钢筋网络)间距为150mm ,防止耐火材料起拱、脱落。

8.2水冷风室

8.2.1水冷风室是炉膛和点火风道的媒体,承担着火焰输送任务,工作温度850℃~900℃,风速>20m/s,炉墙耐火材料为抗热震浇注料(≈15M ³)侧面与底部和顶部均为δ=70mm.

8.2.1.1水冷风室底部为震捣抹平无需支模,侧墙需支模浇注,施工时下层模浇注完毕后就位上层模板, 并与下层模板连接为一整体, 上层模板浇注完毕后拆除下层模板,即倒模施工,浇注料施工时,材料搅拌均匀(按材料厂家配比说明严格控制)将搅拌好的材料用容器运至现场注入模具内,震捣时间和施工方法,严格按浇注料施工技术要求施工。

8.2.1.2水冷风室顶部浇注困难极大,并有风帽、管孔。建议耐磨材料为锆莫来石可塑料,浇注厚度δ=70mm (≈4.78M ³)此处施工有两种方法:①安装后施工,要求填塞密实,施工不宜过宽,一般为100~200的模板,可塑料由模板和管排之间一点一点填塞,施工时下方敷一层塑料布,并将失落的可塑料及时回收利用。②安装前施工,即地面施工,将水冷风室顶倒置,无需支模振捣抹平即可。养护期后再进行安装。(注意预留安装间隙)

8.2.3注意事项:

①浇注料施工前销钉上和布风板风帽预先涂刷二道沥青漆δ=2mm 。

②销钉至向火面方向,浇注料保护层≥25mm 。

③风室后墙与点火风道相交处施工工艺见1.3一次风道施工注意事项。

8.2.4模具制安:

支模尺寸应准确,形状、角度符合设计要求,模板平整无孔洞、无台阶 ,制作好的模板上在固定前刷上脱模剂,以便脱模时不损坏施工表面,在固定模板时高度不宜过高,应根据施工条件而定,以方便浇捣为宜,制好的模板应能承受一定的撑力,使其在浇注时不变形。

8.3炉膛(包括密相区,布风板)

8.3.1CFB 锅炉在运行中,炉膛内部气、固两相流的工况极为复杂,大量的回混物料严重冲蚀着四周炉墙,密向区炉墙有两个人孔,四个启动燃烧器孔,两个返料入口,六个给煤口和二十四个二次风入口及多个测温测压孔,这些结合部位属于重磨损区,由于膨胀应力发生了方向改变,两个方向集中到结合处易出现材料脱落损伤蒸气管,施工中应重点控制。四侧水冷壁防磨区与水冷壁的过渡区域,此区域磨损是由沿壁下行的物料冲刷造成,此处要求必须按图施工,留出相同的倒角以破除涡流,从而减少沿壁面下行的物料流冲刷。

8.3.2此处施工经水压试验合格及截止线处金属喷涂后进行。因炉膛内烟气流速5.2m/s,温度850℃~900℃,炉墙耐火材料选用钢纤维自流式耐磨浇注料。截至线至拐点区域浇注厚度δ=73mm ,其它部位浇注厚度δ=70mm ,密向区四面墙均设有垂直膨胀缝,其深度和宽度要满足耐火材料的膨胀要求,在支模板时将两层五合板或木制板预埋浇注料中,其缝中的硅酸铝(或石棉绳)可在烘炉后填塞,填塞时可涂抹高温胶泥并将硅酸铝耐火纤维填平捣实。

8.3.3各孔洞处施工:为了防止各孔洞结合部位浇注料脱落,在孔洞周围300mm 范围内增加100mm ×100mm Φ6钢筋网格,材质为1Cr25Ni20Si2, 将耐热钢筋网格一端与水冷壁扁钢锚固,另一端与Y 型销钉及外护板锚固,并涂δ=2mm 沥青。截至线处齿带结构及四角倒三角斜坡处施工,结合部位要圆滑过渡。

8.3.4布风板上设计由内嵌风帽2351只和5个放渣管,风帽埋于浇注料部分先用δ=2mm 硅棉垫包覆,有利于其膨胀及检修时更换。风帽上的小孔在浇注前用塑料带封好,防止浇注料堵塞,施工后对每个风口检查、清理、确保畅通。此处设计硅澡土保温混凝±δ=80mm ,自流式耐磨浇注料δ=70mm 。

8.3.5注意事项:

①二次风喷嘴、给煤喷嘴,耐热钢筋网格及靶钉等埋入浇注料中的所有铁件在浇注前均涂刷沥青漆δ=2mm 。

②耐热钢筋网焊接锚固及靶钉补焊时,应用材质与其相适应的焊条。

③钢筋网格及靶钉至向火面浇注料保护层≥25mm.

8.4水冷屏、过热屏

8.4.1水冷屏、过热屏、出烟屏工作温度约900℃,烟气表观速度6m/s。浇注自流式耐磨浇注料(或耐磨可塑料)δ=70mm ,炉膛内垂直布置的水冷屏与过热器底部浇注料由于膨胀应力容易造成脱落,应增加耐热钢筋材质为1Cr25Ni20Si2。做成“U ”型网格,间距为100mm ,用相应材质的焊条焊接在靶钉上,防止耐火材料脱落,“U ”型钢筋网至向火面浇注料保护层≥25mm 。

8.4.2注意事项:

①穿顶穿墙处部件包裹3mm 硅棉垫。

②靶钉及耐热钢筋表面涂沥青漆二道。

③金属喷涂应在浇注前完成。

④所有施工面要密实,杜绝孔洞,确保施工质量,操作方法见2.1.1。

8.5旋风分离器

8.5.1整台锅炉有2个旋风分离器入口烟道,后墙左右对称布置,烟气通过这里携带物料颗粒流入旋风分离器,流速急剧增加(由6m/s增至26m/s)工作温度850℃~900℃,烟气颗粒浓度达150kg/Nm3. 对炉墙磨损较为严重。埋管区炉墙四周增加Φ6耐热钢筋网格150mm ×150mm (1Cr25Ni20Si2)浇注料保护层≥25mm ,三维膨胀处炉墙沿方环设置的膨胀缝宽度为80mm ,用于吸收炉膛与分离器之间的相对膨胀量,曲折膨胀缝,可防夹灰并增加气密性。

8.5.2旋风分离器炉墙结构总厚度δ=360mm ,微孔硅酸钙保温砖δ=200mm ,硅酸铝毡δ=70mm ,旋风入口直段炉墙,旋风顶炉墙及旋风出口炉墙耐火材料为钢玉耐磨浇注料δ=90mm ,旋风锥体及料腿耐火材料为普通耐磨浇注料δ=90mm 。

8.5.3微孔硅酸钙异型砖砌筑:由于“Y ”行抓钉安装焊接使此项的砌筑工作困难较大。砖槽的

尺寸与抓钉的尺寸(300mm ×300mm )不象理论设计那样十分准确,砌筑可以和焊接抓钉同时施工,保温砖砌筑灰缝不大于5mm, 且灰缝均匀饱满, 在砌筑不方便的部位, 应用保温混凝土填实。施工工艺应严格按耐火材料厂家提供的工艺标准执行,保证施工质量。

8.5.5浇注料施工难度较大,模具制作困难,膨胀缝设置复杂,每块膨胀体相互咬合,相互牵压,施工时以分隔块进行,并跳跃施工(即先浇1.3.5再浇2.4.6一次类推),曲折施工缝,侧面粘5mm 硅酸铝纤维毡。模板要承受炉墙本身的推力和施工振捣时传递到模板上的力及其外部因素,因此模板要有足够的强度,支设必须牢固,尺寸准确,其支设方法根据现场具体情况定。 注意事项:

①“Y ”行抓钉,耐热钢筋网等埋入浇注料部分先涂刷沥青δ=2mm 。

②“Y ”型抓钉焊接要牢固,分叉钉端至浇注料表面保护层≥25mm 。

8.6返料器及返灰通道

8.6.1除接点处,各区域典型衬层结构为:总厚度360mm ,刚玉耐磨浇注料δ=90mm ,硅酸铝毡δ=70mm ,微孔硅酸钙制品δ=200mm ,所有浇注区用“Y ”型抓钉固定。

8.6.2由分离器分离下来的物料,通过料腿进入返料器,工作温度约950℃,烟速1-2m/s,灰料浓度高达3500kg/Nm³。成形尺寸为Φ1500mm, 此部位设计结构复杂,作业空间狭窄。施工难度大,不容易进行质量控制,并且属于重磨损区,振动较大,易使材料相互挤兑、销钉炭化造成脱落,影响返料,是最容易出现质量问题的部位,施工中应重点控制施工质量。

8.6.3注意事项:

①施工浇注前硅酸铝毡表面应喷涂防水成膜材料防止浇注水分损失。

②金属支撑件表面应涂沥青δ=2mm 。

③浇注施工以分隔块进行,曲折施工缝,侧面贴硅酸铝毡。

④阀体过桥处浇注料应加钢纤维,并设置止裂圆槽,利于消除过桥应力。

⑤返灰通道与炉膛结合部位的耐热钢筋网焊接要牢固。

⑥导灰管和顺灰管之间的硅酸铝毡在安装前填实。

8.7水平烟道

由旋风分离器流出的烟气颗粒浓度很小约60kg/ Nm³, 对炉墙材料构成磨损较轻,工作温度700℃-900℃,烟气流速约28m/s。顶棚过热器包墙布满靶钉,总厚度为270mm ,浇注自流式耐磨材料δ=70mm (或可塑料)顶棚上180mm 硅酸铝毡保温20mm 抹面料。12根Φ159包覆管为50mm 自流式耐磨浇注料。其余各区域结构是典型的板式炉墙结构,总厚度360mm ,90mm 普通耐磨浇注料、70mm 硅酸铝毡、200mm 微孔硅酸钙保温砖。除顶棚处,所有浇注区用“Y ”型抓钉固定。 注意事项:

①施工浇注料前,硅酸铝毡表面喷涂防水成膜材料,防止浇注水分损失。

②金属支撑件表面应涂沥青漆二道。

③12跟包覆管浇注料中增加耐热钢筋网格120mm ×120mm (1Cr25Ni20Si2) ④浇注施工以分隔块进行, 并跳跃施工, 曲折施工缝, 侧面贴硅酸铝毡. 8.8省煤器炉墙

携带粒子烟气流经该处逐渐减小约12m/s,灰颗粒浓度很小约60kg/Nm³, 工作温度600-700℃之间。对材料磨损较轻。炉墙总厚度220mm. 90mm 矾土水泥耐火混凝土,130mm 微气硅酸钙保温砖,所有浇注区用“Y ”型抓钉固定。 注意事项

①金属支撑件表面应涂沥青油漆二道。

②浇注施工以分隔进行并跳跃施工,曲折施工缝,侧面贴硅酸铝毡。 9、耐火、保温混凝土施工技术要求 9.1施工前的准备工作

9.1.1浇筑料在运抵现场时,应确保搅拌前干燥、无结块现象,暂时不用的料应储存在干燥、防潮和防火的地方。

9.1.2需要支设模具的地方,严格按照规定尺寸做好并将其固定牢固。

9.1.3施工部位清理干净,内壁不得黏附杂物,预埋金属件(锚固件)浇筑金属面在浇筑前涂2毫米沥青漆。

9.1.4采用强制式搅拌机并选用高频振动棒振动成型。 9.2耐火混凝土搅拌的要求

9.2.1宜采用强制式搅拌机按规定的时间搅拌均匀,严禁混入任何杂物。同时根据现场施工实际需要,安排其它施工机械、器具如小磅秤、加水桶、插入式或平板式振动器等。

9.2.2耐火混凝土应按施工配合比进行配制,加液量应根据施工配合比和现场的温度、湿度及湿料的运输距离确定,不得随意增减,如超出加液量范围应及时通知厂家现场处理。

9.2.3每次搅拌量不宜太多,搅拌好的湿料应在规定的时间用完,超过凝结时间的湿料,严禁二次加液使用。

9.2.4掺入钢纤维时,应将钢纤维均匀撒入干混合料内,搅拌时间不小于1min 。加水搅拌后的湿料中,钢纤维应分布均匀,不得有成团现象。

9.2.5不同种类不定型浇注料所用搅拌机严禁混合使用,尽量做到一种浇注料,一个搅拌机;换料时要求把搅拌机刷净凉干。 9.3成型

9.3.1对于多孔吸水表面,施工前应充分用水喷湿,及采取特殊防吸水措施,以防止浇筑料过早失水强度下降。

9.3.2把搅拌好的浇筑料一次性加入到施工面后,打开振动棒进行浇筑振动,振动至浇筑料表面泛浆且无大量气泡溢出为宜,应派专人负责振捣均匀密实。

9.3.3在保温混凝土上浇灌浇筑料时,应在保温混凝土养生期满后进行。 9.4浇筑料的养护

9.4.1水硬性胶结剂(高铝水泥、纯铝酸钙水泥)的衬里,施工后停放至用手指轻按不沾泥浆时,应开始保持表面自然养护≥3天;

9.4.2磷酸盐胶结剂的衬里施工后,应在空气中自然养护≥7天,养护7天应保持干燥,空气的相对湿度不得大于70%,养护期间严禁雨淋不受潮。

9.4.3低水泥衬里施工后,必要时可在现场人员的指导下用塑料薄膜覆盖,或用机油在衬里表面涂刷一层均匀的油膜层,在自然环境中封闭潮湿养护≥3天;

9.4.4衬里养护完成后方可进行运输、吊装或热处理,投产前应做好成品保护; 9.5框架式耐火混凝土炉墙的施工要求

9.5.1钢筋位置要准确,混凝土向火面保护层不小于25mm ,浇灌振捣混凝土时应保证拉钩、托架的位置正确和自由膨胀,膨胀缝应使混凝土完全隔开,并不串位。 9.5.2托架和拉钩处的混凝土应加厚; 9.5.3炉墙施工后的外观要求:

①耐火混凝土表面应平整、光滑,不应有蜂窝、麻面等缺陷;

②耐火混凝土组件外形尺寸偏差为长宽方向一般不大于+3、-5mm ,对角线误差不大于8mm ;

9.6试块

9.6.1耐火混凝土施工前应按设计规定的配合比制成试块,经检验符合下表的要求,方允许施工。

耐火混凝土试块检验项目

注:常温耐压强度试块的细小发丝裂纹可不考虑。

试块需在一定环境,温度下进行养护,以逐步提高混凝土的强度,目前采用高铝水泥耐火混凝土,养护环境宜潮湿,最佳养护为15~25℃, 养护时间大于三昼夜,于浇灌后开始养护一昼夜即可脱膜。

9.6.2施工中做试块,就是耐火混凝土在施工中应在现场进行取样,方法与做试块相同,以鉴定施工质量。

9.6.3在配制耐火混凝土时,应保证其硬化后能达到施工前所做的试块容重、烘干强度、高温残余强度及耐火急冷急热次数,这就要求严格按照试块的配料称量作为实际的配料依据。配料时,无论按重量比或折合成容积比,均保证其标准性,允许误差:

水泥和掺和料不应大于±2%; 粗细骨料不应大于±5%; 10、材料的性能要求

耐磨耐火材料性能要求是按中科院热物理研究所的基础实际要求进行的。

10.2普通耐磨耐火浇注料(其中性能指标必须保证) 安装方式:浇注并震动(捣实)

该浇注料主要用于炉膛密相区,视实际施工需要可加入不锈钢纤维,主要原料为刚玉,为水合自流式浇注料。

10.7硅藻土保温混凝土 (其中性能指标必须保证) 安装方式:浇注并震动(捣实)

10.8矾土水泥耐火混凝土组成和重量配比 10.9矾土水泥混凝土性能指标必须保证:

10.10硅酸钙绝热制品II(w)220型:用于除水冷系统、过热器部分膜式壁外其余炉墙的最外层保温,其理化性能按GB/T10699-1998,最高使用温度1200℃,性能指标必须满足:

10.11抹面料 11、模型制作安装技术要求 11.1模型选材制作

模型材料可以为木材、钢铁、铝制品或塑料。模板用材选用木模时,应根据不同的施工部位,确定模板厚度,并选用优质木材。因炉墙模板要承受炉墙本身的推力和施工振捣时传递到模板上的力,因此模板必须有足够的强度,使其在浇注时不变形,模板向里面应刨光,拼接时各板块之间接缝必须严密,且平面之间应保持整体平整一致。根据施工部位的设计要求留设膨胀缝,制作模板时,可根据膨胀缝的划分将模板分块,在地面进行预组合然后编上序号,按序号将模板依次固定。 11.2模型储存

模型搬运应特别小心,模型变形会导致衬体开裂,预制好的模具应注意防雨及暴晒,最好在干燥的条件下储存防止变形。 11.3支模

耐火浇注料的机械强度通过结合剂与水的化学反应而获得,木制模型将从浇注料中吸收水分,水分不足会降低浇注料的强度,因此木模表面应用脱模油、塑料薄膜、油纸等材料进行隔离。支模前应检查埋入耐火层的抓钉布置是否符合图纸设计要求,并涂刷沥青漆,清理施工部位异物,然后支模,可根据现场的实际情况选用模板固定方式,固定点的布置应尽量考虑不妨碍施工的前提下设置,并确保振捣是不变形。最后检查固定好的模板与施工面的厚度是否完全符合设计规定,如厚度不符合设计要求需要重新支模,保证设计厚度。

12、验收标准及质量检验控制 12.1施工质量验收标准

参照《电力建设施工及验收技术规范》(锅炉机组篇)(DL/T5047-95)的炉墙砌筑条款进行验收,验收内容一览表(见附表) 12.2验收方法

12.2.1所使用的各种耐磨、保温、隔热等材料必须附有产品合格证,完全符合设计要求以及设计单位的变更要求才能使用。

12.2.2在施工耐火耐磨浇注料时,应按施工图设计和施工材料本身的性能的要求,合理留设膨胀缝,其宽度误差为±5mm 。

12.2.3现场混合耐磨耐火浇注料时,其配水比必须准确,搅拌均匀,严格按材料使用工艺要求操作,并做好配料记录。

12.2.4制作安装浇注料的膜板应牢固,无移动和涨模现象,拆模后的浇注料表面气孔率每平方小于15个,并且气孔最大小于5mm,深度小于4mm,孔内颜色必须油黑发亮;模板表面应光滑,接口应严密,无漏浆现象。

12.2.5严格控制成型时间,搅拌好的浇注料,必须在材料厂家规定的时间内浇注完成,否则不能再使用。

12.2.6耐火浇注料、保温浇注料正常脱模原则上不少于24小时,现场条件较好或环境温度≥15℃时应不小于12小时,(具体须依据材料厂家的材料性能要求拆模)。

12.2.7保温浇注料的养护,采用潮湿养护,耐磨耐火浇注料和可塑料为自然养护,在养护过程中,严禁进水或淋雨受潮,否则影响使用质量。

12.2.8检查控制点,衬里部位抓钉焊接或补焊完检查,双层料部位保温材料施工完检查,其他只有一层料施工的部位,施工前对施工部位进行交接验收。 附:验收内容一览表

13、安全文明施工及环境保护 13.1工程安全、健康、环境管理

山东晨鸣纸业集团自备热电厂三期安装工程施工安全、健康、环境管理依据相关法规,企业方针、目标,建立严格的安全管理制度和有效的保证、监督体系,制订并严格执行安全技术、施工措施。

13.2安全管理工作方针

工程在组织实施过程中,贯彻“安全第一,预防为主” 的指导方针,创造安全环境,保证生命健康。

13.3建立工地安全保证体系

安全保证体系

13.4安全技术保证措施

13.4.1贯彻和落实国家有关安全生产的政策和规定,在项目部的领导下制定切实可靠的安全保证措施并严格执行。

13.4.2全面落实各级安全文明施工责任制,建立建全安全风险机制。明确各级责任人的安全文明施工责任,并通过风险共担,利益共享的原则,实行相互监督其责任的落实情况。

13.4.3每周一次工地、班组专业性检查,强化全方位、全过程的安全监察。对查出的问题和隐患执行“三定”原则,限期整改,并跟踪验收。

13.4.4每周由工地组织现场全体施工人员参加安全工作例会,班组执行每天站班会制度,在进行技术交底的同时进行安全工作交底,做到“三交”、“三查”。

13.4.5 落实三级安全教育管理制度,特别是对青工和新进厂工人安全教育管理要落到实处。 13.4.6 开展以班组为单位的安全技能培训,逐步提高职工素质。

13.4.7凡进入施工现场的施工人员必须进行“安规”及相关规定和管理制度的学习,并经考试合格、体检合符要求后,方可执证上岗。特殊工种验证上岗,严格监督管理。

13.4.8坚持一切生产活动都必须有安全技术施工措施,并严格执行规定的审批制度,施工前必须作好交底并签字后才能进行施工。无措施、无交底严禁布置施工。

13.4.9严格规章制度,消灭习惯性违章作业,认真开展施工班组“三查”活动,把安全施工列入整体考核的内容,直接与承包的经济效益挂钩,奖惩斗硬。

13.4.10安监人员深入现场以消灭“三违”为重点,及时制止违章违纪行为。检查和指导施工人员正确使用安全防护用品,对危及人身设备安全的行为有权停止施工,实行安全一票否决制。 13.5施工现场环境保护措施

保证施工人员身体健康,采取一切措施,将由于施工而给场界周围环境带来的不良影响降低到符合环境保护要求范围; 13.6文明施工管理

文明施工是安全施工的基础和有利保障,能够有效的提高生产效益和保证工程质量,改善作业环境和员工精神面貌,展现企业形象和增强企业影响力,本工程的目标是文明施工创一流。 13.6.1施工区域实行谁施工谁负责,施工场地做到“工完料尽场地清”,“一日一清”,杜绝“二次污染”。

13.6.2作好根据施工总平面布置划分的文明施工管理责任区的文明施工工作。

13.6.3施工现场和工具室设备、材料堆放严格执行定置化,并有明确标识,严禁随意无序堆放,更不允许堵塞通道,现场堆放材料仅限于当日使用,特殊情况不得超过三天。

13.6.4施工现场各类管线进行规划,合理布置,并设置明显标识,对电焊二次线、氧乙炔皮管、便携式电源盘(线)要求当天工作完后及时卷(收)回定点位置,移动式氧、乙炔瓶必须有专门搁架放置。

13.6.5现场全部采用钢管脚手架。脚手架搭设应整齐规范,验收挂牌后,方可投入使用。使用过程中,严禁擅自更改脚手架结构和超载。

14、职业健康安全危险源辨识及预防控制


相关内容

  • 水冷壁管更换施工工艺
  • 40/H锅炉水冷壁管更换 施工方案 编制单位:江苏静安工业设备安装有限公司 编制日期:2014年9月2日 第一章 第二章 第三章 第四章 第五章 第六章 第七章 目 录 改造工程概况 施工机械.工具.量具配置计划 施工组织机构设置及劳动力配置 主要施工方案及措施 技术管理 安全管理 文明施工管理 1 ...

  • 燃煤热水锅炉安装工程施工组织设计方案
  • 安装工程施工组织设计方案 XXX 有限公司锅炉房改造工程 SHL58-1.6/150/90-S SHL91-1.6/150/90-AII 锅炉安装工程施工组织设计 编制: XXX 审核: XXX 批准: XXX XXX 有限公司 日期:二0一七年七月 1. 工程概况 XXX 有限公司锅炉房现有五台热 ...

  • 某燃气锅炉安装工程施工组织设计
  • Xxxxxxxxxxx型全自动燃气蒸气锅炉 施 工 组 织 设编制: 审核: 批准: Xxxxxxxxxxxx公司 Xxxx年x月x日 计 目 录 一.工程概况 二.施工前的准备 三.施工方案 四.消防生产措施 五.施工进度计划保证措施 六.环保方案.文明施工.控制扬尘措施 一.工程概况: Xx厂现 ...

  • 锅炉安装质量证明书
  • 锅炉安装质量证明书 锅炉使用单位: 锅炉名称.类别及型号:产品出厂编号:锅炉安装地址:安装许可证号: 单位内编号: 该台锅炉由本安装单位负责安装,特此证明安装质量符合<<锅炉安全技术监察规程>>和有关验收标准规定. (安装单位公章) 日期: 年 月 日 安装单位名称:地址: ...

  • 青岛某热力公司锅炉拆除.安装工程施工组织设计
  • 青 岛 XXXX 热 力 公 司 锅炉拆除.安装工程 施工组织设计 中国第二十二冶金建设公司 二零零五年六月三日 一.编制说明 1.本施工组织设计是为青岛金泉热力公司锅炉拆除.安装工程投标需要编制的,其宗旨是在经济上合理,技术上可行.可靠安全的前提下,满足业主提出的要求. 2.本施工组织设计编制的依 ...

  • 办公区及生活区临建施工方案
  • 正文目录 1 编制说明 .......................................................................................................... 3 2 编制依据 ...................... ...

  • 热水锅炉土建工程施工组织设计
  • 热水锅炉土建工程 施工组织设计 山东*******限公司 二0一四年六月十五日 第一章 施工组织设计 一.工程概况: 1.热水锅炉土建工程位于**有限公司生产厂区内,该工程建筑面积约1550平方米,15-19轴.B-C间地上五层,檐高26.5米,15-19轴.C-D轴为锅炉房,锅炉房地上2层,女儿墙 ...

  • 建筑冬季施工方案
  • 秋季现已过去,冬季已经到来,工程施工将进入冬季施工,冬季施工因施工分项工程不同,要求有所不同。冬季施工的起止日期为:当冬天到来时,如连续五天的日平均气温稳定在5℃以下,则此5d的第一天为进入冬季施工的初日,当气温转暖时,最后一个5d的日平均气温稳定在5℃以上,则此5d的最后一天为冬季施工的终日 ...

  • 锅炉烘炉运行方案
  • 莲花股份有限公司集中供热项目 1*45t/h锅炉烘炉方案 莲花股份工程有限公司 二零一〇年十二月 目 录 1.烘炉的目的„„„„„„„„„„„„„„„„„„„„„(3) 2.烘炉基本原则„„„„„„„„„„„„„„„„„„„„(4) 3.烘炉应具备的条件„„„„„„„„„„„„„„„„„(4) 4烘 ...